SECOLink PAS8 Series Скачать руководство пользователя страница 1

Short  wiring  manual 

 basic  information 

Control  Panels  PAS8xx

Control  Panels  PAS8xx

Intruder  alarm  system

SAFETY  WARNINGS

The  device  must  be  installed  in  a  place  with  limited  access.

Please act according to your local rules and do not dispose of your old product with normal household 
waste.

 The product is covered by European Directive   2002/96/EC.

The device must be connected 

to an AC power supply with Protective Earthing: Phase or Live line (L)   black or brown 

cable, Neutral line (N)   blue cable, Protective Earth line (PE)   green cable with a vertical yellow dash. Double 

2

isolated cables with minimum cross-sectional area of   0,75 mm  for 230V power supply must be used.

The device uses two power supplies: main and back-up.


2V, 7Ah/20HR capacity, rechargeable hermetically sealed Lead-Acid battery.

Main power supply: a   power   transformer   with:
         primary winding: ~230V, 50 Hz; 
         secondary winding: ~20V, 1.5A, 50Hz.
Back-up power supply: 1

SecoLink 

intruder

 alarm system   is compliant with the safety requirements of EN 60950-1:2003.

All the above described power supplies linked to the system must 

comply with the EN 60950-1:2003 safety 

requirements.

Additional 

automatic Two-Pole Circuit Breaker

 should be installed in an AC electric power circuit in order to prevent 

over-current and short circuits.
The circuit breaker contact gap should be no less than 3mm.
The circuit breaker should be placed close to the system's housing and should be easily accessed.

Before performing any work of installation or service ALWAYS disconnect the device from power supplies in 
sequence as described below:

  -  cut  off  

230 V

 AC power line with the automatic Two-pole Circuit Breaker

;

  

-  disconnect 

12V back-up battery

 by removing battery female plug from Control Panel male socket BAT.

Two-pole Circuit-Beaker installation on flexible cables is forbidden.

General safety requirements

:

 – do not touch any part of the main power supply under voltage: transformer, a fuse block, connection wires;
 – it is forbidden to perform any device installation or service work during lightning;
 – use batteries according to manufacturer recommendations. The use of improper battery type may cause an 
explosion;
 - battery replacement : be sure battery terminals are isolated, battery terminals short-wiring may cause an explosion.

It is not recommended to connect the device to a fully discharged battery

.   To avoid a malfunction of system   use an 

adequate charger to charge a new or discharged battery before connecting battery   with a device.
Inoperative or expired batteries should be recycled according to the local rules or   EU directives   2006/66/EC   and   
93/86/EEC. 

Waste battery collection and returning for utilization separate from household waste is mandatory

!

Power supply distribution board

Housing of  the  Alarm System (device)

Automatic Two-pole 

Circuir Breaker

L

N

N

L

Cable from power 

distribution board

AC power cable to the 

Alarm System

The Control Panel Terminals TIP, RING, T-

1

, R-1

 should be connected to analog PSTN line. Connection to digital 

ISDN line may cause the device damage.

Page

 1

The device wiring and service should be performed by trained personnel with sufficient knowledge about the device 
and general safety requirements for work with low voltage (up to 1000V) AC power lines. 

In the case of a device 

malfunction repair works can be performed   by qualified personnel only.