background image

MEDIUM STROKE HAMMER KIT

MODEL NO: 

GSA12

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

 

‰

  

WARNING!

 

Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using this equipment.

 

‰

  

WARNING!

 Disconnect the hammer from the air supply before changing accessories, servicing or performing any maintenance.

 

9

   Keep the hammer clean and maintain it in good condition.

 

9

   Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty

 (use an  

  authorised service agent).

 

9

   Keep the work area clean and uncluttered. Ensure that there is adequate lighting.

 

9

   Ensure chisels are correctly rated for the job. 

DO NOT

 use damaged or suspect chisels.

 

‰

  

WARNING! 

Wear approved safety eye or face protection, ear defenders and, if dust is generated, respiratory protection.

 

9

   Keep hands and body clear of the work when operating the hammer.

 

9

   Maintain correct balance and footing. Ensure that the floor is not slippery and wear non-slip shoes.

 

9

   Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain and/or tie back long hair.

 

9

   Keep children and unauthorised persons away from the work area.

 

9

   Secure unstable workpiece with a clamp, vice or other adequate holding device. 

 

9

   Avoid unintentional starting.

 

‰

  

WARNING!

 Ensure that the correct air pressure is maintained and not exceeded. 

 

9

   Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections are secure.

 

8

  

DO NOT

 use the hammer for a task it is not designed to perform.

 

8

  

DO NOT

 operate the hammer if any parts are damaged or missing as this may cause failure and/or personal injury.

 

‰

  

WARNING!

 

DO NOT

 chisel into any materials containing asbestos.

 

8

  

DO NOT

 switch the hammer on whilst the chisel is in contact with the workpiece.

 

8

  

DO NOT

 carry by the hose, or yank the hose from the air supply.

 

8

  

DO NOT

 hold the workpiece by hand. Use clamps or a vice (not included) to secure the workpiece. Available from your Sealey stockist. 

 

8

  

DO NOT

 allow untrained persons to operate the hammer.

 

8

  

DO NOT

 operate the hammer when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 use hammer where there is flammable liquid, solid or gas such as paint solvent, including waste wiping or cleaning rags etc.

 

8

  

DO NOT

 leave the hammer operating unattended.

 

8

  

DO NOT

 carry the hammer with your finger on the trigger. 

 

8

  

DO NOT

 direct air from the air hose at yourself or others.

 

9

   When work is complete ensure that the air supply is turned off.

 

9

   When not in use disconnect from the air supply and store in a safe, dry, childproof area.

2. 

INTRODUCTION

 

Generation Series air hammer kit. Handle exhaust reduces noise emission, and contoured soft grip allows added comfort and control.  

 

Chisel variety covers a range of different job applications. Supplied in storage case.

3.  SPECIFICATION

Model no .....................................................................GSA12

Chisel shank size .......................................401” Parker Taper

Free speed .............................................................. 4300bpm

Stroke .......................................................................... 43mm

Inlet size ....................................................................1/4”BSP

Operating pressure ....................................................... 90psi

Noise power/pressure ........................................ 106/95dB(A)

Vibration/uncertainty ......................................... 12.17/1.03m²

4.  AIR SUPPLY

4.1. 

  

Recommended hook-up procedure is shown in fig 1.

4.2. 

  

Ensure tool air valve (or trigger) is in “off” position before connecting to the air supply.

4.3. 

  

You will require an air pressure of 90psi, and an air flow according to specification.

 

‰

  

WARNING!

 Ensure the air supply is clean and does not exceed 90psi while operating the tool. Too high an air pressure and unclean air  

  will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.

Original Language Version

© Jack Sealey Limited

      Refer to

   instructions

 Wear eye

protection

 Wear protective

gloves

 Wear ear

protection

 Wear a mask

Содержание GSA12

Страница 1: ...NOT use the hammer for a task it is not designed to perform 8 DO NOT operate the hammer if any parts are damaged or missing as this may cause failure and or personal injury WARNING DO NOT chisel into any materials containing asbestos 8 DO NOT switch the hammer on whilst the chisel is in contact with the workpiece 8 DO NOT carry by the hose or yank the hose from the air supply 8 DO NOT hold the wor...

Страница 2: ...TO 1000 If there is no oiler in the air system then a teaspoon of oil can be poured into the air inlet of the hammer or into the hose at the nearest connection to the air supply Then run the hammer for a short time Note The following external factors may cause loss of power and effect hammer performance 6 2 The air supply reduced compressor output excessive drain on the air line moisture or restri...

Страница 3: ... the above Directive s Technical file compiled by Jack Sealey Ltd Being the responsible person appointed by the manufacturer Signed Date Name Position Place Bury St Edmunds Air Hammer Kit Medium Stroke GSA12 v1 2006 42 EC Machinery Directive References to harmonised standard s EN ISO 11148 4 2012 EN ISO 15744 2008 EN ISO 28927 10 2011 5 December 2019 Steve Buckle Marketing Director XVII2813 Sealey...

Страница 4: ...uired for any claim Parts Information Air Hammer Kit Medium Stroke Model No GSA12 Item Part No Description 1 GSA11 01 HOUSING 2 GSA01 05 SPRING PIN M2 6 X 22 3 GSA01 08 VALVE SEAT 4 GSA01 09 THROTTLE VALVE 5 GSA11 05 VALVE SPRING 6 GSA11 06 EXHAUST DEFLECTOR 7 GSA01 12 AIR INLET 8 GSA11 08 PLASTIC GRIP 9 GSA11 01 HOUSING 10 GSA11 10 TRIGGER SHAFT 11 GSA01 06 TRIGGER Item Part No Description 12 13 ...

Отзывы: