CURRENT TESTER 30A
model no:
TA126
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Suitable only for automotive circuits up to 48V DC.
Not suitable for domestic 110 - 230V applications.
9
observe standard workshop safety procedures when using the tester.
WARNING!
The Fuse blade may become hot during testing. Allow to cool before removing.
WARNING! DO NOT
exceed maximum load: 30A/48V for max 10sec.
9
ensure vehicle ignition is switched
OFF
before connecting or disconnecting TA126.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting. Keep tools and other items away from the engine, and
ensure you can see the battery and working parts of engine clearly.
9
maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back long hair.
9
Keep children and unauthorised persons away from the working area.
8
DO NOT
disassemble. TA126 must be checked by qualified service personnel only.
8
DO NOT
get the tester wet or use in damp or wet locations or areas where there is condensation.
8
DO NOT
use the tester for any purpose other than for which it is designed.
8
DO NOT
pull by the cables to free from the fuse terminals.
8
DO NOT
operate TA126 if damaged.
9
When not in use store in a safe, dry, childproof location.
WARNING!
The warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and situations that
may occur. It must be understood that common sense and caution are factors which cannot be built into this product, but must be
applied by the operator.
2. INTRODUCTION
Fast, accurate and safe current measurement at the fuse box or battery. Ideal for fault-finding on car and commercial vehicle electrical circuits.
Features large lCd display with numeric and bar-type functions. Plugs directly into the vehicle’s fuse board. Supplied with mini, standard adaptors
and fused crocodile clips. Compatible with alternative probes using the standard Ø4mm banana adaptors.
3. SpECIFICATION
model no. .....................................................................TA126
Range: ................................................................ 0-30A - 0-48V
Accuracy: .......................................................................... ± 2%
Fuse Type: ......................................................... mini, Standard
max load: ............................................ 30A/48V for max 10sec
operating Temp: ...........................0°C to 50°C (32°F to 122°F)
Storage Temp: ........................... -20°C to 60°C (-4°F to 140°F)
Relative Humidity: ...................<70% operating, <80% storage
operating Altitude: ............................7000ft (2000m) maximum
Original Language Version
© Jack Sealey limited
Refer to
instruction
manual
Wear eye
protection
1. lCd display
2. ZeRo Button
3. Hold Button
4. Power on/off Button
5. dATA link
6. Clip Connector
7. Standard Blade Connector
8. mInI Blade Connector
9. Fuse Jack
fig.1
TA126 | Issue 2 (H,F) 04/04/18