Section 2. General Information
SLCT-FAL5645 Sealing Machine
© Sealed Air Corporation (US)
MM-0110; Revision 1-A: 11/01/2013
2-3
2.1 SELECT THE MACHINE INSTALLATION LOCATION
The sealing machine should placed well-lit and dry place. It should be positioned away from
dusty, fl ammable, explosive and corrosive areas.
Placing the sealing machine too close to the ventilation system may cause unstable fi lm delivery.
.
2.2 LEVELING THE SEALING MACHINE
Refer to Figure 2-1 for the following system leveling/height adjustment procedure. The steps
apply to all four (4) feet on the base of the system.
1. Use a spanner to loosen the lock nut (1) at the sealing machine base.
2. Use a spanner to
turn the nut on the height adjustment screw
(2)
. When the sealing machine
is at the required height, tighten the lock nut
(1) up
to the base of the machine.
Figure 2–1 Sealing Machine Leveling/Height Adjustment