1.1 Introduction
K3-3 is a standalone, convertible integrated reader and access control. 
It controls electronic lock, exit button, and the magnetic contact switch 
on the door. If the unit is connected to a standard access control unit, 
then it functions as a reader. The unit accepts up to 500 users, allow 
entry via a 4-6 digits PIN and/or by presenting a proximity EM card. 

1. Introduction, Features and Specifications

2.Installation and Wiring Instructions

Electronic lock schematic diagram

 Wiring diagram (DC 12V power supply)            

Wiring diagram (special power supply for access control)

Red

Black Green White Brown Yellow Orange Blue

Red Black Green White Brown Yellow Orange Blue

K3-3 Standalone Access Control

K3-3 Standalone Access Control

3. Wiring Definition  

+12V DC

GND

D0

D1

Functionality

Buzzer

Red            

Black         

Green        

White         

Color

Brown

 

Yellow

Description

LED

+12V Power Input

GND
Wiegand output D0

Wiegand output D1

Green light input

Buzzer input

4. Master keypad Operation

Enter Master Operation Mode. It will return to normal mode if 
there is no right Master PIN input in 5 seconds. After input of right 
master PIN, it will also return to normal mode if there is no valid 
operation in 30 seconds. Press “#” to confirm the input number, 
return to previous menu by press “*”, the LED will indicate the 
operation mode. 

E

xit 

B

u

tto

n

D

o

o

C

o

n

ta

ct

B

 

Lock

special power supply

Remark:

 

8 digits card number, such as 118,32319, some cards has no 

    mark of the first 3 digits 118, remains 32319. It requires to add 
    card by read card, adding cards by input card number is not 
    acceptable;10 digits card number, such as 0007765567, some 
    cards has no mark of the first 3 digits 000, remains 7765567, 
    requires to input 10 digits 0007765567 by add 000 before 
    7765567.

 

A PIN 1234 is added for a card, it can not be used to unlock the 

    lock, can be used to change PIN. 

 

After one card is added , you can continue to add other cards 

    or PIN without exiting the mode. 

 

Type A electronic lock: Fail Secure lock(Unlock when power 

    on), such as Electronic Controlling Lock.

 Type B electronic lock: Fail Safe lock(Unlock when power off), 

    such as EM Lock, Electronic Bolt Lock, etc. 

Master Operation

Red

Flash Red

Function

6-8 digits master PIN

#

Master mode
(default 888888)

Access control mode settings

Flash 
Red

Function

Red and Green LED ON

6-8digits new PIN, #,
repeat 6-8digits new PIN, #

Change 
master PIN

Read card
1-500 (ID) , #, Read card

Add one card

or add more than 
1 cards

8 or 10 digits card number

,

1-500 (ID) , #, 8 or 10 digits card 
number, #

1-500 (ID) , #, 4-6 digits user 
PIN, #

Add one user PIN, 
or add more than 
1 users PIN

Read card

8 or 10 digits card number, #

1-500 (ID) , #

Delete one card, 
or delete more 
than 1 cards

Delete one user, 
or delete more 
than one users 

2

0000, #

Delete all users 
and PIN

0, #

1, #

2, #

To unlock by card

To unlock by 
card and PIN

To unlock by card 
or PIN (default)

3

1-99, #

Lock strike release 
time: 50mS

0, #

Lock strike release 
time:1-99S (default 
5S)

4

Type A electronic 
lock

Type B electronic
lock 

  (default)

0, #

1, #

5

Reader mode settings

Flash 
Red

Flash 
Red and 
Green

Red 
Green

Function

0, #
1, #

7

1

3

Reader mode
Access control mode  (default)
4-6 digits key press sends card 
number

0, #

Each key press sends 4bit output 
data (default)

1, #

Each key press sends 8bit output 
data

2, #

5. User Settings

5.1  To unlock the door for card users, 
Read valid card once, the electronic lock will unlock
5.2  To unlock the door for card and PIN users
Read valid card once then enter 4-6 digits PIN#, the lock will unlock
5.3  To unlock the door for card or PIN users
Read valid card once, the lock will unlock
Or enter 4-6 digits PIN#, the lock will unlock

5.4 To change the PIN of a PIN user
*, Read Card, input 4-6 digits old PIN , #, input 4-6 digits new PIN, 
#, repeat input 4-6 digits new PIN, #

.

or*, Input 1-500 (ID), #, input 4-6 digits old PIN, #, input 4-6 digits 
new PIN, #, repeat input 4-6 digits new PIN, #

.

