INSTRUCTIONS FOR:

AIR HYDRAULIC PUMP 10TONNE

MODEL Nos: 

RE83/840.v2 & RE83/840/CWH.v2

 

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE 

DAMAGE AND/OR PERSONAL INJURY AND WILL INvALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

 

WARNING!

 

Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using this equipment.

  Familiarise yourself with product application and limitations, as well as the specific hazards peculiar to the pump.

 

WARNING!

 

Disconnect the hydraulic pump from the apparatus before servicing or performing any maintenance.

  Maintain pump in good order. Replace/repair with

 genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

  Use qualified person to lubricate and maintain the hydraulic pump. 

DO NOT

 use brake fluid to top up hydraulic unit. Use Sealey hydraulic oil only.

  Keep the pump and treadle clean for best and safest performance.

 

WARNING! Ensure you know how much load you are pushing. Never exceed the maximum pushing capacity. 

  The kit accessories may be used with other popular makes of kit.

 

We recommend the use of BS approved safety impact goggles and heavy duty gloves when working with this pump. Both are available from your  

  authorised Sealey dealer.

  Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

  If working on an ‘off centre’ load, pump with care. If you feel undue resistance, stop and re-adjust the set-up.

  Ensure any hydraulic hoses are not bent or kinked but laid out correctly. Avoid damage to hoses (e.g. crushing/cutting). 

  Keep non-essential persons away from the operating area. Be aware of the locations of other persons assisting you.

 

DO NOT

 operate the pump if any parts are damaged or missing as this may cause failure and/or personal injury. 

 

WARNING! DO NOT use for any purpose other than for which it is designed.

  When not in use, place dust cap in end of hydraulic hose or cylinder and store in a safe, dry, childproof location.

Only fully trained and qualified persons should use this equipment. These instructions are not a substitute for user receiving full  

 supervised training by a qualified person. It is important the user understands the  applications, limitations and potential hazards     

 of the product.

Original Language Version

RE83/840.V2 & RE83/840/CWH.V2    Issue: 1 - 13/11/12 

MODEL: RE83/840.V2

MODEL: RE83/840/CWH.V2

© Jack Sealey Limited

2. INTRODUCTION/SPECIFICATIONS

2.1

 

Suitable for use with SuperSnap

 

  hydraulic ram as supplied with Model No. DZRE92/C body straightener and all body kits. 

                               

 

Air Supply 

Oil Pressure 

Oil Capacity 

Hose 

 Model No. RE83/840.V2 

 

90-120psi  

10000psi   

450cc 

 

not supplied

 Model No. RE83/840/CWH.V2 

90-120psi  

10000psi   

450cc 

 

supplied (loose)

R