Intruder alarm system

System with  

KM24, KM24A

, KM24G keypads

Page 13

SERVICE MODE MENU TREE

 

Service 

M

ode

 Modules 

 Module settings

   Basic settings:
     Name
     Address 
     Type 
     Serial No.
     Use Module Tamper
   Control panel settings:
     PGM load detection
     Cut - off +BELL
     Cut - off -PGM(1)
     Cut - off +PGM(2)
     Arm anyway
   Keypad settings:
     Assigned partitions
     Fire alarm
     Medical alarm
     Panic alarm
     Panic silent
   PROX8 settings:
     Assigned partitions
     Installation
     Preferred mode
     Second mode
     Third mode
     Fourth mode
     Sound
     Hide LED indication
     Unknown tag
     Operation mode
   EXT116S(VM) settings:
     MC & IR Anti-sabotage
     Roller Anti-sabotage

 Automatic registration

 Manual registration

 Partitions

 Zones

 PGM Outputs

 System times

 System Setup

 Report settings

 PSTN Communicator

   Reporting
   Account number

   Reporting
   Tel. Number 1
   Tel. Number 2
   Tel. Number 3
   Tel. Number 4
   Account number
   Dials In Session
   Sessions
   Pause Btw Sessions 
   Dial Tone Test
   Method
   Line Monitoring
   Line Loss Delay
   Rings to answer
   Double call timer

 SERIAL Interface

 GPRS settings

 LAN settings

   Receiver No.1
    Use GPRS as backup
     Address
     Port
     Account number
     Protocol
     Transport
   Receiver No.2
    Use as backup for Rec.1
     Address
     Port
     Use same Acc. as Rec.1
     Account number
     Protocol
     Transport
   APN
     User name
     Password
   Periodic test
     Send every

   Receiver No.1
     Address
     Port
     Use SERIAL account
     Account number
     Protocol
     Transport
   Receiver No.2
     

Use as backup for Rec.1

     Address
     Port
     Use SERIAL account
     Account number
     Protocol
     Transport
   Periodic test
     Send every
   Obtain IP automatic.
     IP address
     Subnet mask
     Gateway
   Obtain DNS automatic.
     DNS server 1
     DNS server 2

Periodic Test Settings

   Period in hours
   Period in days
   Period time (hh:mm)

   Name
   In Use
   Exit Delay
   No Entry Delay
   Arming timer
   Pre-alarm timer

   Name
   Address
   Loop type
   Serial No.
  Model
  Loop (zone)
  Use tamper
   

Operation code

   Belongs to partition
   Definition
   Zone speed
   Supervisory window
   Temperature
   Enable bypass
   Arm on exit
   Armed in Night
   Fire Verification
   Entry Route
   Exit Route
   Limit alarms
   Limit reports
   Pre-alarm
   Voice menu

   Name
   Address
   Definition
   From zones
   From modules
   From partitions
   From timers
   Pulse length
   Inversion of status
   Pulse
   Latch
   Pre-alarm
   Fail to Arm Notific.
   Arm Notification
   Disarm Notification

   Exit delay (PAS808M)
   KM24 Alarm Time
   Auto Arm Delay
   Pre-Alarm time
   AC Loss Rep. Delay
   Detector Settle Time
   Fire Verific. Time
   Immediate entry alarm

 Security Settings

   Arm with PIN
   Pre-alarm with PIN
   Bypass with PIN
   Sys. summary PIN req.
   PIN resetting
   Duress code

 Project Loading

 Set Language

 Unregister Modules

 Start connection with PC

 From CP to KM24

 From KM24 to CP

 Restore Project

   Restore Main Settings
   Restore Default Project

 Unregister keypad

   

English

Short  programming manual - basic information 

Rev.15/03/21_KF_Sert

 Wireless Subsystem

   

Security grade

   

Mode

   

Frequency

   Attenuation

Содержание BK4

Страница 1: ... the tab Project data sending receiving 3 Once you customize the predefined template you can use it to program an individual system or thousands of systems 4 DO NOT FORGET to upload the customized template further project back to the keypad use the tab Project data sending receiving Fig 1 USB connection Upon power up of the system the keypad will display a phrase First Start Press ENT It means tha...

Страница 2: ... the customized project back to the keypad use the tab Project data sending receiving MANUAL REGISTRATION OF MODULES Control panel PAS808M supports up to 7 modules and control panels PAS816 PAS832 P16 P32 P64 supports up to 15 modules If there are a few modules with incl enabled virtual modules EXT116VM on P series control panels the same default addresses in the system for example several EXM800 ...

