  1.  SAFETY INSTRUCTIONS

INSTRUCTIONS:

PETROL WATER PUMP 50mm 5.5hp

 

MODEL 

No

:

 

EWP050

1.1  GENERAL SAFETY

 

WARNING!

 Stop the engine and disconnect the inlet and outlet  

 

pipes before performing any maintenance.

 

WARNING!

 Do not operate the pump if damaged. Replace or  

 

repair using recommended parts only. Unauthorised parts may

 

be dangerous and will invalidate your warranty. Use authorised  

 

Service agent only.

  Keep the pump in good condition. Regular maintenance will  

 

give the best and safest performance.

 

WARNING! DO NOT

 operate the pump without any water  

 

passing through it. To do so will damage the machine.

 

WARNING! DO NOT

 operate the pump without the priming it  

 

first. To do so will damage the machine.

 

WARNING!

 Use the pump on a flat, level surface, in a   

 

horizontal position. Failure to do so will invalidate your warranty.

  Wear safety goggles, adequate protective clothing and  

 

anti-slip rubber soled footwear.

  Keep all persons and animals at a safe distance from the  

 

working pump

 

DO NOT

 allow children or untrained persons to operate the pump.

 

DO NOT

 use the pump if the water inlet pipe is damaged.  

 

Also check that the hose is laid out straight and safely.

 

DO NOT

 try to move the pump by pulling on the inlet or outlet  

 

pipes. Use the machine frame.

 

DO NOT

 direct the pump output towards yourself, other  

 

persons or animals, electrical equipment or the pump itself.

 

DO NOT

 use the pump if you are tired or under the influence of  

 

alcohol, drugs or intoxicating medication.

  When not in use, drain any water from the pump. Clean and  

 

dry the pump and store in a safe, dry, childproof area. 

 

DO NOT

 allow the pump to become frozen.

1.2

 

ENGINE SAFETY

 

WARNING! Check the engine oil level before each startup.  

 

Only use an SAE10W30 oil and never operate the engine  

 

with insuffient oil. 

 

WARNING! DO NOT

 touch spark plug or plug lead with wet (or  

 

dry) hands whilst the engine is running - severe, potentially  

 

fatal, electric shock may result. 

  For safety instructions relative to the maintenance and use of  

 

the petrol engine refer to the engine instruction manual.

 

DO NOT

 check ignition system by removing the spark plug or  

 

spark plug lead. Use specific tester or contact service agent.

 

DO NOT

 operate the pump in an enclosed area as the motor  

 

exhaust fumes are a health hazard.

 

DO NOT

 use the pump with flammable, toxic or corrosive liquids.

 

DO NOT

 leave the pump unattended whilst operating, and 

DO

  

 

NOT

 remove the fuel cap whilst the engine is running.

 

DO NOT

 refuel the engine whilst it is running. Stop the engine  

 

and allow it to cool for two minutes before attempting to refuel.

 

DO NOT

 refuel in a closed or poorly ventilated environment as  

 

there is a danger of explosion or fire. Refuel out doors.

 

DO NOT

 smoke or place the pump near any naked flames  

 

whilst re-fuelling.

 

DO NOT

 operate pump if there is a fuel leak. Move the unit and  

 

avoid any combustion until the leak has been fixed and the  

 

machine is dry.

 

DO NOT

 start the engine if there are any flammable materials  

 

near the exhaust system or in the path of the exhaust gases.

  2.  INTRODUCTION & SPECIFICATION   

  3.  FITTINGS & ACCESSORIES   

Model No:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EWP050

 

Motor Power:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5hp 

Motor Type:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-stroke/Unleaded 

Inlet Ø:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mm 

Outlet Ø:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mm 

Maximum Output:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600ltr/min 

Maximum Head:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26mtr 

Maximum Suction Head:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8mtr 

Maximum Tank Capacity:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.6ltr 

Noise Rating LwA: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99dB

Dry Weight:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27kg 

Dimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .477 x 385 x 417

Lay Flat Hose:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LFH1050

Solid Wall Hose:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EWP050SW

Introduction

:

Economically designed petrol powered water pump with recoil 

starting. Suitable for on site applications where mains power supply is 

not available. Featuring 50mm inlet/outlet with 26mtr pumping head 

offering a high flow rate up to 600ltr/min of water. Fitted on to frame 

with high density rubber shock absorbers, frame also aids with 

protection from accidental damage.

Fittings

:

1. 

Air filter cover

2. 

Air filter

3. 

Inlet/Outlet connector x 2

4. 

Connector locking ring x 2

5. 

Sealing washer  x 2

6. 

Wire pipe clamp x 3

7. 

Petrol tank cap

8. 

Filter basket

9. 

Filter basket cover

10.  Petrol tank filter

11.  Spark plug spanner bar

12.  Spark plug spanner

fig.1

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions and maintained properly, give you years of trouble free performance.

 

DO NOT

 block the engine ventilation grilles.

  Ensure engine fuel is stored in an approved container.

  For long term storage ensure the fuel is drained and that the  

 

pump is adequately protected against frost. 

 

DO NOT

 operate the engine with either the silencer or air filter  

 removed.

 

DO NOT

 touch the engine during or after use. To avoid burns  

 

allow it to cool before handling. 

EWP050     Issue :4(L) -10/07/17

© Jack Sealey Limited

    Original Language Version 

Содержание EWP050

Страница 1: ...ing and DO NOT remove the fuel cap whilst the engine is running DO NOT refuel the engine whilst it is running Stop the engine and allow it to cool for two minutes before attempting to refuel DO NOT refuel in a closed or poorly ventilated environment as there is a danger of explosion or fire Refuel out doors DO NOT smoke or place the pump near any naked flames whilst re fuelling DO NOT operate pump...

Страница 2: ...basket must be at least 0 3m below the surface of the water and 1 2m above the deepest part of the water to prevent debris blocking the filter basket See fig 3 Ensure that the suction pipe remains in the position intended 4 2 6 Ensure that the outlet pipe is correctly placed to discharge into the intended area 4 2 7 IMPORTANT Unscrew the cap from the priming port at the top of the pump and fill th...

Страница 3: ...very six months or every 100 hours of operation Change oil more often if engine is operated under heavy load or in high ambient air temperatures Top up with an SAE10W30 oil Failure to change the the oil according to the conditions defined above will invalidate your warranty 7 3 CHANGING THE OIL 7 3 1 Operate the engine for 3 minutes to warm the oil and then stop the engine using the shut down proc...

Страница 4: ... 7 7 SPARK PLUG To remove the spark plug pull off the spark plug lead fig 9 and remove the spark plug fig 12 using the spark plug wrench supplied fig 10 Note Care must be taken if the engine is hot due to the close proximity of the exhaust silencer to the spark plug 7 7 1 Clean spark plug using a wire brush and check the insulator for damage replace if damaged or at service schedule 7 7 2 Check th...

Страница 5: ... obstructed by foreign body Inspect and clear obstruction Loose rotary part Return to Sealey dealer for identification and replacement Unstable pump instalation Stop engine and consolidate position of unit Air in the pump or pipeline Stop engine open priming port to release air Impeller damaged Return to Sealey dealer for replacement Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds S...