9. Testing Data
a) Solenoid resistance table
Voltage: 230V, 50Hz
Tolerance: +/- 10%
SLL-20 & 30 models: Solenoids are in series connection
Other models: Solenoids are in parallel connection
Total R
Single R
SLL-40
86.5
173.0
SLL-50
60.8
121.7
EL-60
36.7
73.4
EL-80-15
21.9
43.7
EL-80-17
33.1
66.2
EL-100
20.0
40.0
EL-120W
16.2
64.7
EL-150
16.6
66.2
EL-200
10.0
40.0
10. Spare Part Kits
Only use genuine SECOH replacement parts. Non-standard parts will have a
detrimental effect on overall pump life and performance.
In order to ensure long service and operation, it is recommended diaphragms
and valve boxes are replaced once a year.
All
parts; magnets, filters, service kits and diaphragms are available from
www.partsandpumps.co.uk
online site and can be despatched immediately.
We also stock a complete range of Secoh pumps for replacement purposes
and these can also be used to replace defective pumps of other brands with