14
Note
:
1.
A
4"
wide label paper is required to print all debugging mode data
2.
Turn off and on the power to leave the debugging mode and return to the normal printing
mode, or press the
FEED
button to return to the standby state.
4.3.3 Printer initialization
The printer initialization function is to clear the downloaded files in the memory (DRAM) and restore
the print parameters to the factory default settings.
Please follow the steps below to complete the initialization:
1. Turn off the power
2. Hold down the feed button and turn on the power. At this point, the power indicator light color will
cycle as follows
Indicator color cycle mode:
Purple
Blue
Red (5 flashes)
Purple (5 flashes)
Blue (5 flashes)
Blue (fixed)
3. Release the feed button when the power indicator is flashing blue. At this point, the printer will be
reset, and then the power indicator will flash purple once, and finally the indicator will be blue
ready.
After initialization, the printer configuration is restored to its default values as follows:
Parameters
Defaults
Speed
127 mm/sec (5 ips) (203DPI)
Density
8
Label width
3.15” (80 mm)
Label height
7.9” (180 mm)
Sensor type
Gap sensor
Gap setting
0.16” (4.0 mm)
Printing direction
0
Reference point
0,0 (upper left corner)
Offset
0
Tear-off mode
On
Peel-off mode
Off
Characters
850
Country code
001
Clear flash
No