Seagate EXOS ST4000NM000A Скачать руководство пользователя страница 13

Seagate Exos 7E8 SATA Product Manual, Rev. B (Draft 2)

  12

  

2.5.2

Conducted noise

Input noise ripple is measured at the host system power supply across an equivalent 80-ohm resistive load on the +12 V line or an

 

equivalent 15-ohm resistive load on the +5V line.
• Using 12V power, the drive is expected to operate with a maximum of 120mV peak-to-peak square-wave injected noise at up to

 

10MHz.

• Using 5V power, the drive is expected to operate with a maximum of

 

100mV peak-to-peak square-wave injected noise at up to

 

10MHz.

2.5.3

Voltage tolerance

Voltage tolerance (including noise):

5V   +10/ -5%

12V ± 10%

2.5.4

Extended Power Conditions - PowerChoice

TM

Utilizing the load/unload architecture a programmable power management interface is provided to tailor systems for reduced

 

power consumption and performance requirements. 

The table below lists the supported power conditions available in PowerChoice. Power conditions are ordered from highest power 
consumption (and shortest recovery time) to lowest power consumption (and longest recovery time) as follows: Idle_a power >=

 

Idle_b power >= Idle_c power >= Standby_z power. The further users go down in the table, the more power savings is actualized. For 
example, Idle_b results in greater power savings than the Idle_a power condition. Standby results in the greatest power savings. 

Each power condition has a set of current, saved and default settings. Default settings are not modifiable. Default and saved settings 
persist across power-on resets. The current settings do not persist across power-on resets. At the time of manufacture, the default, 
saved and current settings are in the Power Conditions log match.

PowerChoice is invoked using one of two methods

• Automatic power transitions which are triggered by expiration of individual power condition timers. These timer values may be

 

customized and enabled using the Extended Power Conditions (EPC) feature set using the standardized Set Features command

 

interface.

• Immediate host commanded power transitions may be initiated using an EPC Set Features "Go to Power Condition" subcommand

 

to enter any supported power condition. Legacy power commands Standby Immediate and Idle Immediate also provide a

 

method to directly transition the drive into supported power conditions. 

PowerChoice exits power saving states under the following conditions

• Any command which requires the drive to enter the PM0: Active state (media access)
• Power  on  reset

PowerChoice provides the following reporting methods for tracking purposes

Check Power Mode Command 
• Reports the current power state of the drive

Identify Device Command
• EPC Feature set supported flag
• EPC Feature enabled flag is set if at least one Idle power condition timer is enabled

Note

Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write current.

Power Condition Name

Power Condition ID

Description

Idle_a

81

H

Reduced electronics

Idle_b

82

H

Heads unloaded. Disks spinning at full RPM

Idle_c

83

H

Heads unloaded. Disks spinning at reduced RPM

Standby_z

00

H

Heads unloaded. Motor stopped (disks not spinning)

Содержание EXOS ST4000NM000A

Страница 1: ...Standard 512N models ST4000NM0035 ST3000NM0005 ST2000NM0055 ST1000NM0055 Self Encryption 512N models ST4000NM0045 ST3000NM0015 ST2000NM0065 ST1000NM0065 SED FIPS 140 2 512N models ST4000NM0105 ST3000N...

Страница 2: ...s one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating system may use a different standard of measurement and report a lower capacity In addition some of the li...

Страница 3: ...15 2 6 5 Vibration 15 2 7 Acoustics 15 2 8 Test for Prominent Discrete Tones PDTs 16 2 9 Electromagnetic immunity 16 2 10 Reliability 16 2 10 1 Annualized Failure Rate AFR and Mean Time Between Failur...

Страница 4: ...23 4 2 3 Default password 23 4 3 Random number generator RNG 24 4 4 Drive locking 24 4 5 Data bands 24 4 6 Cryptographic erase 24 4 7 Authenticated firmware download 24 4 8 Power requirements 25 4 9 S...

Страница 5: ...cts For information regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery services visit http www seagate com services softwar...

Страница 6: ...disk drive in the current system and expect all of the existing applications to work as normal The Serial ATA interface connects each disk drive in a point to point configuration with the Serial ATA...

Страница 7: ...ogical sector 512 Recording density KBPI Kb in max 2018 Track density KTPI ktracks in avg 369 Areal density Gb in2 avg 732 Spindle speed RPM 7200 Internal data transfer rate Mb s max 2396 Sustained da...

Страница 8: ...60 POH Maximum Rated Workload Maximum rate of 550TB year Workloads exceeding the annualized rate may degrade the drive MTBF and impact product reliability The Annualized Workload Rate is in units of T...

Страница 9: ...Recording and interface technology 2 4 Start stop times ST models Formatted capacity Guaranteed sectors Bytes per logical sector ST4000NM0035 ST4000NM0045 ST4000NM0105 4TB 7 814 037 168 512 ST3000NM0...

Страница 10: ...er to operational levels Table 2 DC power requirements 3TB and 4TB 6 0Gb mode Voltage 5V 12V Watts Regulation 5 Total Avg Idle Current 0 205 0 369 5 45 Advanced Idle Current Idle_A 0 200 0 366 5 39 Id...

