OneStor® SP-3584 Installation & User Guide
34
5
Verify that the device driver for the operating system has been installed correctly.
5.3 LEDs
LED colors are used consistently throughout the enclosure and its components for indicating status:
• Green – good or positive indication.
• Flashing green/amber – non-critical condition.
• Amber – fault.
Note
When the enclosure is powered on, all LEDs are lit for a short period to ensure that they are working.
This does not indicate a fault unless the LEDs remain lit after a few seconds.
5.3.1 PSU LEDs
Figure 5–1
PSU LEDs
Table 5–1
PSU LED States
PSU Fail
(Amber)
AC Missing
(Amber)
Power
(Green)
Status
Off
Off
Off
No AC power to either PSU.
On
On
Off
PSU present, but not supplying power
or
PSU alert state
(usually due to critical temperature).
Off
Off
On
Mains AC present, switch on. This PSU is providing power.
Off
Off
Flashing
AC power present, PSU in standby (other PSU is providing
power).
Flashing
Flashing
Off
PSU firmware download.
Off
On
Off
AC power missing, PSU in standby (other PSU is providing
power).
On
On
On
GEM software has lost communication with the PSU.
On
–
Off
PSU has failed. Follow the procedure in section
6.5, “Replacing a Power Supply Unit (PSU)”, on page 51
.
Содержание OneStor SP-3584
Страница 1: ...OneStor SP 3584 Installation User Guide Part No 83 00007099 10 01 Revision B June 2017 ...
Страница 6: ...vi OneStor SP 3584 Installation User Guide ...
Страница 8: ...OneStor SP 3584 Installation User Guide viii ...
Страница 14: ...OneStor SP 3584 Installation User Guide 6 ...
Страница 33: ...Installation 25 Figure 3 4 Valid Configuration ...
Страница 64: ...OneStor SP 3584 Installation User Guide 56 ...
Страница 76: ...OneStor SP 3584 Installation User Guide 68 ...