Sealey TA304 Скачать руководство пользователя страница 1

InstructIons for:

 

digital automotive analyser 15 function with ic/ir

 

MoDEL no

TA304

1. SAFETY

1.1.  PERSONAL PRECAUTIONS

 

When using this multimeter, please observe all normal safety rules concerning:

 

Protection against the dangers of electrical current.

 

Protection of the meter against misuse.

 

full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with genuine  

 

 

sealey leads with the same electronic ratings. failure to do so will invalidate the warranty.

 

DO NOT

 use leads if damaged or if the wire is bared in any way.

 

DO NOT

 use the meter if it has been damaged.

1.2.   GENERAL SAFETY INSTRUCTIONS

 

WARNING! USE EXTREME CAUTION

 when working with high voltages.

 

familiarise yourself with the application and limitations of the multimeter as well as the potential hazards.

 

IF IN ANY DOUBT CONSULT A QUALIFIED    

 ELECTRICIAN.

 

Before commencing testing, follow instructions below and select the correct input sockets, function and range on the multimeter.

 

When the meter is connected to a circuit, do not touch any unused meter terminals.

 

When the magnitude of the value to be measured is unknown beforehand, set the range selector to the highest value available.

 

Before rotating the range selector to change functions, disconnect test probes from the circuit under test.

 WARNING! 

Never perform resistance, transistor, diode or continuity measurements on live circuits.

 

Always take care when working with voltages above 35V Dc or 25V Ac rms. these voltages are considered a shock hazard. 

 

Always keep fingers behind the probe barriers whilst measuring and 

DO NOT

 use when hands are wet.

 

DO NOT

 touch the test leads, tips or the circuit being tested.

 

choose the proper range and function for the required measurement. 

DO NOT

 try voltage or current measurements that may exceed the ratings marked on  

 

the function/range switch. 

 

When testing for the presence of a voltage or current, make sure the meter is functioning correctly. take a reading of a known voltage or current before    

 

accepting a zero reading. 

 

DO NOT

 test voltages above 600V Ac or Dc - the circuitry of the multimeter will be destroyed.

 

 

WARNING! NEVER

 connect the multimeter to a voltage source / live circuit when the rotary switch is set to any other function apart from Voltage testing.

 

WARNING! 

Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical 

 

contacts. other means should be used to ensure that the terminals are not “live”.

 

Avoid damaging the meter when testing voltage. Disconnect the test leads from the test points before changing functions.

 

DO NOT

 attempt a voltage measurement with the test leads in the 20A or the mA terminal.

 

ALWAYS

 discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests.

 

DO NOT

 use the multimeter in a potentially explosive atmosphere or where flammable material is present.

 

ONLY

 operate the multimeter when the back cover is in place and fastened securely.

 

If any abnormal readings are observed, the multimeter must be checked out by an authorised technician.

 

ALWAYS

 turn off the multimeter and disconnect the test leads, before opening the back cover to replace the fuse or battery.

 

When not in use, store the multimeter carefully in a safe, dry, childproof location out of direct sunlight. If storing for a long period of time, remove the 

 

battery. storage temperature range: -15°c to 50°c. 

Note:

 

the warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and situations that may occur. It must be 

 

understood that common sense and caution are factors which cannot be built into this product, but must be applied by the operator.

 

WARNING! 

Engines produce carbon monoxide which is odourless and causes slower reaction time which could lead to serious injury. An engine which is   

 

operating should be in a well ventilated area, or the vehicle's exhaust should be connected to an adequate fume removal system. 

 

When working on a vehicle which is being tested or repaired ensure that the handbrake is on and the front wheels are chocked to avoid the vehicle moving  

 

and causing injury.

 

Wear suitable eye protection when testing or repairing a vehicle.

 

When measuring current, connect the meter in series with the load.

 

Disconnect the live test lead before disconnecting the common test lead.

 

the mA and the 20A terminals are protected by fuses. to avoid possible injury or damage, use only in circuits limited to 400mA or 20A for 30 seconds.

 

to maintain the accuracy of the meter, replace the discharged battery immediately when the symbol '

BAT

' appears on the meter display.

 

Avoid measurement errors from outside interference. Keep the meter away from spark plug and coil wires.

 

Exceeding the electrical limits of this meter is dangerous and will expose you to serious or possibly fatal injury. Carefully read and understand   

 

the specification limits of this meter together with the warnings and cautions in this safety section. 

