Short wiring manual
–
basic information
Control Panels PAS8xx
Control Panels PAS8xx
Intruder alarm system
SAFETY WARNINGS
The device must be installed in a place with limited access.
Please act according to your local rules and do not dispose of your old product with normal household
waste.
The product is covered by European Directive 2002/96/EC.
The device must be connected
–
–
–
to an AC power supply with Protective Earthing: Phase or Live line (L) black or brown
cable, Neutral line (N) blue cable, Protective Earth line (PE) green cable with a vertical yellow dash. Double
2
isolated cables with minimum cross-sectional area of 0,75 mm for 230V power supply must be used.
The device uses two power supplies: main and back-up.
–
–
2V, 7Ah/20HR capacity, rechargeable hermetically sealed Lead-Acid battery.
Main power supply: a power transformer with:
primary winding: ~230V, 50 Hz;
secondary winding: ~20V, 1.5A, 50Hz.
Back-up power supply: 1
SecoLink
intruder
alarm system is compliant with the safety requirements of EN 60950-1:2003.
All the above described power supplies linked to the system must
comply with the EN 60950-1:2003 safety
requirements.
Additional
automatic Two-Pole Circuit Breaker
should be installed in an AC electric power circuit in order to prevent
over-current and short circuits.
The circuit breaker contact gap should be no less than 3mm.
The circuit breaker should be placed close to the system's housing and should be easily accessed.
Before performing any work of installation or service ALWAYS disconnect the device from power supplies in
sequence as described below:
- cut off
230 V
AC power line with the automatic Two-pole Circuit Breaker
;
- disconnect
12V back-up battery
by removing battery female plug from Control Panel male socket BAT.
Two-pole Circuit-Beaker installation on flexible cables is forbidden.
General safety requirements
:
– do not touch any part of the main power supply under voltage: transformer, a fuse block, connection wires;
– it is forbidden to perform any device installation or service work during lightning;
– use batteries according to manufacturer recommendations. The use of improper battery type may cause an
explosion;
- battery replacement : be sure battery terminals are isolated, battery terminals short-wiring may cause an explosion.
It is not recommended to connect the device to a fully discharged battery
. To avoid a malfunction of system use an
adequate charger to charge a new or discharged battery before connecting battery with a device.
Inoperative or expired batteries should be recycled according to the local rules or EU directives 2006/66/EC and
93/86/EEC.
Waste battery collection and returning for utilization separate from household waste is mandatory
!
Power supply distribution board
Housing of the Alarm System (device)
Automatic Two-pole
Circuir Breaker
L
N
N
L
Cable from power
distribution board
AC power cable to the
Alarm System
The Control Panel Terminals TIP, RING, T-
1
, R-1
should be connected to analog PSTN line. Connection to digital
ISDN line may cause the device damage.
Page
1
The device wiring and service should be performed by trained personnel with sufficient knowledge about the device
and general safety requirements for work with low voltage (up to 1000V) AC power lines.
In the case of a device
malfunction repair works can be performed by qualified personnel only.