background image

© 2006 DESA Specialty Products

 

598-1158-01

Requirements

•  The Light Control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 

wired through a switch.

• 

Some  codes  require  installation  by  a  qualified 
electrician.

•  This product is intended for use with the enclosed 

gasket and with a junction box marked for use in wet 
locations.

Model SH-5412

Light Control

Sensor

Cover 

Plate

Lamp Holders

2 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

2 Shells

Features

•  Turns on lighting when motion is detected.
•  Automatically turns lighting off. 
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).

Motion

Sensor Light

Control

Mounting Bolt

Mounting Strap

Plastic 

Hanger

Rubber Plug

Mode: 

On-Time: 

Works:  Day  Night

Test

 

5 Sec 

 

x

Auto

 

1, 5, 10 min. 

 

 

x

Manual

 

Until Dawn* 

 

 

x

OPERATION

* resets to Auto Mode at dawn.

Note:

  When first turned on wait about 1 

1

/

2

 minutes for 

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1

 TEST

10 5 1 

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF 

then...

Put the ON-TIME switch in the 1, 5, 
or 10 minute position.

Put the ON-TIME switch on the bottom 
of the sensor in the TEST position.

Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.

Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.

Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  10 
position.

Move ON-TIME Switch to 

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off 

for one second then 

back on*

MANUAL MODE

AUTO

TEST

*  If you get confused while switching modes, turn the 

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

This package includes:

As an ENERGY STAR

®

 Partner, Heath

®

/Ze-

nith has determined that this product meets 
the ENERGY STAR

®

 guidelines for energy 

efficiency. This product is ENERGY STAR

®

 

compliant when used with 120 Watt bulbs.

Содержание SH-5412

Страница 1: ...de at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10 minute position Put the ON TIME switch on the bottom of the sensor in the TEST position Manual mode only works at night because daylight returns the sensor to AUTO Flipthelightswit...

Страница 2: ...void water damage and electrical shock keep lamp holders 30 below horizontal For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mount Eave Mount For under...

Страница 3: ...ng Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes Range Adjustable DESA Specialty Products reserves the right to dis continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold Maximum Range Maximum Coverage Angle NOTE Sensor has a 1 1 2 minute warm up period before it will detect motion When first tur...

Страница 4: ...ECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIRORREPLACEMENTSHALLBETHESOLEREMEDYOFTHECUSTOMERANDTHERESHALLBENOLIABILITY ON THE PART OF DESA SPECIALTY Products FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORE SEEABLE Some states or provinces do not allow the exclusion o...

Страница 5: ... interruptor de tiempo ON TIME en la posición de 1 5 ó 10 minutos Ponga el interruptor de tiempo ON TIME al fondo del detector en la posición de prueba TEST El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvaloaprenderparaconmutarentre MODO AUTOMATICO y MANUAL El modo manual funciona sólo con el interrupt...

Страница 6: ...be ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Controles Controles Tornillo Sujetador Ajuste los portalámparas aflojando las contratuer cas pero no los gire más de 180 de la calibración hecha en fábrica Cuando atornille los proyectores no los apriete demasiado Mantenga las lámparas por lo menos a 2 5 cm deldetector Nodejeque laslámparasbloquee...

Страница 7: ...ty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad Alcance Máximo Angulo de Cobertura Máxima NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo prenda p...

Страница 8: ...te el día La luz se prende sin ninguna razón aparente POSIBLE CAUSA 1 El interruptor de luz está apaga do 2 El faro está flojo o fundido 3 El fusible está quemado o el cortacircuitos está apagado 4 La desconexión de luz del día estáenefecto Compruébelocu ando comience la obscuridad 5 Alambrado incorrecto si ésta es una nueva instalación 6 No está apuntando correcta mente Apunte de nuevo el detector...

Отзывы: