1.  SAfety

 

‰

  

WArnInG!

 ensure Health & Safety, local authority and general workshop practice requirements are adhered to when using this  

 

 equipment.

 

‰

   WArnInG!

 

this equipment can be used in a wide variety of conditions and situations including workshop, industrial  

 

  and marine environments. 

In each case, the user of the equipment must familiarise themselves with the safety regulations that    

  apply to the particular conditions or situation in which the equipment will be used and do their own risk assessment in order to stay safe  

  and avoid personal injury.

 

9

   Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip footwear.

 

9

   Keep the anemometer clean and in good condition.

 

9

   Protect the anemometer from solvents, acids or other aggressive substances.

 

9

   Keep children and unauthorised persons away from the work area.

 

8

  

Do not

 get the anemometer wet or use in damp or wet locations or areas where there is condensation.

 

8

  

Do not

 use the anemometer for any purpose other than that for which it is designed.

 

8

  

Do not

 use the anemometer if any part of it is damaged.

 

8

  

Do not

 allow untrained persons to use the anemometer.

 

8

  

Do not

 use the anemometer when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

9

   When not in use, clean the anemometer and store in a safe, dry, childproof area.

 

‰

  

WArnInG! the warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that  

  may occur. It must be understood that common sense and caution are factors which cannot be built into this product, but    

  must be applied by the operator. 

2.  IntroDuctIon

Wind speed measuring device featuring live/max/average/wind chill and Beaufort scale. Ideal for checking workshop dust/fume extraction 

devices. Also reads temperature which can be measured in either °C or °F. Readings are displayed on a 24mm high back-lit lCd screen. 

Features a battery indicator and auto/manual power off.

3.  SpecIfIcAtIon

Model no: ....................................................................TA070

Battery: ............................................... CR2032 3V (supplied)

nett Weight: ................................................................0.07Kg

4.  operAtIon

4.1.    

Switch on procedure

4.1.1. 

  

Hold down the MODE button (fig1.1) for 2 seconds.  

 

 

The unit will display the Air Velocity, Temperature and Battery  

 

Condition. The screen backlight will illuminate for 12  

 

 seconds.

4.2.    

Setting the unit of measurement (Air Velocity)

4.2.1.   

With the unit switched on, hold down the Mode button  

 

 

(fig.1.1) for 3 seconds until the ‘m/s’ symbol on the  

 

 

display screen (fig.2) starts to flash. 

4.2.2. 

  

Press the SET button (fig.1.2) to scroll down to the desired   

 

unit of measurement on the display screen (fig.2).

4.2.3.   

once the desired unit of measurement for air velocity has    

 

been selected, press the MODE button (fig.1.1) to confirm the  

 selection.

TA070 Issue 2 (HF) 17/05/18