9
should be installed at least 2.5 me-
ters from the floor.
- Fixed controls must be installed in
a conspicuous place.
- The card must be permanently con-
nected to the mains and not have any
type of sectioning of the power line
device 230 Vac, installer is responsi-
ble for installing a sectioning device.
And ‘necessary to install a double pole
switch with overheating category III. It
must be positioned so as to be pro-
tected against accidental closures.
- For connections, it is recommended
to use flexible cables under insulating
sheath in harmonized polychloroprene
(H05RN-F) with minimum section of
the conductors equal to 0.75 mm
2
.
- In the back of the box there are the
preparations for the possible fixing
of the product to the wall by screws
not supplied with the product.