 

DO NOT EXCEED ThE LIMITS ShOWN IN ThE TABLE BELOW.

 

FUNCTION

TERMINAL

INPUT LIMIT

Dc/Ac Volts, 

 

ohm/continuity/Diode, 

cAP., Ir-tEMP. Adaptor, type-K tEMP., 

Hz, % Duty, Ms Dwell, rPM

V-Ω-RPM

600VoltsAc Dc

Ac/Dc 

μA / mA

400mA Dc/Ac

Ac/Dc20A

20A

*20A Dc/Ac

*  20 Amp measurement for 30 seconds maximum.

 ohms can not be measured if voltage is present, ohms can be measured only in a non-powered circuit. However, the meter is protected to 600 volts. 

IMPORTANT:

 

PLEASE READ ThESE INSTRUCTIONS CAREFULLY. NOTE ThE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE ThE 

PRODUCT CORRECTLY AND WITh CARE FOR ThE PURPOSE FOR WhICh IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 

PERSONAL INJURY AND WILL INVALIDATE ThE WARRANTY. KEEP ThESE INSTRUCTIONS SAFE FOR FUTURE USE.

T

hank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly 

maintained, give you years of trouble free performance.

t

he user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that adequate barriers guard 

against inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips.  Where there is a risk of the probe tip 

short circuiting with other live conductors under test, it is recommended that the exposed tip length shall not exceed 4mm.

tA304  Issue:4(I) - 17/06/14

Original Language Version

 © Jack sealey Limited

Содержание TA304

Страница 1: ...YS turn off the multimeter and disconnect the test leads before opening the back cover to replace the fuse or battery When not in use store the multimeter carefully in a safe dry childproof location out of direct sunlight If storing for a long period of time remove the battery Storage temperature range 15 C to 50 C Note The warnings cautions and instructions referred to in this manual cannot cover...

Страница 2: ...PP3 Hi Impact Case Yes Size L x W x D 182 x 82 x 55mm Weight 360g fig 1 fig 2 2 introduction specification INTRODUCTION Includes new generation 15 function auto ranging automotive diagnostic multimeter with IR thermometer attachment Combination digital bar graph display gives accurate indication of component outputs Large easy to read high contrast display with bright white backlight Workshop toug...

Страница 3: ...e button to go to manual ranging The display icon will appear Each press of the range button will step to the next range as indicated by the units and decimal point location Press and hold the Range button for two seconds to return to autoranging fig 3 fig 4 5 1 Voltage V 5 1 1 Select the Volts V range with the rotary switch 5 1 2 The meter will automatically select the best voltage V range 5 1 3 ...

Страница 4: ...into the 20A or mA terminal select 20A if you are unsure of the current draw IMPORTANT Turn OFF all power to the circuit or disconnect the circuit from the power source 5 6 5 Connect the Red probe to the side of the circuit closest to the power source 5 6 6 Connect the Black probe to the side of the circuit to ground 5 6 7 Turn the power ON and test Note Current must always be measured with the me...

Страница 5: ... 5 11 7 Touch the Black test probe to a good ground at the fuel injector or the negative vehicle battery post 5 11 8 Touch the Red test probe to the fuel injector solenoid driver input on the jumper cable 5 11 9 Start the engine A pulse width in milliseconds should be read Note Initially the unit will read OL then readings will descend and stabilize to the actual pulse width If OL remains re check...

Страница 6: ...r approx 30 seconds of inactivity Operating environment 0ºC to 50ºC 32ºF to 122ºF at 70 relative humidity Storage temperature 20ºC to 60ºC 4ºF to 140ºF at 80 relative humidity For inside use max height 2000m Pollution degree 2 Power One 9V battery PP3 Dimensions 182 x 82 x 55mm Weight 360g RPM Tach Range Resolution Accuracy RPM4 600 4000 RPM 1 RPM 2 of rdg 4dgts 1000 12000 RPM x10 RPM 10RPM RPM 2 ...

Страница 7: ...river Gently ease the rear cover off 7 5 2 Remove the old fuse from its holder by gently pulling it out Take care not to touch any other internal parts of the analyser 7 5 3 Install the new fuse into its holder by gently pushing it in Note Always use a fuse of the correct size and value Fuse Ratings 20A 250V 6 3 x 32mm fast acting ceramic type for the 20A range 0 5A 250V 5 x 20mm fast acting ceram...