SecEng SED-VTI Скачать руководство пользователя страница 1

SED-VTI 

August 2017,  V031 

  
  

Virtual Telephone Interface 

Installation & User Manual 

  

WARNING:  PLEASE READ 

INSTALLATION INSTRUCTIONS 

FIRST 

  

  

  
PRODUCT  WARRANTY 

This product is covered by a 12 month, back to base warranty from 
date of purchase and proof of purchase should be supplied. The 
warranty does not cover damage that has resulted from the 
improper installation or improper use of this product. The warranty 
does not cover lightning damage, product misuse, electrical surges 
or acts of God. 

  
LIMITATION OF LIABILITY 

Sec-Eng Systems Pty Ltd does not accept any liability for the loss 
or damage to property or persons in relation to goods supplied. 
This disclaimer is only limited to the warranty of the goods supplied 
and the intended use. 

  
NOTE: THIS MANUAL IS SUBJECT TO COPYRIGHT 

Содержание SED-VTI

Страница 1: ...does not cover damage that has resulted from the improper installation or improper use of this product The warranty does not cover lightning damage product misuse electrical surges or acts of God LIM...

Страница 2: ...tting into the SED VTI ensure that the SIM is active and not pin locked This may require the SIM to be tested in a mobile phone first Warning Ensure you have the correct PIN number Entering the wrong...

Страница 3: ...ready the P LED should be on constant not flashing and LEDs 1 5 indicating the signal strength minimum of 2 bars is required 6 Connect the phone lead from the panel to the RJ connector on the SED VTI...

Страница 4: ...e Note If the SED VTI cannot connect to the network after a number of attempts it will reboot and reset the LEDs When system is not connecting to network F 3 check the following SIM card is active not...

Страница 5: ...SMS nil System Features 20 GPRS CID RX convertor 0 21 GPRS CID TX convertor 0 32 Internal CID RX kiss off time 1 9 sec 2 33 Digital volume RX adjustment 1 9 5 34 Digital volume TX adjustment 1 9 5 42...

Страница 6: ...format Function new value Example To set function 01 to 4321 the SMS command is 014321 Self Test Setup The SED VTI has a built in self test dialer which can send periodic Contact ID reports to a recei...

Страница 7: ...S interface RJ11 Antenna connector SMA Female Antenna supplied 3dBi Omni directional Modem UBLOX Lisa U200 Network Connectivity Penta Band GSM 3G 800 850 900 1700 1900 2100MHz Certification PTCRB GCF...