Sealey AUTO SERVIC VS007.v3 Скачать руководство пользователя страница 1

InstructIons for: 

electronic stethoscope kit, 6 

channel

Model no: 

vs007.v3

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free 

performance.

1.  saFetY instrUctions

IMPORTANT:

 

please reaD these instrUctions careFUllY. note the saFe operational reQUireMents, WarninGs & caUtions. Use the proDUct 

correctlY anD With care For the pUrpose For Which it is intenDeD. FailUre to Do so MaY caUse DaMaGe anD/or personal inJUrY anD Will 

invaliDate the WarrantY. please keep instrUctions saFe For FUtUre Use.

check the content against the list below. If any items are missing or 

damaged contact your supplier.

• Stethoscope

• Stethoscope probe 

 

• Headphones

• Microphone Clamps x 6 

• Control Box 

2.  introDUction 

3.  content 

Original Language Version

Vs007.V3         Issue: 1 - 24/03/10

1.1. 

General saFetY

 

WarninG!

 

Ensure Health & Safety, local authority, and general  

  workshop practice regulations are adhered to when using this  

  equipment.

  familiarise yourself with the application and limitations of the  

  equipment, as well as the specific potential hazards.

 

Maintain the

 

equipment in good condition (use an authorised  

  service agent).

  replace or repair damaged parts. 

Use genuine parts only.  

  Unauthorised parts may be dangerous and will invalidate the  

  warranty.

  Keep the equipment clean for best and safest performance.

  Ensure cables, probe and clamps cannot contact moving parts.

 

Do not

 place cables, probe or clamps near high voltage items -  

  HT leads, spark plugs or ignition coil.

  Before road test ensure all cables are secure and, if they  

  become disconnected, cannot contact moving parts.

  When conducting a road test the 

driver must not

 operate the  

  Vs007.

 

Do not

 allow untrained persons to operate the Vs007.

 

Do not 

allow children to play with the Vs007.

 

Do not

 operate the equipment when you are tired or under the  

  influence of alcohol, drugs or  intoxicating medication.

  When not in use switch off equipment and store in a safe, dry,  

  childproof area.

  for prolonged storage remove batteries.

super-sensitive stethoscope, suitable for detection of faults in:

• Engine, Transmission.

• Cat Intake/Exhaust Manifold.

• Fuel Injectors, Radiators.

• Valves, Fuel Tanks.

Kit includes audio probe, headphones, six clip-on microphones and 

six-channel microphone selector box. Used by noise, harshness and 

vibration engineers to isolate problem sources. Enables vehicle to be 

road-tested and diagnosed simultaneously.