background image

instructions for:

LED fLooDLight with brackEt 

anD pir sEnsor 10w 230V

MoDEL no: 

LED110s 

thank you for purchasing a sealey product. Manufactured to a 

high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT

:  

pLEasE rEaD thEsE instrUctions carEfULLY. notE thE safE opErationaL rEQUirEMEnts, warnings, anD 

caUtions. UsE this proDUct corrEctLY, anD with carE for thE pUrposE for which it is intEnDED. faiLUrE to Do so 

MaY caUsE DaMagE, or pErsonaL inJUrY, anD wiLL inVaLiDatE thE warrantY.

  1.   safEtY instrUctions

  4.  instaLLation instrUctions

  2.  introDUction

  3.  spEcification

fig 1.

Original Language Version

LED110s    issue: 1 - 16/07/12

specifications:

supply......................................................................................................230Volt.

Power: ..................................................................................................... 10Watt.

Lumen output .............................................................................................600lm

Detection Angle: ..................................................................... 120° (fan shape).

Detection range: ..................................................................... 12m (Adjustable).

time Delay: .............................................6 seconds to 20 minutes (Adjustable).

Light sensitivity: .................................................................. 30 Lux (Adjustable).

1.1.  ELEctricaL. 

 

WArninG! it is the user’s responsibility to read, understand and  

 

comply with the following:

 

WArninG! tHis ProDuct Must BE instALLED BY A QuALifiED  

 

ELEctriciAn.

 

You must check all electrical equipment and appliances to ensure they  

 

are safe before using. You must inspect power supply leads, plugs and  

 

all electrical connections for wear and damage. You must ensure the risk  

 

of electric shock is minimised by the installation of appropriate safety  

 

devices. An rccB (residual current circuit Breaker) should be  

 

incorporated in the main distribution board.  

You must

 also read and  

 

understand the following instructions concerning electrical safety. 

1.1.1.  Ensure the light is connected to an appropriate electrical on/off switch. 

1.1.2.  Ensure the insulation on all cables and the product itself is safe before  

 

connecting to the mains power supply. 

1.1.3.  Ensure that cables are always protected against short circuit and  

 

overload.

1.1.4.  regularly inspect power supply, leads, plugs and all electrical  

 

connections for wear and damage, especially power connections, to  

 

ensure that none are loose. 

1.1.5. 

Important: 

Ensure the voltage marked on the product is the same as  

 

the electrical power supply to be used.

1.1.6. 

Do not

 pull power cable once installed.

1.1.7. 

Do not

 pull power plugs from sockets by the power cable.

1.1.8. 

Do not

 use worn or damaged leads, plugs or connections.    

 

immediately replace or have repaired by a qualified Electrician. 

1.1.9

  Ensure the unit is correctly earthed and wired according  

 

to fig.1 to the right.

 

Slide the gland nut and silicon cable seal over the cable  

 

before inserting it through the cable entry gland in the  

 

base of the rear cover. 

 

a)   Connect the gREEN/YEllOw earth wire to the earth  

 

 

terminal ‘E’.

 

b)  Connect the bROwN live wire to live terminal ‘l’.

 

c)   Connect the bluE neutral wire to the neutral terminal ‘N’.

 

After wiring, check there are no bare wires, that all wires  

 

have been correctly connected and that the cable entry  

 

gland nut is tight.

 

1.2.  gEnEraL safEtY. 

 

warning! turn off the mains power supply before servicing or  

 

performing any maintenance.

 

Maintain the light in good condition (repairs must only be undertaken  

 

by a qualified electrician).

 

replace or repair damaged parts. use genuine parts only, non  

 

authorised parts may be dangerous and will invalidate the warranty.

 

Ensure the light is installed correctly in accordance with these  

 

instructions. 

 

only install the light on a vertical surface. Do not fix the light on any  

 

horizontal surface  i.e. ceiling, or overhang.

 

ideally the installation should be away from flammable or combustible  

 

materials such as wood, cloth, paper etc.

    DangEr! Do not direct the light into a persons eyes. this unit  

 

has a very intensive light output, which if incorrectly used could  

 

cause eye damage.

 

Do not

 install the light where it is likely to be knocked or hit.

 

Do not

 install in bathrooms, shower rooms, sauna or such locations.

 

Do not

 install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc.

 

Do not

 touch the light when operating, allow to cool before touching,  

 

light operates at high temperature.

 

Do not

 use the light without the front glass shield. Avoid touching the  

 

glass shield as handling may reduce its serviceable life and cause the  

 

glass to crack.

 

Do not

 use the light near flammable, combustible or explosive   

 

liquids, solids, gases or equipment.

whilst still keeping costs lower than traditional halogen bulbs. Even spread of 

light across a 120° angle. fitted with adjustable sensitivity and light duration 

controls. supplied without mains cable and suitable for outdoor mounting.

Motion detector unit automatically switches on when approached by vehicles or 

people. Mounted in die-cast powder coated aluminium housing with wall 

bracket. state of the art LED chip technology allows ultra bright illumination

 

warning! Do not

 connect unit to the mains power supply  before  

 

installation. When ready, the lamp must only be connected to the mains  

 

by a qualified electrician.

4.1.   fitting

 

Give careful consideration to the position of unit to ensure you obtain  

 

maximum benefit from the lighting range, and that an appropriate  

 

electrical power source can be provided. 

4.1.1 

Do not

 install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc  

 

as variance in temperature will effect the sensitivity of light. the light  

 

must be mounted on a vertical surface only i.e. on a wall etc. 

 

Do not

 mount on a horizontal surface i.e. ceiling or an overhang, 

 

Do not

 mount so that the face of the lamp is pointing upwards, or is  

 

facing towards the mounting surface. An approximate appropriate  

 

mounting height from the ground is 2.5m. 

4.1.2  this LED floodlight develops minimal heat and is not subject to the  

 

same mounting restrictions that apply to halogen lamps that become too  

 

hot to touch. We do however recommend that the floodlight should not  

 

be placed in cramped or restrictive positions and should be fixed at the  

© Jack sealey Limited