background image

INSTRUCTIONS FOR: 

WOBBLE LIGHTS

MODELS: 

ML20 & ML40

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL

REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY
AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component

parts without prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this equipment. 

WARRANTY: 

Guarantee is 12

months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our latest catalogue and 

promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

E-mail: [email protected]
Web: www.sealey.co.uk

01284 703534

Sole UK Distributor, Sealey Group

, Bury St. Edmunds, Suffolk.

1.1

ELECTRICAL SAFETY

!

WARNING!

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, 
sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by 
the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main
distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an 
RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a 
qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 
You must also read and understand the following instructions concerning electrical safety.

1.1.1 The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2 The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those 

appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and

1.1.2 and use a Portable Appliance Tester.

1.1.4 Ensure that cables are always protected against short circuit and overload.
1.1.5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is 

loose.

1.1.6 Important: Ensure that the voltage marked on the appliance matches the power 

supply to be used and that the plug is fitted with the correct fuse - see fuse rating 
at right.

1.1.7

DO NOT 

pull or carry the appliance by the power cable.

1.1.8

DO NOT

pull the plug from the socket by the cable.

1.1.9

DO NOT

use worn or damaged cables, plugs or connectors. Immediately have 

any faulty item repaired or replaced by a qualified electrician. When a BS 1363/A
UK 3 pin plug is damaged, cut the cable just above the plug and dispose of the 
plug safely. 
Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer 

insulation extends beyond the cable restraint and that the restraint is tight. Double insulated products, which are always 
marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only. To rewire, connect the wires as 
indicated above - 

DO NOT

connect either wire to the earth terminal.

1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician 

to ensure that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin
plug and socket with your electrician.

1.1.11 If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any 

appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be 
absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output
sockets, we recommend the use of 2.5mm² section cable.

1.2

GENERAL SAFETY

!

WARNING! Disconnect lamp from mains power before changing tube or performing any maintenance.

"

Replace or repair damaged parts. 

Use genuine Sealey parts only. Unauthorised parts may be dangerous and will invalidate 

the warranty.

"

Maintain the lamp in good condition.

#

DO NOT

use the lamp if damaged.

#

DO NOT

use lamp close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning rags. 

#

DO NOT

fit a fluorescent tube other than the recommended replacement (see parts list for part numbers).

"

When not in use switch off the lamp and remove plug from power supply.

FUSE RATING 3 AMP

Blue
Neutral 
Wire

Yellow & Green 
Earth Wire 

Cable 
Restraint

Brown
Live 
Wire

ML20-ML40 - 1 - 060605

PARTS LIST FOR: 

WOBBLE LIGHTS

MODELS: 

ML20 & ML40

1.

SAFETY INSTRUCTIONS

- ML20
ITEM

PART NO.

DESCRIPTION

01.

MLT18

FLUORESCENT TUBE

02.

MLT18.C

PLASTIC TUBE

03.

ML20.BASE

BASE HOUSING FOR ML20/ML40

04

ML20.ASSY

BASE ASSEMBLY UNIT FOR ML20/40

-

ML20B

BATTERY

-

ML20C

CHARGER

- ML40
ITEM

PART NO.

DESCRIPTION

01.

MLT36

FLUORESCENT TUBE

02.

MLT36.C

PLASTIC TUBE

03.

ML20.BASE

BASE HOUSING FOR ML20/ML40

04

ML20.ASSY

BASE ASSEMBLY UNIT FOR ML20/40

-

ML20B

BATTERY

-

ML20C

CHARGER

Issue:  . . . . . . . . . . .2
Issue Date:  .18/08/06

Отзывы: