instructions for
digital tachometer contact/non-contact
model no:
ta050
thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SaFetY
1.1.
general SaFetY
Warning!
Ensure that Health & Safety, local authority and general workshop practice regulations are adhered to when using this
equipment.
Warning!
DO NOT
aim the laser beam at your or another person’s or animal’s eye and beware of reflections from mirrors or other shiny
surfaces.
9
familiarise yourself with the applications, limitations, and potential hazards of the tachometer.
9
Keep the tachometer clean and in good condition.
9
Protect the tachometer from electro-magnetic fields, static electricity and high temperatures.
9
remain vigilant when using the tachometer on, or near, a running engine where there are rotational parts such as belts, pulleys and fans.
9
maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
remove ill fitting clothing. remove ties, watches, rings, and other loose jewellery, and contain and/or tie back long hair.
8
do not
wear gloves near rotational parts.
8
do not
get the tachometer wet or use in damp or wet locations or areas where there is condensation.
8
do not
use the tachometer
for any purpose other than for which it is designed.
8
do not
allow untrained persons (particularly children) to operate the tachometer.
8
do not
operate the tachometer
when you are tired or under the influence of alcohol, drugs or intoxicating medication.
1.2.
laSer SaFetY
the tA050 utilises a class ii laser that emits low levels of visible radiation (i.e. wavelengths between 400 and 700 nanometres)
which are safe for the skin but not inherently safe for the eyes. the class ii emission limit is set at the maximum level for
which eye protection is normally afforded by natural aversion responses to bright light. Accidental eye exposure is therefore normally
safe, although the natural aversion response can be overridden by deliberately staring into the beam, and can also be influenced by
the use of alcohol or drugs.
Warning!
do not
look or stare into the laser beam as permanent eye damage could result.
8
do not
direct the laser beam at any person’s (or animal’s) eyes as eye damage could result.
do not
operate the tachometer when you are tired or under the influence of alcohol, drugs or intoxicating medication.
9
Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye exposure.
2.
i
introduction
Professional quality laser instrument for fast and accurate measurement of rotational speed with or without contact. Will also measure total
revolutions, frequency, surface speed and distance. ten selectable data set memories each with maximum, minimum, and average or single
value reading as appropriate. supplied with reflective tape, for non-contact measurement, and three heads for contact measurement. Powered
by 9V battery (supplied) and has jack socket for 6V dc supply.
3.
i
SpeciFication
rotational speed - contact: ............................... 2 - 20,000rpm
rotational speed - non-contact: ........................ 2 - 99,999rpm
total revolutions: ..................................................... 1 - 99,999
sampling time: ............................................ 0.5s @ > 120rpm
Accuracy: ..................................................... ±(0.05% + 1 digit)
surface speed: ........................................m/m, in/m, ft/m, yd/m
distance: .................................................................m, in, ft, yd
frequency: ........................................................................... Hz
Battery: ...............................................................................PP3
external Power: ...............................................................6Vdc
laser output: .............<1mW, Wavelength 630-670nm class ll
Original Language Version
© Jack sealey limited
refer to
instruction
manual
electrical shock
Hazard
laser
Avoid eye
contact
fig.1
tA050 issue 5 (H,3,4,f) 02/03/18