Section 4. Maintenance & Troubleshooting
SLCT-FAL5645 Sealing Machine
© Sealed Air Corporation (US)
MM-0110; Revision 1-A: 11/01/2013
4-8
Item
Problem
Possible Causes
Recommended Action
6
Front conveyor motor
does not work
The connecting point [1001] of
PLC is not functioning
Change the connecting
point [1001] and the
program of PLC or Change
the PLC
The relay of front conveyor
motor is not functioning
Change the relay of front
conveyor motor
The front conveyor motor is
overloaded or overheated
Remove the cause and
restart the system
The front conveyor motor is
not functioning
Change the front conveyor
motor
7
Rear conveyor motor
does not work
The connecting point [1002] of
PLC is not functioning
Change the connecting
point [1002] and the
program of PLC or Change
the PLC
Relay of rear conveyor motor
is not functioning
Replace the relay of rear
conveyor motor
The rear conveyor motor is
overloaded or overheated
Remove the cause and
restart the system
The rear conveyor motor is not
functioning
Replace the rear conveyor
motor
8
The wasted fi lm
receiving motor does
not work
The connecting point [1003] of
PLC is not functioning
Change the connecting
point [1003] and the
program of PLC or Change
the PLC
Relay of the wasted fi lm motor
is not functioning
Change the relay of the
wasted fi lm motor
Manual fi lm conveying switch
is not functioning
Change the manual fi lm
conveying switch
The wasted fi lm motor is over
loaded or overheated
Remove the cause and
restart the system
The wasted fi lm motor is not
functioning
Change the wasted fi lm
motor
9
The sealing base unit
does not work
The connecting point [1004] of
PLC is not functioning
Change the connecting
point [1004] and the
program of PLC or Change
the PLC
The manual sealing operation
switch is not functioning
Change the manual sealing
operation switch
Содержание SeleCTech