Страница 3: ...s are programmed in the system program system timers in menu Main menu Settings Timers M00 Control Panel 1 Name Control Panel It is recommended to give an appropriate name to the module The module name will appear on keypad s LCD if there will be any trouble with the module 2 M00 Control Panel Address 00 Registered module address is shown in a second row and on the upper left corner of LCD eg M00 ...

Страница 4: ... MC and IR Anti Sabotage Roller Anti Sabotage No 5 6 M06 PROX8 Unknown tag No actio 13 The proximity reader has 3 options on what it must do when the unknown proximity tag is detected No action Indication module starts blinking red and starts emitting an annoying noise Indication and alarm module starts blinking red and starts emitting an annoying noise The alarm siren will be triggered after 3 at...

Страница 5: ...e Roller special purpose zone loop type exluding PAS808M Wireless Z01 Door Address 00_1 A 2 Z01 Door Address 00_1 B 2 Page 5 Wireless detectors can be enrolled using serial number in a system with following firmware version or higher control panel P16 P32 P64 v 5 00 wireless zone expansion module EXT116S v 5 000 keypads KM24 KM24Aarba KM24G v 5 000 keypads KM25 v 5 000 software MASCAD v 1 9403 GSM...

Страница 6: ...m is armed in Stay mode Entry Exit Forced same as Entry Exit zone but unlike a regular entry exit zone this zone can be violated before the arming Short programming manual basic information Intruder alarm system System with KM24 KM24A KM24G keypads Z01 Door Supervisory window 2h 6 Specifies how often the system checks for supervision signals identifying each of the system s wireless detectors The ...

Страница 7: ...tput triggering source otherwise the PGM will not work correctly Not used unused PGM output should be programmed as Not Used FireAlarm output activates if an alarm occurs on the selected zone or module emergency keys Fire Burglary Alarm output activates if fire or burglary alarm occurs on the selected zone or module emergency keys Note output also activates when zone or module tamper conditions ar...

Страница 8: ...eporting to CMS or to the user via the PSTN line PSTN Communicator Tel Number 1 8p45345464 2 Program the phone numbers as required Use the key to enter additional symbols p 3 sec pause P 10 sec pause w wait dial tone User must acknowledge the call by pressing the Ü key on the phone otherwise the control panel will call again Program the Account number This account number will be used for all repor...

Страница 9: ...twork and another computer network frequently the public Internet A GSM GPRS module making a data connection must be configured with an APN to present to the network provider Contact your provider to verify the correct APN settings 4 GPRS settings Yes Send every 15 sec Periodic test The Periodic test menu enables you to set the time period that the module will automatically send a test report to t...

Страница 10: ...in hours Period in hours Report time hh mm Report time hh mm x 1 1 x 01 00 xx 15 1 1 2 2 3 3 The programmed exit delay will be applied for all enabled partitions System Times Exit Delay 30 sec 1 Used for all partitions An audible Auto Arm Delay warning countdown will commence prior the automatic arming User that has right to stop auto arming can enter a valid PIN code at any time during the countd...

Страница 11: ...stribution the wireless devices detectors PGM outputs and remote control can be programmed at factory to operate on different frequency Receiver can receive a signal from transmitter when operating frequency matches Wireless Subsystem 4 Attenuation 0 dB Due to the fact that there may be changes in the passive environment after installation it is possible to temporarily for 3dB attenuate the radio ...

Страница 12: ... from the user U01 User 01 U01 User 01 Rights Arm Disarm Yes Clear alarm Yes Abort arming Yes All Rights Selected 7 7 All system users have all rights assigned by default However it is possible to change them The user has access to the following Arm Disarm Clear alarm Abort arming Bypass zones Edit settings View Event log Test fire zones Reporting test Run other tests Control PGM outputs Edit syst...

Страница 13: ...GISTER KEYPAD KM24G PROGRAMMING WIZARD KM24G Service Mode Unregister Modules Service Mode Unregister keypad Service Mode Programming Wizard Used to unregister system modules The message First Start Press ENT will appear on keypad s LCD screen when this procedure will end Used to unregister the keypad from the system Step by step programming wizzard with explanations and wiring schemes 5 7 6 Servic...

Страница 14: ...Use SERIALaccount Account number Protocol Transport Receiver No 2 Use as backup for Rec 1 Address Port Use SERIALaccount Account number Protocol Transport Periodic test Send every Obtain IPautomatic IPaddress Subnet mask Gateway Obtain DNS automatic DNS server 1 DNS server 2 Periodic Test Settings Period in hours Period in days Period time hh mm Name In Use Exit Delay No Entry Delay Arming timer P...

Отзывы: