![Sealey TA113 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/sealey/ta113/ta113_instructions_1226955001.webp)
instructions for
fuse current tester
model no:
tA113
thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. sAfety
WArnInG!
the warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and situations that may
occur. it must be understood that common sense and caution are factors which cannot be built into this product, but must be applied by the
operator.
9
Wear eye protection. A full range of Personal Protective equipment is available from your sealey dealer.
9
for use on 6V, 12V and 24V systems only.
8
DO nOt
attempt to use in the presence of flammable gasses, use of the tester may cause sparks, which could cause an explosion.
8
DO nOt
use the tester with wet hands, indoor use only.
8
DO nOt
make any modification to the tester.
9
K
eep hands and fingers behind the barriers on the probes during measurements.
9
o
bserve standard workshop safety procedures when using the tester.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting. Keep tools and other items away from the engine, and ensure
you can see the fuses and working parts of engine clearly.
9
maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back long hair.
9
K
eep children and unauthorised persons away from the working area.
9
When not in use store in a safe, dry, childproof location.
2. IntrODuctIOn
t
he next level of simplicity in hand-held automotive current measuring tools. Revolutionary new methods now makes it possible to determine the
amount of current in a fused circuit, without removing the fuse. Troubleshoots parasitic drain problems and identifies active/inactive circuits via
the fuse box. Suitable for 6, 12, and 24v systems. Powered by 3 x AA batteries (supplied).
3. specIfIcAtIOn
Model no: ....................................................................tA113
m
aximum current:
............................................................50A
current range: ......................................................... 5mA-50A
m
aximum voltage:
............................................................24V
Accuracy: ........................................................................±5%
Warning:
r
isk of
explosion
Wear eye
Protection
refer to
instruction
manual
t
A113| Issue 1 09/02/16
Original Language Version