SeaLevel 3093H Скачать руководство пользователя страница 1

 

© Sealevel Systems, Inc.  3093H Manual   |   SL9024H  12/2022 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIO-32B 

User Manual  |  3093H 

Содержание 3093H

Страница 1: ...1 Sealevel Systems Inc 3093H Manual SL9024H 12 2022 DIO 32B User Manual 3093H ...

Страница 2: ...TED 4 CARD SETUP 6 SOFTWARE INSTALLATION 8 PHYSICAL INSTALLATION 9 PROGRAMMING THE DIO 32B 10 ELECTRICAL CHARACTERISTICS 15 SPECIFICATIONS 15 EXAMPLE CIRCUITS 17 APPENDIX A TROUBLESHOOTING 18 APPENDIX B HOW TO GET ASSISTANCE 19 APPENDIX C SILK SCREEN 3093H PCB 20 APPENDIX D COMPLIANCE NOTICES 21 WARRANTY 22 ...

Страница 3: ...ose when energized The DIO 32B is designed to be used with a variety of Operating Systems including Windows 98 NT ME 2000 XP Linux and DOS The SeaI O API Application Programmer Interface available for the DIO 32B provides a variety of useful high level function calls implemented as a Windows dynamic link library DLL and as a Linux kernel module and library In addition to the API SeaI O includes sa...

Страница 4: ... to DB 37 Male Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail Note The lowest level of importance used to provide background in...

Страница 5: ...his cable provides a 6 extension to the CA165 It has one DB37 Male connector and one DB37 Female connector DB 37 Male Female Terminal Block Item TB02 KT Break out serial and digital connectors to screw terminals for easy field connection The TB02 terminal block is designed with both DB37 male and female connectors therefore it can be used with any DB37 board regardless of the board s port gender C...

Страница 6: ...x Off On Off On On On On On 284 287 10 1000 01xx Off On Off On Off On On Off 2EC 2EF 10 1110 11xx Off On Off Off Off On Off Off 300 303 11 0000 00xx Off Off On On On On On On 320 323 11 0010 00xx Off Off On On Off On On On 388 38B 11 1000 10xx Off Off Off On On On Off On 3A0 3A3 11 1010 00xx Off Off Off On Off On On On 3A4 3A7 11 1010 01xx Off Off Off On Off On On Off Address Selection Table The f...

Страница 7: ...rt A bit 0 going low if enabled at jumper location E2 Interrupt request signals 2 9 through 7 IRQ 2 9 7 can be selected by placing the jumper in the appropriate position Other inputs can be wire OR ed to also generate interrupts if desired Please consult the factory for more information IRQ Header E2 ...

Страница 8: ...the operating parameters for each driver An uninstall option is also available to remove SeaIO files and registry INI file entries from the system 2 A screen may appear with the declaration The publisher cannot be determined due to the problems below Authenticode signature not found Please select the Yes button and proceed with the installation This declaration simply means that the Operating Syst...

Страница 9: ...ank metal slot cover 4 Gently insert the PCI adapter into the slot Make sure that the adapter is seated properly 5 After the adapter has been installed the cables should be routed thru the opening in the bracket This bracket also features a strain relief function that should be used to prevent un expected cable removal 6 Replace the screw you removed for the blank and use it to secure the adapter ...

Страница 10: ...ion Description If you have any problems locating these files please contact Sealevel s Technical Support at 864 843 4343 or email support sealevel com Programming for Linux SeaI O for Linux consists of two major parts a kernel module and a library The kernel module is a simple IO pass through device allowing the library to handle the more sophisticated functions provided to SeaI O users It is pro...

Страница 11: ...proximately 3 3K ohms factory default The opto isolator requires approximately 3mA to turn on The maximum input current is 50mA There are two things to consider when selecting the input resistor The first is turn on voltage for the circuit to sense and second is the maximum input voltage Maximum input voltage must not provide too much power to the input resistor and must also not overdrive the opt...

Страница 12: ...ormally open and close when energized Output Ports Reed Relay Pin Assignments CA111 Outputs are interfaced via the DB 37 male connector on the supplied connector cable item CA111 Port C Bit Relay Port C Pins Port D Bit Relay Port D Pins 0 K16 2 20 0 K8 10 28 1 K15 3 21 1 K7 11 29 2 K14 4 22 2 K6 12 30 3 K13 5 23 3 K5 13 31 4 K12 6 24 4 K4 14 32 5 K11 7 25 5 K3 15 33 6 K10 8 26 6 K2 16 34 7 K9 9 27...

Страница 13: ...des port numbers are zero indexed that is the first port is port 0 the second port is 1 the third 2 and so on Direct Hardware Control In systems where the users program has direct access to the hardware DOS the tables that follow give the mapping and functions that the DIO 32B provides Function Available Port Address Hex Port Type RD A Base 0 RD B Base 1 Optically Isolated Input Port RD WR C Base ...

Страница 14: ...pt enable 1 enabled 0 disabled 0 on power up IRC0 IRC1 Interrupt mode select see table below Interrupt mode select see table below Interrupt Mode Select Table Interrupt source is Base 0 bit D0 When selecting the Interrupt Type always disable interrupts prior to changing or setting states This will help prevent inadvertent or unexpected interrupts from occurring IRC1 IRC0 Interrupt Type 0 0 Low Lev...

Страница 15: ...ress data and control signals are TTL compatible Specifications Input Ports Turn On Current 3mA Isolator Diode Drop 1 1 VDC Resistor Power Max 25W Maximum Input Range 10 30 VDC VAC Outputs Relays Contact Max Power Rating 10 W Contact Voltage Maximum 100 VDC VAC Contact Current Maximum 5A AC DC RMS Contact Resistance Initial 15 Ω Rated Life Low Load Maximum Load 200 Million Closures 100 Million Clo...

Страница 16: ...VDC 12 VDC Rating 800 mA 50 mA Physical Dimensions PCB Length 9 8 Inches 24 8 cm PCB Height 4 2 inches 10 7 cm including Goldfingers Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel ...

Страница 17: ...17 Sealevel Systems Inc 3093H Manual SL9024H 12 2022 Example Circuits Input Circuit Output Circuit ...

Страница 18: ...O Control Panel applet or the Device Manager s property page for card identification and configuration 5 The following are known I O conflicts The 278 and 378 settings may conflict with your printer I O adapter 3B0 cannot be used if a Monochrome adapter is installed 3F8 3FF is typically reserved for COM1 2F8 2FF is typically reserved for COM2 3E8 3EF is typically reserved for COM3 2E8 2EF is typic...

Страница 19: ...tions This section can be found at http www sealevel com faq asp Sealevel Systems maintains a Home page on the Internet Our home page address is www sealevel com The latest software updates and newest manuals are available via our FTP site that can be accessed from our home page Technical support is available Monday to Friday from 8 00 AM to 5 00 PM Eastern Time Technical support can be reached at...

Страница 20: ...20 Sealevel Systems Inc 3093H Manual SL9024H 12 2022 Appendix C Silk Screen 3093H PCB 9 75 4 2 3 9 ...

Страница 21: ...red to correct the interference at the users expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of measurement of radio interference characteristics o...

Страница 22: ...anty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warranty is valid only for original purchaser and is not transferable This warranty applies to Sealevel manufa...