background image

INSTRUCTIONS FOR

DIGITAL BRAKE Disc

CALLIPER 100mm/4”

Model No:

VS0561

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.

USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

p

p

WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to 

when using tools and equipment.

7

DO NOT

use calliper if damaged.

3

Maintain calliper in good and clean condition for best and safest performance.

3

Keep the work area clean, uncluttered and ensure there is adequate lighting.

3

Keep children and unauthorised persons away from the work area.

7

DO NOT

use the calliper for any purpose other than for which it is designed.

7

DO NOT

get calliper wet or use in damp or wet locations, or areas where there is condensation. Keep calliper clean and dry 

using a dry cotton cloth only.

7

DO NOT

dip or submerge the calliper in any type of liquid.

7

DO NOT

expose calliper to bright sunlight or dust.

7

DO NOT

dis-assemble calliper. The calliper must be checked by qualified service personnel only.

7

DO NOT

apply any voltage to the calliper i.e. with an electric marker pen.

3

The calliper is a precision instrument. Treat with care, avoid using force and do not subject to knocks or shocks.

3

Take particular care not to damage or scratch the scale surface.

3

Use calliper in reasonably constant temperature conditions of approximately 20

O

C.

3

When not in use, 

turn off

and store calliper in a safe, dry, childproof location.

1.

SAFETY INSTRUCTIONS

1

“ON/OFF”

2

“mm/inch”

3

RS-232 connection

4

Battery cover

5

“ZERO”

6

Thumb wheel

7

“HOLD”

2.

INTRODUCTION & SPECIFICATION

Hardened and tempered stainless steel gauge, 11mm high figures in LCD display for ease of reading. Metric or Imperial read-out

with ‘Hold’ function. Zero setting control allows for comparative measurement. Include serial port connection for computer

interface. Supplied in carry case.

Specification

Vernier Calliper

Resolution

0.01mm (0.0005”)

Range

0-100mm (0-4”)

Accuracy

±0.02mm (±0.001”) 

Functions

Zero set, mm/inch select, Hold

Battery type

SR44 (1.5V)

Operating temp

0 - +40°

VS0561 - 1 - 120804

Fig.1.

INSTRUCTIONS FOR

DIGITAL BRAKE Disc

CALLIPER 100mm/4”

Model No:

VS0561

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.

USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

p

p

WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to 

when using tools and equipment.

7

DO NOT

use calliper if damaged.

3

Maintain calliper in good and clean condition for best and safest performance.

3

Keep the work area clean, uncluttered and ensure there is adequate lighting.

3

Keep children and unauthorised persons away from the work area.

7

DO NOT

use the calliper for any purpose other than for which it is designed.

7

DO NOT

get calliper wet or use in damp or wet locations, or areas where there is condensation. Keep calliper clean and dry 

using a dry cotton cloth only.

7

DO NOT

dip or submerge the calliper in any type of liquid.

7

DO NOT

expose calliper to bright sunlight or dust.

7

DO NOT

dis-assemble calliper. The calliper must be checked by qualified service personnel only.

7

DO NOT

apply any voltage to the calliper i.e. with an electric marker pen.

3

The calliper is a precision instrument. Treat with care, avoid using force and do not subject to knocks or shocks.

3

Take particular care not to damage or scratch the scale surface.

3

Use calliper in reasonably constant temperature conditions of approximately 20

O

C.

3

When not in use, 

turn off

and store calliper in a safe, dry, childproof location.

1.

SAFETY INSTRUCTIONS

1

“ON/OFF”

2

“mm/inch”

3

RS-232 connection

4

Battery cover

5

“ZERO”

6

Thumb wheel

7

“HOLD”

2.

INTRODUCTION & SPECIFICATION

Hardened and tempered stainless steel gauge, 11mm high figures in LCD display for ease of reading. Metric or Imperial read-out

with ‘Hold’ function. Zero setting control allows for comparative measurement. Include serial port connection for computer

interface. Supplied in carry case.

Specification

Vernier Calliper

Resolution

0.01mm (0.0005”)

Range

0-100mm (0-4”)

Accuracy

±0.02mm (±0.001”) 

Functions

Zero set, mm/inch select, Hold

Battery type

SR44 (1.5V)

Operating temp

0 - +40°

VS0561 - 1 - 120804

Fig.1.

Отзывы: