background image

INSTRUCTIONS FOR:

DUAL ACTION SANDER

MODELS

:

DAS150T & DAS150T/DFS

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

DAS150T & DAS150T/DFS - 4 - 210405

IMPORTANT:

PLEASE READ INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.

USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.

SAFETY INSTRUCTIONS

1.1.

Electrical Safety 

p

p

WARNING!

It is the user’s responsibility to read, understand and comply with the following: 

You must

check all electrical equipment and appliances to ensure they are safe before using. 

You must

inspect power supply leads, plugs and all electrical connections for wear and damage. 

You must

ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An

RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend

that an RCD (Residual Current Device) is used with all electrical products. It is particularly important to use 

an RCD with portable products that are plugged into an electrical supply not protected by an RCCB. 

If in doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your 

Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises,

to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the

appliance and the safety of the appliance operator. If in doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply leads and plugs for wear and damage and all electrical connections to

ensure that none is loose. 

1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power supply to be

used and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse 

smaller than 13 amps for certain products, see fuse rating below. 

1.1.7.

DO NOT

pull or carry the appliance by the power supply lead.

1.1.8.

DO NOT

pull power plugs from sockets by the power cable.

1.1.9.

DO NOT

use worn or damaged leads, plugs or connections.

Immediately replace or have repaired by a qualified electrician.

A U.K. 3 pin plug with ASTA/BS approval is fitted. In case

of damage, cut off and fit a new plug according to the following

instructions, discard old plug safely (UK only - see diagram at right).  

Ensure the unit is correctly earthed via a three-pin plug. 

a) Connect the green/yellow earth wire to the earth terminal ‘E’.

b) Connect the brown live wire to live terminal ‘L’.

c) Connect the blue neutral wire to the neutral terminal ‘N’.

After wiring, check that there are no bare cores, that all wires

have been correctly connected, that the cable external insulation 

extends beyond the cable restraint and that the restraint is tight.

Double insulated products are fitted with live (BROWN) and neutral

(BLUE) wires only. Double insulated products are always marked 

with this symbol      . Check your model carefully to see which type

of product your have. To re-wire a double insulated item, connect

the brown and blue wires as indicated above. 

DO NOT

connect 

brown or blue to the earth terminal.

1.1.10. Cable extension reels. When a cable extension reel is used it should be fully unwound before connection.

A cable reel with an RCD fitted is recommended since any product which is plugged into the cable reel

will be protected. The section of the cores of the cable is important and should be at least 1.5mm

2

, but to

be absolutely sure that the capacity of the cable reel is suitable for this product and for others that may be

used in the other output sockets, we recommend the use of 2.5mm

2

section cable.

p

WARNING!

Ensure Health & Safety, local authority, and general workshop practice regulations 

are adhered to when using this equipment.

p

WARNING!

Disconnect from mains power before changing accessories or servicing.

Yellow & Green 

Earth Wire 

Brown

Live 

Wire

Blue

Neutral 

Wire

Cable

Restraint

01284 757500

01284 703534

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component

parts without prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this equipment. 

WARRANTY: 

Guarantee is 12

months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our latest catalogue and

promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor, Sealey Group

, Bury St. Edmunds, Suffolk.

Declaration of Conformity

We, the sole importer into the UK, declare that the products listed here are in conformity

with the following standards and directives. The construction files for these products are held by the Manufacturer and may be

inspected, by a national authority, upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK

of Sealey Power Tools.

DUAL ACTION SANDER Models: DAS150T & DAS150T/DFS

73/23/EEC Low Voltage Directive

89/336/EEC EMC Directive

98/37/EC Machinery Directive

93/68/EEC CE Marking Directive

15th April 2003

Issue:

3

Date Issued:

210405

5. PARTS LIST

6. DECLARATION OF CONFORMITY

Signed by Mark Sweetman

FUSE RATING

THIS PRODUCT MUST BE

FITTED WITH A

5 AMP FUSE

ITEM PART NO.

DESCRIPTION

1

ER1700P/01

LOCKING CAP

2

ER1700P/02

LOCKING PIN

3

ER1700P/03

SPRING

4

ER1700P/04

GEAR HOUSING

5

ER1700P/05

BRASS BUSHING

6

ER1700P/06

RETAINING RING

7

DAS150T/07

SPIRAL BEVEL GEAR

8

DAS150T/08

RETAINING RING

9

B/6201ZZ

BEARING

11

DAS150T/11

BEARING BOX

12

DAS150T/12

SCREW PAN HD M4x16 

c/w SPRING 

13

ER1700P/12

WOODRUFF KEY

14

DAS150T/14

SPINDLE

14-1 DAS150T/14-1 SCREW M6

15

DAS150T/15

ALUMINIUM COVER

16

DAS150T/16

ECCENTRIC SHAFT

18

DAS150T/18

RETAINING RING

19-3 DAS150T.PSK

PAD SPINDLE KIT

(PARTS 17/19/19-1/19-2)

20

ER1700P/20

SCREW

21

ER1700P/21

NUT

22

DAS150T/22

PINION GEAR

23

B/6000ZZ

BEARING

24

ER1700P/24

BEARING COVER

25

ER1700P/25

SCREW

27

DAS150T/27

ARMATURE ASS'Y

28

B/608LLB

BEARING

28-1 DAS150T.28-1

O-RING

29

ER1700P/29

SCREW

30

DAS150T/30

FIELD ASS'Y

31

ER1700P/31

MOTOR HOUSING

32

ER1700P/32

SWITCH LEVER

33

ER1700P/33

C’BON BRUSH HOLDER

34

ER1700P/34

CARBON BRUSH

35

ER1700P/35

CARBON BRUSH CAP

36

ER1700P/36

SWITCH BASE

37

ER1700P/37

SCREW

38

ER1700P/38

SWITCH

39

ER1700P/39

SCREW

40

ER1700P/40

STRAIN RELIEF

41

ER1700P/41

SCREW

42

ER1700P/42

SWITCH PULL ROD

43

ER1700P/43

SPRING

ITEM PART NO.

DESCRIPTION

44

ER1700P/44

CORD GUARD

46

CS 2.5M2CBLK POWER SUPPLY CORD

47

ER1700P/47

REAR COVER

48

ER1700P/48

SCREW

49

ER1700P/49

SIDE HANDLE

50

DAS150T/50

PAD

51

AK378/17S

17MM COMBI WRENCH

52

AK93-5

5MM HEX WRENCH

53

ER1700P/53-54 EMC PARTS

54

ER1700P/53-54 EMC PARTS

55

ER1700P/55

TERMINAL BLOCK

www.sealey.co.uk

Web

[email protected]

e-mail

1.2.

General  Safety

Отзывы: