background image

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

1. SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND

CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

INSTRUCTIONS FOR:

HIGH CAPACITY WORKSHOP 
CLEANING TANK

Model:

SM21/C

1.2

GENERAL SAFETY

p

WARNING!

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

3

Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to the cleaning tank.

p

WARNING!

Disconnect the parts washer from the mains power before changing accessories, servicing or performing any maintenance.

3

Maintain the parts washer in good condition (use an authorised service agent).

3

Replace or repair damaged parts. 

Use genuine parts only. Non-authorised parts may be dangerous and will invalidate the warranty.

p

WARNING!

DO NOT modify the lid or jam it open. Keep the lid and holding screws in place, tight and in good working order.

3

Locate the parts washer in an adequate working area for its function, Ensure the washer is stood on a firm level surface. Keep area clean

and tidy and free from unrelated materials. Ensure the area is well ventilated and has adequate lighting.

3

Keep the cleaning tank away from heat sources such as heater, sparks, open flames etc.

3

Keep the tank clean. Remove and clean the filter regularly for best and safest performance.

3

Ensure there are no flammable or combustible materials near the work area.

p

WARNING! 

Always wear approved eye or face protection when operating the cleaning tank. 

3

Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.

3

Wear appropriate protective clothing.

3

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

3

Keep children and unauthorised persons away from the working area.

3

Avoid accidental starting of the washer. Ensure unplugged from mains when not in use.

3

Incase of fire in parts unit, close the lid, do not attempt to remove parts, or the washer. 

7

DO NOT use the cleaning tank for any purpose other than for which it is designed.

7

DO NOT use cleaning tank in wet or damp locations or areas where there is condensation. 

7

DO NOT use the cleaning tank where there are flammable liquids, solids or gases.

7

DO NOT allow untrained persons to operate the cleaning tank.

7

DO NOT over fill the cleaning tank with solvent. Full capacity should be just below the parts tray.

SM21/C - 0016 - (2) - 090300

1.1.

ELECTRICAL SAFETY. 

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are

plugged into an electrical supply not protected by an RCCB. 

If in doubt consult a professional electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

also read

and understand the following instructions concerning electrical safety.
1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by a 

qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of the appliance

and the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power 

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply, leads, plugs for wear and damage and all electrical connections  

to ensure that none are loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used, and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require 

a fuse smaller than 13 amps for certain products (

subject to 1.1.10. below)

see fuse rating at right. 

1.1.7. DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8. DO NOT pull power plugs from sockets by the power cable.

1.1.9. DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by 

a qualified Electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off 

and fit a new plug according to the following instructions (discard old plug safely).

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to live terminal ‘L’.

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation

extends beyond the cable restraint and that the restraint is tight.

Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked with

this symbol      . 

To re-wire, connect the brown & blue wires as indicated above. DO NOT 

connect the brown or blue to the earth terminal.

1.1.10. Some products require more than a 13 amp electrical supply. In such a case, 

NO

plug will be fitted. 

You must

contact a qualified electrician to 

ensure a 30 amp fused  supply is available. We recommend you discuss the installation of a industrial round pin plug and socket with your electrician. 

1.1.11.

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores of the cable

on the reel is important. Use1.5mm

2

section cable as a minimum, but to be absolutely sure that the capacity of the cable reel is

suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm

2

section cable.

Blue

Neutra

l

 

Yellow & Green 

Earth wire 

Cable

restrai

FUSE RATING

THIS PRODUCT MUST BE FITTED 

WITH A

3 AMP FUSE

Brown

Live 

wire

Отзывы: