background image

 

Familiarise yourself with the application and limitations of the compressor.

 

Ensure that the compressor is in good order and condition before use. If in any doubt do not use the unit and contact a service agent.

 

  WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust the pressure    

 

switch or the safety valve.

 

Before moving or maintaining the compressor

 

ensure that the air tank pressure has been vented. 

 

Only use recommended attachments and parts. Using unapproved items may be dangerous and will invalidate the warranty.

 

Read the instructions for any accessory used with the compressor. Ensure that the safe working pressure of any air appliance used,  

 

 

exceeds the output pressure of the compressor. If using a spray gun, check that the area selected for spraying is provided with an air  

 

 

change system or adequate ventilation. 

 

Ensure that the air supply valve is turned off before disconnecting the air supply hose.

 

To move the compressor use the front roll bar. Lift the compressor so that the front legs have enough clearance for manoeuvring but  

 

 

maintain the centre of gravity in front of the wheels. 

DO NOT

 attempt to lift or move the compressor by any other means.

 

Use the compressor in a well ventilated area and ensure it is placed on a firm surface. 

Remember that the compressor engine  

 

 

produces harmful exhaust fumes.

 

Keep tools and other items away from the compressor when it is in use, and keep work area clean.

 

Ensure that air hoses are not tangled, twisted or pinched.

 

Keep children and unauthorised persons away from the work area.

 

DO NOT

 dis-assemble the compressor for any reason if you are not qualified to do so. The unit must be checked by qualified personnel only.

 

DO NOT

 operate the compressor within the vicinity of flammable liquids, gases or solids.

 

DO NOT

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after   

 shutdown.

 

DO NOT 

operate the compressor without all safety guards in place.

 

DO NOT 

attempt to move the compressor by pulling the air tool hose.

 

DO NOT

 use the compressor for a task for which it is not designed.

 

DO NOT

 deface the certification plate attached to the compressor tank. 

  

DANGER! DO NOT direct the output jet of air towards people or animals.

 

DO NOT

 operate the compressor without an air filter.

 

DO NOT

 allow anyone to operate the compressor unless they have received full instructions.

  For safety instructions relative to the maintenance and use of the petrol engine - refer to the engine manufacturer’s handbook supplied.

  DO NOT

 check the ignition system by removing the spark plug or spark plug lead. Use specific tester or contact service agent.

 

WARNING! DO NOT touch the spark plug or plug lead whilst the engine is running - severe, potentially fatal, electric shock may  

 result. 

  Ensure that engine fuel is stored in an approved container. For long term storage ensure that the fuel tank is drained and that the  

 

 

compressor is adequately protected.

  DO NOT

 smoke or have any naked flames nearby whilst re-fuelling.

  DO NOT

 leave the compressor operating unattended.

 

DO NOT

 remove the fuel cap, or try to refuel whilst the engine is running. Stop the engine and allow it to cool for two minutes before  

 

 

attempting to refuel.

  DO NOT

 refuel in a closed or poorly ventilated environment as there is a danger of explosion or fire. Refuel outdoors.

  DO NOT

 operate the compressor if there is a fuel leak. Move the unit to a safe area, where 

 

there is no risk of ignition, until the leak has been rectified and the machine is dry.

  DO NOT

 start the engine if there are any flammable materials near the exhaust

 

system or in the path of the exhaust gases.

  DO NOT

 block the engine ventilation grilles.

 

DO NOT

 cover the compressor or restrict air flow around the machine whilst

 

it is operating.

  

WARNING! The air tank is a pressure vessel and the following safety 

 

measures apply:

  DO NOT 

tamper with the safety valve and 

DO NOT 

modify or alter the tank 

 

in any way and 

DO NOT

 strap anything to the tank.

  DO NOT subject the tank to impacts, vibration or to heat and DO NOT 

 

allow contact with abrasive or corrosive materials.

  DO drain condensation from tank daily and inspect inside walls for 

 

corrosion every 12 months. 

  The tank shell must not fall below the certified thickness at any point. 

 

When not in use, store the compressor carefully in a safe, dry, childproof location.

InSTRUcTIOnS FOR:

cOMPRESSOR 50LTR BELT DRIVE

PETROL EnGInE 5.5HP

MODEL no: 

SA5055

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND 

CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY 

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

Original Language Version

SA5055    Issue: 2 (SP) - 23/08/13

 © Jack Sealey Limited 2013

Содержание Power PRODUCTS SA5055

Страница 1: ...structions relative to the maintenance and use of the petrol engine refer to the engine manufacturer s handbook supplied DO NOT check the ignition system by removing the spark plug or spark plug lead Use specific tester or contact service agent WARNING DO NOT touch the spark plug or plug lead whilst the engine is running severe potentially fatal electric shock may result Ensure that engine fuel is...

Страница 2: ...ess than the maximum pressure the relief valve will automatically close and the tank pressure will increase back to it s maximum Note a If the relief valve does not cut in and out but is continuously closed whilst using an air appliance the capacity of the compressor may be too small for the equipment or tool b The larger gauge fig 3 2 indicates the pressure inside the tank NOT the pressure suppli...

Страница 3: ...s in a very dusty atmosphere Remove the air filter element by undoing the bolt and removing the filter cover fig 7 Clean the filter by blowing through from the clean side with an air line at low pressure Replace filter cover and bolt Do not operate compressor without filter as foreign bodies or dust could damage the pump WARNING Wear safety goggles when performing this task b Clean compressor c Ch...

Страница 4: ... for leaks or Contact Authorised Service Agent Empty air tank remove the relief non return valve fig 2 fig 9 and clean the seat D If necessary replace the seal E 6 TROUBLESHOOTING Compressor makes metallic rattle Bearing or piston fault Contact Authorised Service Agent Safety valve operates below max pressure Faulty valve 5 3 Scheduled maintenance table not engine NOTE It is our policy to continua...

Отзывы: