22
Elite 9 Product Manual, Rev. C
To confirm that required cooling for the Elite electronics and HDA is provided,
place the drive in its final mechanical configuration, perform random write/
read operations; and after the temperatures stabilize, measure the case
temperature of the components listed below.
Maximum allowable operating temperatures are listed in the last column.
Operation above these values may adversely affect the drive’s ability to
meet functional specifications.
Air-flow cooling
MTBF
500k hours
Card
Component
Reference
case temperature (°C)
R/T/U/CYHX
Transmitter
U5
45
R/T/U/CYHX
Writer
U35
46
R/T/U/CYHX
VIC2
U20
44
R/T/U/CYHX
VOLT MON
U56
43
R/T/U/CYHX
DRAM
U3
41
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocity was 200 lfpm and
inlet air temperature to the drive was 30°C (86°F).
The maximum allowable HDA case temperature is 55°C.
J06
U1
U5
J15
U12
U33
J17
U10
U13
J12
U58
U4
U20
U35
U34
U28
U56
J30
J23
U28
U23
U14
U2
U3
J18
J4B
J4A
Figure 7. R/T/U/CYHX temperature measurement locations
Содержание Elite 9
Страница 1: ...Elite 9 Disc Drive ST410800N ND ST410800W WD Product Manual Volume 1...
Страница 2: ......
Страница 3: ...Elite 9 Disc Drive ST410800N ND ST410800W WD Product Manual Volume 1...
Страница 6: ......
Страница 12: ...2 Elite 9 Product Manual Rev C...
Страница 14: ...4 Elite 9 Product Manual Rev C...
Страница 20: ...10 Elite 9 Product Manual Rev C...
Страница 34: ...24 Elite 9 Product Manual Rev C...
Страница 44: ...34 Elite 9 Product Manual Rev C...
Страница 46: ...36 Elite 9 Product Manual Rev C...
Страница 48: ...38 Elite 9 Product Manual Rev C...
Страница 54: ...44 Elite 9 Product Manual Rev C...
Страница 81: ...Elite 9 Product Manual Rev C 71...