Seaward CROPICO DO7010 Скачать руководство пользователя страница 1

Digital Microhmmeter
Type DO7010

Operating Instructions

Bracken Hill, South West Industrial Estate,
Peterlee, Co. Durham SR8 2SW. England.
Tel: +44 (0)191-586 3511  Fax: +44 (0)191-586 0227
www.cropico.co.uk
[email protected]

Содержание CROPICO DO7010

Страница 1: ...Microhmmeter Type DO7010 Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW England Tel 44 0 191 586 3511 Fax 44 0 191 586 0227 www cropico co uk sales cropic...

Страница 2: ...m or manner either electronically mechanically by photocopying recording or in any manner without prior written consent from CROPICO This also applies to accompanying drawings and diagrams Due to a po...

Страница 3: ...ed by the European Directive 2002 96 EC Please familiarise yourself with the appropriate local separate collection system for electrical and electronic products Please dispose of this product accordin...

Страница 4: ...SECTION 3 DO7010 CONFIGURATION 22 3 1 LCD screen setup the contrast 23 3 2 LCD screen setup the backlight 23 3 3 Auto switch off mode 24 3 4 Keys sound level 24 3 5 Alarm sound level 25 3 6 Measuremen...

Страница 5: ...election 36 5 2 Measurement protocol header display 37 5 3 First measurement of the protocol 37 5 3 1 Example of a PASS measurement 38 5 3 2 Direct access to a test step 38 5 3 3 Example of a FAIL mea...

Страница 6: ...en the supplied accessories are used The measurement probes can include limitation or protective elements therefore it is forbidden to modify without written In case of use under other conditions than...

Страница 7: ...and measurement results on a PC under excel format files RS232 serial interface to download data between the DO7010 and a PC Remote Control Unit with LCD display similar to the DO7010 main unit displ...

Страница 8: ...charge level error code measurement polarity Keyboard 5 function keys changing according to the menus 4 navigation keys arrows UP DOWN RIGHT LEFT 1 data enter key 1 software power ON key 1 mechanical...

Страница 9: ...LCD screen 1 microprocessor and an error message is displayed if the current is out of specs 10 Each measurement range can be operated with 2 currents high and low currents 100 selected by the operato...

Страница 10: ...even when the main battery pack is fully discharged and when replacing the battery pack The keyboard allows you to quickly select the functions search for the points to be measured scrolling the scre...

Страница 11: ...volts The charge control is fully automatic and the charge time is less or equal to 3 hours Additional battery packs can be purchased separately DO7010 02 1 2 8 Unit Dimensions High Length 340mm Widt...

Страница 12: ...0 mm Weight 600 g Display 64x240 points LCD matrix liquid crystal display with electroluminescent diode backlight 6000 digit measurement and location test point display in large and small characters f...

Страница 13: ...er the connection cable between the DO7010 and the RCU can be disconnected on the RCU side The operator brings the RCU to the data storage PC computer equipped with the DO7010 08 option RCU PC adaptor...

Страница 14: ...10 unit Then the operator brings the DO7010 into the production area and executes all the measurements When the measurement protocol complete or partial is over the operator brings the DO7010 to the d...

Страница 15: ...emote DO7010 15 pin female Quick lock DO7010 179A DO7010 08 DO7010 262 DO7010 REM DO7010 REM 1 2 12 Wiring schematic between PC DO7010 and DO7010 REM 9 pin male 9 pin female 9 pin male 9 pin female Op...

Страница 16: ...Jaeger adaptor 3 pins male to 4 pins female DO7010 15 Protection lid DO7010 16 Bag for accessories DO7010 17 Shunt 1 m 0 5 for DO7010 DO7010 18 Shunt 5 m 0 5 for DO7010 DO7010 19 Shunt 10 m 0 5 for D...

Страница 17: ...nder test 2 wires are used to measure the voltage difference directly on the specimen under test terminals With this method the measurement leads resistance doesn t introduce error but should not exce...

Страница 18: ...ging in the DO7010 Switch OFF the DO7010 with the ON OFF key left hand side on the front panel Connect the charger circular connector in the front panel battery pack terminal named CHARGER Connect the...

Страница 19: ...e charge end 3 hours Then disconnect the circular connector from the DO7010 front panel Switch ON the DO7010 and check that the battery level gives a value 99 2 2 Accessories connection The DO7010 acc...

Страница 20: ...to modify parameters DISPLAY ON AUTO OFF 20 MINS KEY BEEP HI BEEPER HI TRIGGER AUTO DATE 29 03 04 TIME 12 13 LANG ENG ESC 80 DO7010 MANUAL SEQU TEST SETUP With the RIGHT arrow or the enter key enter...

Страница 21: ...mode with the UP and DOWN arrows OFF without backlight AUTO set the backlight time from 5 to 60 seconds by 5 sec steps with the RIGHT then UP and DOWN arrows key DISPLAY CONTRAST OFF AUTO OFF BACKLIGH...

