SECO-LARM ENFORCER E-9626-2B190Q Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

Long-Range Barrier Sensors

 

Manual 

 
 

Model 

# of Beams 

Length 

E-9626-2B190Q 

2 pairs 

26” (66cm) 

E-9643-4B190Q 

4 pairs 

43” (109cm) 

E-9661-6B190Q 

6 pairs 

61” (155cm) 

E-9679-8B190Q 

8 pairs 

79” (201cm) 

 

 

4 Different programmable frequencies 

 

Range: Up to 190ft (60m) outdoor, 

380ft (120m) indoor 

 

End caps swivel for easy installation 

 

Built-in heater for cold weather 
operation 

Note:  Model numbers that end with “Q” or that have a round green “Q” sticker signify RoHS-compliant products. 

 

Built-in tamper switches 

 

Programmable trigger options 

 

Form C relay output 

 

Weatherproof IP65 

 

AGC circuits ensure operation in rain, 
fog, and low-temperature conditions 

Содержание ENFORCER E-9626-2B190Q

Страница 1: ...quencies Range Up to 190ft 60m outdoor 380ft 120m indoor End caps swivel for easy installation Built in heater for cold weather operation Note Model numbers that end with Q or that have a round green...

Страница 2: ...lp prevent false alarms Installation and alignment is quick and easy with the ENFORCER Long Range Barrier Sensors They come with swiveling heads that allow them to be mounted along the same wall or on...

Страница 3: ...ating temperature 45OC 55OC 49OF 131OF Humidity 95 Ingress protection IP65 Case Aluminum housing PC anti UV cover ABS end caps Dimensions See page 4 Dimensions for more details Weight Tx Rx with brack...

Страница 4: ...2B190Q E 9643 4B190Q E 9661 6B190Q E 9679 8B190Q Swivel Housing Each sensor is built with a swivel housing for flexible installations and simple alignment To use twist the beams up to 90 Sample Appli...

Страница 5: ...ection switch SW2 Tamper switch Rubber wire hole Tamper switch Rubber wire hole Beam alignment buzzer jumper JP1 Response time switch SW1 Channel selection switch SW2 Tamper switch Power Ground Tamper...

Страница 6: ...way that the terminal block of one unit is at the top and the other is at the bottom see Fig 3 Do not mount where animals or other objects could accidentally break the beams Do not mount near reflect...

Страница 7: ...X CH 1 RX CH 4 RX CH 3 TX Installation Wall vs Pole Mounting Fig 6 Pole mounting Fig 4 Wall mounting Same wall Fig 5 Wall mounting Facing walls Fig 7 Linear protection CH1 CH1 TX RX CH3 CH3 TX RX CH2...

Страница 8: ...rs of the end caps and locate the three mounting holes see Fig 10 Using these holes as a template mark their location on the wall with a pencil 4 Connect the wires see pg 9 before permanently mounting...

Страница 9: ...st be off when aligning the sensor 5 Use a screwdriver to tighten the screws holding the end cap in place Receiver 1 Unscrew and pull the end cap off the side of the transmitter with the terminal bloc...

Страница 10: ...ill sound To disable this feature remove JP1 see Fig 14 3 Once the beams are aligned the red LED will turn off and the buzzer will not sound Programming the Trigger Mode 1 The default detection method...

Страница 11: ...r Sensor Fig 17 Programming the response time SW1 300ms 450ms 600ms 150ms Receiver circuit board Triggering the Barrier Sensor Fig 19 Ways to trigger the sensor Any single pair tripped Response time 2...

Страница 12: ...RM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2012 SECO LARM U S A Inc All rights reserved This materi...

Отзывы: