background image

Seagate BarraCuda Pro v6 Serial ATA Product Manual, Rev. A

  29

  

4.3

Supported ATA commands

The following table lists Serial ATA standard commands that the drive supports. For a detailed description of the ATA commands, 
refer to the Serial ATA: High Speed Serialized AT Attachment specification

See “S.M.A.R.T. commands” on page 35.for details and

 

subcommands used in the S.M.A.R.T. implementation.

Table 10 Supported ATA commands

Command name

Command code (in hex)

Accessible Max Address Configuration

Get Native Max Address Ext

78

H

 / 0000

H

Set Accessible Max Address Ext

78

H

 / 0001

H

Freeze Accessible Max Address Ext

78

H

 / 0002

H

Check Power Mode

E5

H

Download Microcode

92

H

Execute Device Diagnostics

90

H

Flush Cache

E7

H

Flush Cache Extended

EA

H

Identify Device

EC

H

Idle

E3

H

Idle Immediate

E1

H

NoP

00

H

Read Buffer

E4

H

Read Buffer DMA

E9

H

Read DMA

C8

H

Read DMA Extended

25

H

Read FPDMA Queued

60

H

Read Log DMA Ext

47

H

Read Log Ext

2F

H

Read Multiple

C4

H

Read Multiple Extended

29

H

Read Sectors 

20

H

Read Sectors Extended

24

H

Read Sectors Without Retries

21

H

Read Verify Sectors 

40

H

Read Verify Sectors Extended

42

H

Read Verify Sectors Without Retries

41

H

Request Sense Data Ext

0B

H

Sanitize Device - Overwrite Ext

B4

H

 / 0014

H

Sanitize Device - Freeze Lock Ext

B4

H

 / 0020

H

Sanitize Device - Status Ext

B4

H

 / 0000

H

Security Disable Password

F6

H

Security Erase Prepare

F3

H

Security Erase Unit

F4

H

Security Freeze

F5

H

Security Set Password

F1

H

Security Unlock

F2

H

Содержание BarraCuda Pro ST2000DX003

Страница 1: ...100811076 Rev A October 2016 Standard models ST8000DM005 ST6000DM004 ST4000DX003 ST2000DX003 v6 SATA Product Manual...

Страница 2: ...ferring to drive capacity one gigabyte or GB equals one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating system may use a different standard of measurement and...

Страница 3: ...10 1 Annualized Failure Rate AFR and Mean Time Between Failures MTBF 18 2 10 2 Seagate Rescue Data Recovery Service Program Terms for Rescue models 18 2 11 Agency certification 20 2 11 1 Safety certif...

Страница 4: ...or information regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery services visit http www seagate com services software dat...

Страница 5: ...erial ATA host adapter and Serial ATA disk drive in the current system and expect all of the existing applications to work as normal The Serial ATA interface connects each disk drive in a point to poi...

Страница 6: ...s in avg 369 330 Areal density Gb in2 avg 732 651 Spindle speed RPM 7200 Internal data transfer rate Mb s max 2396 2585 Maximum Sustained data transfer rate OD 214 MB s 195 MB s I O data transfer rate...

Страница 7: ...rads s Vibration non operating Random psd 2 500 Hz 2Hz 001g2 Hz 4Hz 03g2 Hz 100Hz 03g2 Hz 500Hz 001g2 Hz Drive acoustics sound power bels Idle 2 8 typical 3 0 max Performance seek 3 2 typical 3 4 max...

Страница 8: ...30 17 Ready to spindle stop sec max 23 12 Models 8TB 6TB 4TB 2TB Interface Serial ATA SATA Recording method Perpendicular Recording density KBPI Kb in max 2018 1936 Track density KTPI ktracks in avg 3...

Страница 9: ...coustic and power to operational levels Table 2 DC power requirements 8TB 6 0Gb mode Voltage 5V 12V Watts Regulation 5 Total Avg Idle Current 0 33 0 58 8 63 Advanced Idle Current Idle_A 0 19 0 55 7 53...

Страница 10: ...22 0 474 7 80 Idle_B 0 327 0 392 6 33 Idle_C 0 335 0 235 4 49 Standby 0 317 0 007 1 66 Maximum Start Current DC peak DC 0 716 2 0 AC Peak DC 0 752 2 92 Delayed Motor Start DC max 0 40 0 012 2 14 Peak...

Страница 11: ...200 0 393 5 70 Idle_B 0 133 0 330 4 63 Idle_C 0 141 0 202 3 13 Standby 0 125 0 001 0 63 Maximum Start Current DC peak DC 0 491 2 0 AC Peak DC 0 680 2 680 Delayed Motor Start DC max 0 176 0 068 1 70 Pe...

Страница 12: ...e Current 0 288 0 267 4 64 Advanced Idle Current Idle_A 0 287 0 265 4 61 Idle_B 0 172 0 236 3 70 Idle_C 0 181 0 145 2 64 Standby 0 162 0 000 0 82 Peak operating current random read Typical DC 0 311 0...