Страница 22: ...FF no sound when pressing a key LO low sound level HI high sound level DISPLAY OFF AUTO OFF LO KEY BEEP HI BEEPER TRIGGER DATE TIME LANG ESC DISPLAY OFF AUTO OFF ON 20 MINS KEY BEEP BEEPER TRIGGER DAT...

Страница 23: ...utton MEASURE AUTO automatic measurement trigger by detection of 100mA current flowing through the specimen under test then current pulse according to the current setup DISPLAY MAN AUTO OFF AUTO KEY B...

Страница 24: ...enter key Set the Hour with the UP and DOWN arrows Move to the Minute field with RIGHT arrow Set the Minute with the UP and DOWN arrows DISPLAY ON AUTO OFF 20 MINS KEY BEEP HI BEEPER HI TRIGGER AUTO...

Страница 25: ...ility with the UP and DOWN arrows 60HZ for 60Hz TRIGGER 50 HZ DATE 60 HZ TIME LANG MAINS VERSION PASSCODE CAL DISPLAY ENG AUTO OFF FRA KEY BEEP DEU BEEPER TRIGGER DATE TIME LANG Press on the LEFT arro...

Страница 26: ...010 AUTOTEST 80 DO7010 MANUAL SEQU TEST SETUP TRIGGER AUTO DATE 29 03 04 TIME 12 13 LANG FRA MAINS 50HZ VERSION VER 1 0 PASSCODE CAL department on 44 0 191 587 8739 To perform a unit calibration pleas...

Страница 27: ...erances uncertainty of DO7010 unit built in resistor equal about 19 digits then the green LED lights if not the red LED lights If red LED lights we recommend to stop operating the unit and to send it...

Страница 28: ...WN arrows move the reverse video area to select the line to modify With the RIGHT arrow or the enter key enter in the menu level to set the parameters RANGE 600m CURRENT HI ZERO OFF AVERAGE OFF LOG OF...

Страница 29: ...easurement current with the UP and DOWN arrows HI 10A for the 6 to 600m ranges and 1A for the 6000 m range LO 1A for the 6 to 600m and 0 1A for the 6000 m range Enter the selection with the Enter key...

Страница 30: ...with the Enter key RANGE OFF CURRENT ON ZERO AVERAGE LOG LIMITS ESC RANGE OFF CURRENT ON ZERO AVERAGE LOG LIMITS ESC When measuring low resistances consequently low voltages the accessories and 4 1 3...

Страница 31: ...the resistance value the current the range the time and the date Select the Log mode with the UP and DOWN arrows OFF no log mode ON log mode operating if no sequence loaded REVIEW to review the alrea...

Страница 32: ...adjustment Select the LIMITS line Press on the RIGHT arrow or on the enter key Select the Limits mode and values with the UP and DOWN arrows OFF limit function not operating ON limit function operati...

Страница 33: ...4 3 Measurements in MANUAL mode with the limit function Set the LIMITS mode see chapter 4 1 5 and trigger a measurement with the green push button on the battery pack front panel or by making contact...

Страница 34: ...key Select the LOG line Press on the Enter key Select the REVIEW line Press on the Enter key The LCD screen shows the values as follows Scroll the values with the DOWN or UP arrows Escape this menu w...

Страница 35: ...33 73 Fail 16 12 03 15 06 A6 456 201 5 30 00 1 31 23 Fail 16 12 03 15 08 A6 456 201 6 30 00 1 28 73 Pass 16 12 03 15 10 A6 456 201 7 100 0 10 120 5 Fail 16 12 03 15 12 A6 456 201 8 100 0 10 115 1 Fail...

Страница 36: ...ries Each measurement protocol describes a series of measurements to be performed with the physical location or part number and test parameters current resistance threshold for every test points Selec...

Страница 37: ...er a measurement with the green push button on the battery pack front panel or by making contact on the specimen under test with the probes IMPORTANT in AUTO trigger mode it is mandatory to have first...

Страница 38: ...n key to set in flashing mode the point number enter area Enter the point number with the UP or DOWN arrows to scroll the numbers and with the RIGHT or LEFT arrows to select the position Enter the val...

Страница 39: ...next test step To cancel the FAIL confirmation press on the NO function key and trigger a new measurement 5 3 4 Example for an ABSENT point If a point to be measured is absent or non available for th...

Страница 40: ...g on the YES function key Then the unit jumps to the next test step To cancel the OVER confirmation press on the NO function key and trigger a new measurement 5 4 Sequence end After the last sequence...

Страница 41: ...ibration If you continues please contact our service department Check that the battery block is correctly fitted into the DO7010 unit encounter any problems please follow the brief check list below If...

Страница 42: ...el 44 0 191 587 8718 For Service and Calibration Contact Service Department Seaward Group Unit 11 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2LS England Tel 44 0 191 587 8739 Fax...

Страница 43: ...ISTANCE STANDARDS DIGITAL THERMOMETERS THERMOCOUPLE SIMULATORS INSULATION TEST SETS PT100 SIMULATORS UNIVERSAL CALIBRATORS HIPOT TESTERS ELECTRICAL SAFETY TESTERS Phone fax or e mail for further infor...

Страница 44: ...610021 Rev 3...

Отзывы: