SeaLevel PC-SIO-850 Скачать руководство пользователя страница 1

 

© Sealevel Systems, Inc.  3604 Manual   |   SL9112   10/2022 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC-SIO-850 

User Manual  |  3604 

Содержание PC-SIO-850

Страница 1: ...1 Sealevel Systems Inc 3604 Manual SL9112 10 2022 PC SIO 850 User Manual 3604 ...

Страница 2: ...tents CONTENTS 2 INTRODUCTION 3 BEFORE YOU GET STARTED 4 CARD SETUP 5 TECHNICAL DESCRIPTION 7 SPECIFICATIONS 8 APPENDIX A TROUBLESHOOTING 9 APPENDIX B HOW TO GET ASSISTANCE 10 APPENDIX C ELECTRICAL INTERFACE 11 APPENDIX D COMPLIANCE NOTICES 12 WARRANTY 13 ...

Страница 3: ...tandards organizations JEIDA and PCMCIA were working on the standardization of memory IC cards These cards were designed as strictly non volatile silicon storage JEIDA was the first to propose the 68 pin connector standard for memory cards In 1989 PCMCIA adopted the JEIDA 68 pin standard and worked with JEIDA on further developments As the notebook market grew the need for a standard I O bus was s...

Страница 4: ...t Resistant Carrying Case Jewel Case Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail Note The lowest level of importance used to...

Страница 5: ...e computer system should provide adequate support for most applications A DOS Enabler is also provided for older systems in which the Generic Enabler isn t adequate Please refer to Appendix C for information on the SEAPC enabler and the diagnostic tool SSEnable Connecting the PC SIO 850 to the computer requires no special technical skills In fact it is usually done in as simple as two steps 1 Foll...

Страница 6: ...400 bps 600 bps 4800 bps 1200 bps 9600 bps 2400 bps 19 2K bps 4800 bps 57 6 K bps 9600 bps 115 2 K bps 19 2K bps 230 4K bps 57 6 K bps 460 8K bps 115 2 K bps If your communications package allows the use of Baud rate divisors choose the appropriate divisor from the following table For this Data Rate Choose this Divisor 1200 bps 384 2400 bps 192 4800 bps 96 9600 bps 48 19 2K bps 24 38 4K bps 12 57 ...

Страница 7: ...ections and software specific changes Each COM Port requires a minimum of one block of eight I O addresses For example COM1 is usually hex address 3F8 3F8 is the base address and the COM ports extend through 3FF In most applications each COM port will utilize one IRQ Connector Pin Assignments for RS 232 DB 25 and DB 9 Male Signal Name DB 25 DB 9 Mode GND Ground 7 5 TD Transmit Data 2 3 Output RTS ...

Страница 8: ...ing 10 to 90 R H Non Condensing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel Power Requirements Supply line 5 VDC Rating mA 25 mA Physical Dimensions The PC SIO 580 conforms to the physical dimensions for all PCMCIA Type II cards as d...

Страница 9: ...not 4 Make sure the Sealevel Systems adapter is securely installed in the PC Card Slot 5 When running DOS or Windows refer to the available Sealevel Software and this User Manual to verify that the Sealevel Systems adapter is configured correctly The software contains a diagnostic program SSD which will verify if an adapter is configured properly This diagnostic program is written with the user in...

Страница 10: ... web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp 4 Sealevel Systems maintains a web page on the Internet Our home page address is www sealevel com The latest software updates and newest manuals are available via our web site 5 Technical support is available Monday to Friday from 8 00 A M to 5 00 P M Eastern Time Technical sup...

Страница 11: ...despread use and will be referred to as RS 232 in this document RS 232 is capable of operating at data rates up to 20 Kbps at distances less than 50 ft The absolute maximum data rate may vary due to line conditions and cable lengths RS 232 often operates at 38 4 Kbps over very short distances The voltage levels defined by RS 232 range from 12 to 12 volts RS 232 is a single ended or unbalanced inte...

Страница 12: ... user will be required to correct the interference at his own expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of measurement of radio interference ...

Страница 13: ...r this warranty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warranty is valid only for original purchaser and is not transferable This warranty applies to Seal...