Страница 13: ...line or an equivalent 15 ohm resistive load on the 5V line Using 12V power the drive is expected to operate with a maximum of 120mV peak to peak square wave injected noise at up to 10MHz Using 5V pow...

Страница 14: ...omized and enabled using the Extended Power Conditions EPC feature set using the standardized Set Features command interface Immediate host commanded power transitions may be initiated using an EPC Se...

Страница 15: ...ssuing the EPC Go to Power Condition subcommand at a rate exceeding the default timers may limit this products reliability and data integrity PowerChoice Supported Extended Power Condition Feature Sub...

Страница 16: ...nt b Non operating 40 to 158 F 40 to 70 C package ambient with a maximum gradient of 36 F 20 C per hour This specification assumes that the drive is packaged in the shipping container designed by Seag...

Страница 17: ...shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 300 Gs based on a nonrepetitive half sine shock pulse...

Страница 18: ...radation in performance when subjected to the radio frequency RF environments defined in the following table Note For seek mode tests the drive is placed in seek mode only The number of seeks per seco...

Страница 19: ...bility and to assess whether your data may be recoverable by remote recovery services or whether you will need to send your device to SRS for in lab servicing Rescue General Terms These Rescue General...

Страница 20: ...ACT BREACH OF CONTRACT AND TORT AND REGARDLESS OF WHETHER WE HAVE BEEN ADVISED OF THE POSSIBILITY OF LOSS OR DAMAGES UNLESS YOU PROVE THAT SRS CAUSED DAMAGES TO YOU INTENTIONALLY TO THE MAXIMUM EXTENT...

Страница 21: ...change your rights under applicable law if such laws do not permit these Program Terms to do so Also the Program and these Program Terms are in addition and unrelated to any rights you may have under...

Страница 22: ...sult in interference to radio and television reception Radio and television interference This equipment generates and uses radio frequency energy and if not installed and used in strict accordance wit...

Страница 23: ...silver copper nickel and gold films used in hard disk drives are especially sensitive to the presence of sulfide chloride and nitrate contaminants Sulfur is found to be the most damaging Materials us...

Страница 24: ...n transporting or shipping a drive use only a Seagate approved container Keep the original box Seagate approved containers are easily identified by the Seagate Approved Package label Shipping a drive...

Страница 25: ...and blind mateable For installations which require cables users can connect the drive as illustrated in Figure 3 Figure 3 Attaching SATA cabling Each cable is keyed to ensure correct orientation Barr...

Страница 26: ...tandard documented in SFF 8301 and SFF 8323 found at www sffcommittee org Note The image is for mechanical dimension reference only and may not represent the actual drive 3 750 010 2X 1 625 020 1 432...

Страница 27: ...10 3 750 010 1 432 019 2 128 010 814 020 2 C L OF DRIVE C L OF CONN 4X 6 32 UNC 2B 3 MIN THREAD DEPTH 1 MAX FASTENER PENETRATION MOUNTING HOLES BOTH SIDES MAX TORQUE 6 IN LBS Y 5 787 MAX 146 99 MM 2X...

Страница 28: ...agate BarraCuda Pro v6 Serial ATA Product Manual Rev A 27 Figure 6 Mounting configuration dimensions 2TB Note The image is for mechanical dimension reference only and may not represent the actual driv...

Страница 29: ...e the ground pins P4 and P12 the pre charge power pins and the other ground pins the signal pins and the rest of the power pins 3 There are three power pins for each voltage One pin from each voltage...

Страница 30: ...eck Power Mode E5H Download Microcode 92H Execute Device Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Identify Device ECH Idle E3H Idle Immediate E1H NoP 00H Read Buffer E4H Read Buffer DM...

Страница 31: ...R T Save Attribute Values B0H D3H S M A R T Write Log Sector B0H D6H Standby E2H Standby Immediate E0H Trusted Send 5EH SED drives only Trusted Send DMA 5FH SED drives only Trusted Receive 5CH SED dri...

Страница 32: ...revision 8 ASCII character string padded with blanks to end of string x xx 27 46 Drive model number 40 ASCII characters padded with blanks to end of string 47 Bits 7 0 Maximum sectors per interrupt o...

Страница 33: ...163H 88 Ultra DMA support and current mode see note following this table 007FH 89 Security erase time xxxxH 90 Enhanced security erase time xxxxH 92 Master password revision code FFFEH 93 Hardware res...

Страница 34: ...dia Card Pass Through Command feature set is supported 4 Streaming feature set is supported 5 GPL feature set is supported 6 WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands are supported 7 WRITE...

Страница 35: ...Set transfer mode based on value in Sector Count register Sector Count register values 00H Set PIO mode to default PIO mode 2 01H Set PIO mode to default and disable IORDY PIO mode 2 08H PIO mode 0 0...

Страница 36: ...nnecessary drive returns The diagnostic software ships with all new drives and is also available at http www seagate com support downloads seatools This drive is shipped with S M A R T features disabl...

Страница 37: ...ited States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 1...

Отзывы: