Repair
When reassembling fascia panels to doors, make sure fascia panel tabs insert
outer door slots.
Pulling out control
Prying control tabs
VD.
Heat pumps
Disconnect support strap and wire harnesses. Either unscrew (4) screws to
separate adapter from base or remove hose clamp to separate pump from
adapter. The seal ring can’t be field removed from the heat pump. To remove
pump, slide pump off sump at seal ring.
Replacement heat pump comes with motor, pump, seal ring and hose clamp.
Motor can’t be separated from pump and seal ring can’t be field installed.
702_58300000150187_ara_en_a
Seal ring
Adapter
m
CAUTION
– 75% of all controls returned
for analysis check out OK. Most control
issues are due to loose connections.