background image

www.secureaire.com

 | Proudly made in the U.S.A. | AQM-150 Part Number D-001

Operating Guide

Thank you for purchasing the SecureAire AQM-150 Air Quality 
Monitor, the most advanced handheld instrument available 
today. With a large dynamic measuring range that spans from 
0.3 µm to 25.0 µm, with true variable binning for channel size 
adjustment settings to 0.01 µm. The Real-Time Meter function 
is unique in its ability to fine-tune the instrument’s sensitivity 
in order to locate particulate sources with visual and audible 
indications. 

This versatile Air Quality Monitor’s ability to count higher 
than typical particle concentrations allows the Real-Time 
Meter to find point source contamination in cleanrooms  
as well as locating higher particle concentrations being 
generated in many indoor environments. 

Happy Monitoring!

Air  

Purification  

for a Safe, 

Healthy, 

and Clean 

Environment™

AQM-150

Air Quality Monitor

ACTIVE Particle Control Technology  

for Cleaner Air™

Содержание AQM-150

Страница 1: ...unction is unique in its ability to fine tune the instrument s sensitivity in order to locate particulate sources with visual and audible indications This versatile Air Quality Monitor s ability to co...

Страница 2: ...www secureaire com Proudly made in the U S A AQM 150 Operating Guide April 2022 Part Number D 001 2 Preface...

Страница 3: ...les Plus equipment not expressly approved by Particles Plus could void the user s authorization to operate the equipment can risk serious injury and will void all warranties Key to Symbols The symbols...

Страница 4: ...ilter Assembly 0 1 CFM 2 83 LPM AS 99002A Rechargeable Battery 55Wh EE 80003A Temperature RH Probe 32 122 F 0 60 C 1 F 0 5 C 15 90 2 NOTE This probe is optional for 8303 8503 EE 80014A Power Supply 15...

Страница 5: ...tarily starts the pump and begins sampling 2 Pressing the one touch button again for 1 second stops sampling 3 Holding the button for 3 seconds turns the instrument off Prior to starting the instrumen...

Страница 6: ...Green LED on Unit not plugged into AC instrument screen on Battery Charge 10 Red LED blinks every 3 seconds Unit not plugged into AC instrument screen off All LEDs off Operating Instructions Running...

Страница 7: ...ire com Proudly made in the U S A AQM 150 Operating Guide April 2022 Part Number D 001 7 Operating Instructions Clearing Data in AQM 150 The following steps should be followed to clear the data from t...

Страница 8: ...rt on your PC 2 Connect the provided USB cable 6 to AQM 150 and your PC 3 Install setup exe on your PC 4 Open setup exe on your PC 5 Turn AQM 150 on For most efficient operation follow the following s...

Страница 9: ...Operating Instructions 1 Click on Select Columns 2 Click the checkmarks shown in Sect Columns to Display Click Ok 3 Click on Download Data 3a Choose the Record Date Range you wish to download 3b Click...

Страница 10: ...tion session but will only save this information as graph data For the complete data download you must pull the data from the AQM 150 using a USB memory stick or by connecting directly with the USB ca...

Страница 11: ...ture units Celsius or Fahrenheit 10 Sample Time Amount of time set for sample hh mm ss 11 Hold Time Amount of time set for delay before next sample begins hh mm ss 12 Log Scale Turns on feature for va...

Страница 12: ...ysis is performed i e a hospital operating room study Purge Filter Use and Procedure 1 Unscrew the Isokinetic Probe and replace it with the 0 1 micron Purge Filter 2 Run unit until all counts at 0 3u...

Страница 13: ...secureaire com Proudly made in the U S A AQM 150 Operating Guide April 2022 Part Number D 001 13 Appendix A Downloading data from the Real Time Graph Function Selecting Axis Symbol and Color Appendix...

Страница 14: ...www secureaire com Proudly made in the U S A AQM 150 Operating Guide April 2022 Part Number D 001 14 Appendix A Saving File by Name Detailing Test Parameters Fill in...

Страница 15: ...15 Appendix A Running the Test Completing the Test Closing the Test File...

Страница 16: ...n Florida The Company is the industry leader in Active Particle Control which is based upon technologies developed and employed in Semiconductor Cleanrooms SecureAire has advanced and developed highly...

Отзывы: