Z01 Door
Belongs to partition
1
5
Each zone must be assigned to a partition. All zones are assigned to
the
1st partition by default.
Z01 Door
Definition
Entry/Exit
6
Setting the zone definition is partly determined by the arming mode:
Entry/Exit
- used for Entry/Exit doors. A zone must be closed during arming and when the delay expires.
Entry delay will be available when
the
system is armed in
Away
or
Stay
mode.
Interior -
usually assigned to motion detectors and to interior doors. Violation of this zone will not trigger an
alarm when
the
system is armed in
Night
or
Stay
mode.
Perimeter
or
Instant
- usually intended for non-exit/entry doors, window protection, shock detection, and
motion detectors. A zone goes immediately into an alarm state when violated while armed.
24h Burglary
- a violation of such a zone causes an instant intrusion alarm, regardless of the system’s state.
24h Panic Silent
- used for external panic buttons. If violated, an immediate panic alarm is triggered, with the
exception that there is no audible indication of the violation.
24h Panic Audible
- same as
Panic Silent
,
except that the alarm will be audible.
24h Tamper -
the tamper function is continuously operational. When a
24h tamper
zone is activated, a
tamper alarm is generated.
24h Fire
or
24h Smoke -
for smoke or other types of fire detectors. To avoid false alarms, zone attribute
Fire
Verification
is recommended to use.
24h Fire button
- for external auxiliary emergency alert buttons. If violated, an immediate fire alarm will
sound, regardless of the system’s state.
24h Medical button -
for external auxiliary emergency alert buttons. If violated, an immediate medical alarm
will sound, regardless of the system’s state.
24h Fire supervisory
,
24h Low Water Level
,
24h RF Jam
,
24h Gas Detected
,
24h Water leakage
,
24h High
Temperature, 24h Low Temperature -
this group of definitions is used for
the
24h technical zones to report about
abnormalities in the environment.
Control
-
z
one is mostly used to arm/disarm the system (
Key-switch
zone). Momentary and maintained key-
switch arming are available. This definition can also be used to turn On / Off the PGM output. Violation of this
zone will not trigger an alarm, regardless of the system’s state.
Follower -
usually assigned to motion detectors and to interior doors protecting the area between entry door
and the keypad. This zone(s) causes an immediate intrusion alarm when violated unless an
Entry/Exit
zone was
violated first. Violation of this zone will not trigger an alarm when the system is armed in
Night
or
Stay
mode.
Follower Night Armed
- this zone is the same as the
Follower
zone, but violation of this zone will not trigger
an alarm when the system is armed in
Stay
mode.
Interior Night Armed -
this zone is the same as the
Interior
zone, but violation of this zone will not trigger an
alarm when the system is armed
in
Stay
mode.
Entry/Exit Forced
- same as
Entry/Exit
zone but unlike a regular entry/exit zone this zone can be violated
before the arming.
Short programming manual - basic information
Intruder alarm system
System with
KM24, KM24A
, KM24G keypads
Z01 Door
Supervisory window
2h
6
Specifies how often the system checks for supervision signals, identifying each of the system’s wireless
detectors. The system generates a local trouble signal identifying the zone of any wireless detectors from which
a signal is not received during the specified interval. Control panel then sends the supervision report code to the
CMS.
Note:
0 hours disables the supervision. If there are many detectors in the system, due to increased
collision effect, it is recommended to set the supervision time to a minimum of 2 hours.
Z01 Door
Zone speed
0,4 sec
7
The loop speed menu enables you to set different times for which zone violation must exist before the zone will
trigger an alarm condition. Normally zone speed is within 0,1 - 2,5 seconds range. With
Vibration
zone loop type
selected, the zone speed must be within 0,01 - 0,25 seconds range (fast zone). This zone loop speed time can
be defined only for zones located on the control panel.
Z01 Door
Entry Delay
30 sec
8
Used for
Entry/Exit
or
Entry/Exit Forced
zones. Entry delay time is programmable within 1 - 255 seconds range.
Z01 Door
Enable Bypass
Yes
9
This attribute permits zone bypassing by authorized system users. If
No
is displayed as an option, then the zone
cannot be manually bypassed.
Z01 Door
No alarm
No
9
Used for
24h High temperature
or
24h Low temperature
. A zone with this attribute will not trigger an alarm, but
can start PGM action.
Z01 Door
Arm on exit
No
11
This attribute is only used for
Entry/Exit
or
Entry/Exit Forced
. With this attribute being set - the system will finish
an exit delay countdown and will arm the system immediately after the entrance door will close.
Z01 Door
Exit Route
No
11
With this attribute being set - a zone with
Interior
definition can be violated during an exit delay.
Z01 Door
Entry Route
No
10
With this attribute being set - a zone with
Interior
definition can be violated during an entry delay.
Z01 Door
Fire verification
No
10
This attribute is used in fire (smoke) verification procedure. Power to the smoke detector(s) in the affected zone
will cut off and then restore. If a subsequent detection occurs in the same zone within a predefined time of the
first detection, the system will emit a fire alarm. It’s recommended to use +PGM as fire detector power supply.
Z01 Door
Limit alarms
Yes
13
Repeated violation of the same zone, often resulting in a false alarm and usually arising due to a malfunction, an
environmental problem, or incorrect installation of a detector or sensor. By default,
the
system is set to make a
Used for
24h High temperature
or
24h Low temperature.
Enter the temperature. Use
[
]
or [
‚
]
to change
temperature sign (+ or -).
Note:
temperature field will be visible if wireless detector is in use.
Z01 Door
Temperature
+30 C
9