INSTRUCTIONS FOR
Digital VERNiER CalliPER
solaR PowERED
MODEL No:
aK9625EV
1. safEty iNstRuCtioNs
Hardened and tempered stainless steel dual powered digital calliper with satin finish. Solar powered but also with additional
battery cell (CR2016). When light is above 200LUX the solar panel will provide the power and below 200LUX the power will be
provided by the battery. Large LCD display for ease of reading. Metric and Imperial calibration with conversion between the two.
Zero setting control allows comparative measurement. Supplied in storage case.
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . 0-150mm / 0-6”
Resolution. . . . . . . . . . . . . . . . . . . . . . . . 0.01mm / 0.0005”
Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . 0.03mm / 0.001”
Cell Qty x Type. . . . . . . . . . . . . . . . . . . . 1 x CR2016
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT
PlEasE REaD tHEsE iNstRuCtioNs CaREfully. NotE tHE safE oPERatioNal REQuiREMENts, waRNiNgs,
aND CautioNs. usE tHis PRoDuCt CoRRECtly aND witH CaRE, foR tHE PuRPosE foR wHiCH it is iNtENDED. failuRE to
Do so May CausE DaMagE aND/oR PERsoNal iNJuRy aND will iNValiDatE tHE waRRaNty.
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to
when using tools and equipment.
Do Not
use if damaged.
Maintain calliper in good and clean condition for best performance.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the work area.
Do Not
use the calliper for any purpose other than for which it is designed.
Do Not
get calliper wet or use in damp or wet locations, or areas where there is condensation. Keep calliper clean and dry
using a dry cotton cloth only.
Do Not
dip or submerge the calliper in any type of liquid.
Do Not
expose calliper to bright sunlight or dust.
Do Not
disassemble. The calliper must be checked by qualified service personnel only.
Do Not
apply any voltage to the calliper i.e. with an electric marker pen.
The calliper is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.
Use in reasonably constant temperature conditions of approximately 20°C.
Take particular care not to damage or scratch the scale surface.
When not in use,
turn off
and store calliper in a safe, dry, childproof location.
1 - Internal Measuring Faces
5 - Metric (mm)/Imperial (inch) Button
9 - Solar Panel
2 - Step Measuring Faces
6 - On/Off Button
10 - Battery Compartment
3 - External Measuring Faces
7 - Zero Button
11 - Depth Gauge
4 - LCD
8 - Lock Screw
fig.1
2. iNtRoDuCtioN & sPECifiCatioN