Remark: For PIN users without card, must get ID number and 
initial PIN from the master. For users with card, must read card to 
change initial PIN.

6. Alarm

6.1 Anti Tamper Alarm
While anti-tamper function is valid, if the access control unit is 
removed from the cover, the buzzer alarm will activate.

6.2 Magnetic Contact Switch on the Door 
While connecting to a door position switch, if door-forced 
conditions are supported, the buzzer alarm will activate if the 
door is forced open..

6.3 Remove the alarm
While anti-tamper and door status alarm is valid, read valid card, 
or input master code can remove the alarm. The alarm will also 
stop after 1 min if there is no operation.

Power off, press *, power on, the red and green LED will turn on, 
release it until hear two beeps, then will hear one beep and the 
red LED will turn on, resets to factory default setting is done.

Reset to factory default, the users' information is still retained.

7. Reset to Factory Default

8. Sound and Light Indication

Red LED

Green LED

Operation Status

Buzzer

Standby

Card & PIN inputting

Slow flash

3 Short Ring

OFF

OFF

Press Key

Read Card
Door Open
Operation Successful
Operation failed
PIN Inputting

1st menu
2nd menu
Under Setting 

Alarm

ON

OFF
OFF

ON
ON
ON

OFF

Slow flash
Slow flash
Slow flash

OFF
OFF

ON

ON

OFF

Quick flash

Long Ring

Long Ring

Long Ring

Short Ring

Alarm

9. Reader Application (wiring diagram)

+

1

2

V

G

N

D

D

0

D

1

D_IN(LED)

OPEN(BZ)

LOCK+

LOCK-

Red

Black Green White Brown Yellow Orange Blue

Reader Mode

+

12V GND

D0

D1

LED

BZ

Access Control

Set the unit to reader application, functions as below:

The wire in green (D0) is the wire for Wiegand 0, and the wire 
in white is the wire for wiegand 1. The pulse width for low voltage 
is 40uS; and the time interval is 2mS. 

There are 3 formats for the card output by Wiegand 26. 
Format 0: 4-6 digits key press sends card number format: Input 
4-6 digits PIN, press “#”, output a Wiegand 26, 10-bit decimal 
card number. For example, input password 999999, the output 
card number is 0000999999, could be displayed by 10-bit 
decimal card number display equipment.

Format 1: Each key press sends 4 bits data, the corresponding 
relationship is:

1    (0001) ,    2 (0010) ,     3 (0011)
4    (0100) ,    5 (0101) ,     6 (0110)
7    (0111) ,    8 (1000) ,     9 (1001)
*     (1010) ,   0 (0000) ,     # (1011)

Format 2: Each key press sends 8bit output data, the first 4 digits 
is ones-complement code for the last 4 digits, the corresponding 
relationship is:

1    (11100001) ,     2 (11010010) ,     3 (11000011)
4    (10110100) ,     5 (10100101) ,     6 (10010110)
7    (10000111) ,     8 (01111000) ,     9 (01101001)
*     (01011010) ,    0 (11110000) ,     # (01001011)

2mS

+5V

+5V

D0

D1

0V

0V

40uS

40uS

2mS

1.2 Features
Backlit keypad,  multi-function, operating as access control or card 
reader, suitable for various occasions.

1.3 Specifications
> Operating voltage range: DC12-24V
> Static input current: 

20mA

> Max proximity card read range: 5-8cm
> Excitation Frequency: 125KHz
> Card transmit format: Wiegand 26
> Keypad transmit format: 4-6 digits key press to output card number 
   format. Each press outputs a 4 bits or 8 bits data.
> Size (Height×Width×Depth): 90×60×27mm
> Operating temperature range: -40

60° C

> Operating humidity: 0

95% 

(

non-condensing)

Slow flash