Содержание SL 700

Страница 1: ...der User s Guide SL 700 Be sure to read carefully and follow all the SAFETY INFORMATION on pages i ii iii Keep the manual in a safe place for future reference 15540 Herriman Blvd Noblesville IN 46060 1 800 774 0284 www spycorder com ...

Страница 2: ...esult in a risk of fire or electric shock Overloaded AC outlets extension cords frayed power cords damaged or cracked wire insulation and broken plugs are dangerous They may result in a shock or fire hazard Periodically examine the cord and if its appearance indicates damage or deteriorated insulation have it replaced by your service technician 7 Power Cord Protection Power supply cords should be ...

Страница 3: ...tage or other hazards Refer all servicing to qualified service personnel 18 Conditions Requiring Service Unplug this video product from the wall outlet and refer servicing to qualified service personnel under the following conditions A When the power supply cord or plug is damaged B If liquid has been spilled or objects have fallen into the video product C If the video product has been exposed to ...

Страница 4: ...EC PAUSE REC 3 Playback PLAY 4 Still image STILL 5 Fast forward FF 6 Rewind REW 7 CUE CUE 8 Review REVIEW 9 Slow Pause Still FF Pause Still REW 1 Time Lapse Video Cassette Recorder Front Panel Locations of controls and indicators 1 STOP button 2 REC button 3 REC CHECK button 4 EJECT button 5 CASSETTE LOADING DOOR 6 DISPLAY PANEL 7 PLAY button 8 REW button 9 FF button 10 PAUSE STILL button 11 REMOT...

Страница 5: ...on 9 RMC L indicator RMC L Comes on when the RMC LOCK sw is set to the ON position 10 S REC indicator S REC Comes on when YES is selected in the menu for the series recording 11 R REC indicator R REC Comes on when YES is selected in the menu for the repeat recording 12 SET LOCK SW indicator Comes on when the SET LOCK sw is set to the ON position 13 Mode display TAPE COUNTER display ex 10 HOUR 59 M...

Страница 6: ...ions are not made properly it may cause a fire or damage the equipment 5 Time Lapse Video Cassette Recorder Remote Control 1 POWER TIMER button 2 SHIFT button 3 AUDIO ON button 4 EJECT button 5 SHIFT button 6 SET button 7 SET button 8 REC CHECK button 9 REC button 10 PLAY STILL TRACKING button 11 PLAY STILL TRACKING button 12 PAUSE STILL button 13 PAUSE STILL button 14 FF button 15 STOP button 16 ...

Страница 7: ...tial menu Press the SHIFT button to select the desired item Press the SET or button to set or Press the SHIFT button to select YES or NO Press the MENU button to return to the initial menu If the VCR is in timer recording stand by mode the indicator is displayed on the display panel the on screen displays will not be available First press the Power Timer button to cancel the recording stand by mod...

Страница 8: ...he recording use a flathead screwdriver to break off the erasure prevention tab on the cassette To record again on a tape without erasure prevention tab cover the hole with adhesive tape Erasure prevention tab To prevent accidental erasure remove the tab after recording To record again cover the hole with vinyl tape Loading Place the cassette label side up in the loading slot Gently push the cente...

Страница 9: ... the SHIFT button until the arrow mark points Display set 5 Press the SHIFT button to select Display Set then the DISPLAY SET menu is displayed 6 Press the SET or button to set the minutes ex 30 then press the SHIFT button 7 The seconds are already set to 00 8 Press the SHIFT button 9 Press the SET or button to set the month ex 04 then press the SHIFT button 10 Press the SET or button to set the d...

Страница 10: ...utton during recording The REC and indicators are displayed on the display panel 2 To resume recording press the REC button or press the PAUSE STILL button again SP means to be recorded by SP heads EP means to be recorded by EP heads During pause the image appears on screen but it is not recorded If a recording pause continues for 5 minutes or more the VCR will go into stop mode to avoid damage to...

Страница 11: ...de If the set stop time is earlier than or the same time as the set start time the VCR will consider the stop time to be the following day Program Timer Recording There are two program timer recording methods daily recording or recording on certain days of multiple weeks weekly recording Example 1 To record on every Thursday from 10 00 to 18 00 in 18 hour mode recording speed 1 Make sure that the ...