Страница 11: ...0 270 4 22 Idle_B 0 128 0 244 3 57 Idle_C 0 137 0 156 2 56 Standby 0 120 0 011 0 74 Maximum Start Current DC peak DC 0 466 2 046 AC Peak DC 0 608 2 72 Delayed Motor Start DC max 0 144 0 02 0 96 Opera...

Страница 12: ...Manual Rev B Draft 2 11 2 5 1 1 Typical current profiles Figure 1 4TB Typical 5V and 12V startup and operation current profile 2 5 1 2 Typical current profiles Figure 2 2TB Typical 5V and 12V startup...

Страница 13: ...gs persist across power on resets The current settings do not persist across power on resets At the time of manufacture the default saved and current settings are in the Power Conditions log match Pow...

Страница 14: ...a timer values less than the specified minimum timer value threshold will result in an aborted EPC Set Power Condition Timer subcommand Setting power condition timer values less than the manufacturer...

Страница 15: ...the case temperature of the drive See Figure 3 for HDA temperature checkpoint b Non operating 40 to 158 F 40 to 70 C package ambient with a maximum gradient of 36 F 20 C per hour This specification as...

Страница 16: ...formance standards specified in this document are specified below Rotary Random Operating Vibration 2 6 5 2 Non operating vibration The maximum non operating vibration levels that the drive may experi...

Страница 17: ...TBF conditions and the maximum drive operating conditions may occur without significant impact to the rated MTBF However continual or sustained operation beyond the rated MTBF conditions will degrade...

Страница 18: ...e Section 2 12 1 on page 18 2 11 3 Australian RCM Compliance Mark If these models have the RCM marking they comply with the Australia New Zealand Standard AS NZ CISPR32 and meet the Electromagnetic Co...

Страница 19: ...are on different branch outlets If necessary users should consult a dealer or an experienced radio television technician for additional suggestions Users may find helpful the following booklet prepare...

Страница 20: ...CNS 15663 effective January 1 2018 This product is Taiwan RoHS compliant The following table meets the Section 5 Marking of presence requirements Table 6 China Hazardous Substances Part Name Hazardou...

Страница 21: ...s to function properly under normal use due to defect in materials or workmanship or due to nonconformance to the applicable specifications will be repaired or replaced at Seagate s option and at no c...

Страница 22: ...an connect the drive as illustrated in Figure 4 Figure 4 Attaching SATA cabling Each cable is keyed to ensure correct orientation Seagate Exos 7E8 SATA drives support latching SATA connectors 3 4 Driv...

Страница 23: ...found at www sffcommittee org Note The image is for mechanical dimension reference only and may not represent the actual drive 2X 1 750 010 2X 1 625 010 4 000 010 3 750 010 1 432 019 2 128 010 814 020...

Страница 24: ...encrypted when it is stored on the media and when it is in volatile temporary storage DRAM external to the encryption engine A unique data encryption key is used for each of the drive s possible16 da...

Страница 25: ...a Bands may be defined in a similar way Band2 through Band31 but before these bands can be allocated LBA space they must first be individually enabled using the EraseMaster password Data bands cannot...

Страница 26: ...barcode 4 11 ATA Security Erase Unit Command on SED SATA drives The ATA SECURITY ERASE UNIT command shall support both the Normal and Enhanced erase modes with the following modifications additions No...

Страница 27: ...operate in FIPS Approved Mode of Operation these SEDs require security initialization For more information refer to Security Rules section in the Security Policy document uploaded on the NIST website...

Страница 28: ...he ground pins P4 and P12 the pre charge power pins and the other ground pins the signal pins and the rest of the power pins 3 There are three power pins for each voltage One pin from each voltage is...

Страница 29: ...Power Mode E5H Download Microcode 92H Execute Device Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Identify Device ECH Idle E3H Idle Immediate E1H NoP 00H Read Buffer E4H Read Buffer DMA E...

Страница 30: ...Save Attribute Values B0H D3H S M A R T Write Log Sector B0H D6H Standby E2H Standby Immediate E0H Trusted Send 5EH SED drives only Trusted Send DMA 5FH SED drives only Trusted Receive 5CH SED drives...

Страница 31: ...vision 8 ASCII character string padded with blanks to end of string xxxx 27 46 Drive model number 40 ASCII characters padded with blanks to end of string 47 Bits 7 0 Maximum sectors per interrupt on R...

Страница 32: ...3H 88 Ultra DMA support and current mode see note following this table 207FH 89 Security erase time xxxxH 90 Enhanced security erase time xxxxH 92 Master password revision code FFFEH 93 Hardware reset...

Страница 33: ...Card Pass Through Command feature set is supported 4 Streaming feature set is supported 5 GPL feature set is supported 6 WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands are supported 7 WRITE DM...

Страница 34: ...t transfer mode based on value in Sector Count register Sector Count register values 00H Set PIO mode to default PIO mode 2 01H Set PIO mode to default and disable IORDY PIO mode 2 08H PIO mode 0 09H...

Страница 35: ...cessary drive returns The diagnostic software ships with all new drives and is also available at http www seagate com support downloads seatools This drive is shipped with S M A R T features disabled...

Страница 36: ...States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16 18...

Отзывы: