Repair
VI. Door latches
The door latch is mounted on top of the tank and doesn’t contain a microswitch.
It uses a Hall-effect sensor in the door to sense when the door is open or
closed.
To remove door latch Hall effect sensor
1.
Remove fascia panel
-- section VA.
2. Disconnect wire harness from sensor.
3. Remove two T-10 Torx screws and remove sensor from inner door.
To remove door latch
1. Remove frame stiffener from top of tank.
702_58300000150187_ara_en_a
2. Remove one T-20 Torx screw, rotate left side of latch up from tank tabs
and remove latch from tank.