Страница 12: ...will be flashing on the display panel The VCR internal battery is completely charged after the VCR has been connected to an AC power outlet for 48 hours and it will maintain all the VCR settings memory for up to 30 days Set the timer recordings so that the recording times do not overlap If they do the one with the earliest recording start time will have priority See chart below If the cassette tap...

Страница 13: ...ording Alarm Recording Setting Alarm recording is performed when there is an input trigger at the ALARM IN terminal is displayed on the display panel 1 Make all necessary connections 2 Press the MENU SHIFT SHIFT buttons in sequence to display the REC MODE SET menu 3 Press the SHIFT button until the arrow mark points to Alarm Rec Set 4 Press the SHIFT button to display the ALARM REC SET menu 5 Pres...

Страница 14: ...will start When the tape s end is reached the VCR will rewind it to the beginning regardless of the counter memory and recording will resume If during autorepeat recording there is an alarm trigger is displayed on the display panel and alarm recording will take place Autorepeat recording will continue after alarm recording has completed its programmed duration 3 Press the REC button on VCR No 1 Re...

Страница 15: ...is unstable rolling vertically adjust the tracking control to correct During recording check operations recording is suspended momentarily Normal Playback Normal Playback 1 Turn on the power to the TV monitor 2 Load the video cassette tape 3 Press the REC PLAY SPEED or button to select the playback speed The selected playback speed is displayed on the display panel A tape recorded with EP heads ca...

Страница 16: ...lay returns to the normal screen The VCR will advance or rewind the tape at high speed and playback the first 5 seconds of every normal recording To cancel the index search mode press the STOP button 4 While the desired recording is being played back press the PLAY button Playback will start and index search is cancelled In the index search mode SHIFT button should be used to search forward or in ...

Страница 17: ...ton at the beginning of the desired recording The counter will be reset to 0H 00M 00S on screen The counter will be reset to 0H 00M on the display panel 2 After recording or playback press the Menu button to display the initial MENU 3 Press the SHIFT button to move the arrow mark to Search Select 4 Press the SHIFT button to display the SEARCH SELECT menu The SEARCH SELECT menu is displayed 5 Press...

Страница 18: ...rdings past 35 is erased POWER LOSS the number of power losses and the date and time of the 35 most recent power losses and recoveries are displayed 7 Press the MENU button the normal screen is displayed The setting procedure is now complete Setting the Buzzer 1 Press the MENU button to display the initial MENU 2 Press the SHIFT button to select VCR Mode Set The VCR MODE SET menu is displayed 3 Pr...

Страница 19: ... 0V for 500 msec or more the VCR starts panic recording TAPE END OUT Terminal 1 High During recording when the end of the tape is reached the output becomes DC 5V 2 Low During recording when the end of the tape is reached the output becomes DC 0V Checking Usage Duration 1 Press the MENU button to display the initial MENU Running Time The video heads usage duration 2 Press the MENU button the norma...

Страница 20: ...aged it has to be released before proceeding with the inspection If any problem is discovered during the inspection unplug the power cord and consult your dealer SW OUTPUT Terminal While recording a pulse signal DC 5V is output at the SW OUT terminal after each recording period This terminal is usually connected to the switch input of devices like a camera switching unit or a quad compressor 1 Low...

Страница 21: ...ry the following 1 Unplug the power cord then plug it back in 2 Reset the memory Press the RESET button Under normal conditions do not touch the RESET button 3 If the problem is not corrected after performing steps 1 and 2 consult your dealer Press the RESET button for more than 5 seconds to perform the reset Running Time will not be reset Troubleshooting Guide If the unit does not operate normall...

Страница 22: ...350 lines Color mode 300 lines Audio Input RCA pin jack more than 47kΩ 8 8dBm unbalanced Output RCA pin jack less than 1 5kΩ 7 8dBm unbalanced Microphone input 60 dBs 3 5mm mini jack 10kΩ unbalanced Connectors Alarm input DC 4 5V Open DC 0 0 8V Closed 5 7kΩ Alarm output DC 4 5V H DC 0 0 8V L 5 7kΩ Panic input DC 4 5V Open DC 0 0 8V Closed 5 7kΩ End output DC 4 5V H DC 0 0 8V L 5 7kΩ Warning output...

Страница 23: ...en repaired or altered outside of our factory nor to cases where the serial number thereof has been removed defaced or changed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sale of our electronic products SECURITY LABS INC DOES NOT ASSUME LIABILITY FOR ANY VIOLATION OF PRIVAC...