VER 1.0
18Gbps 8
x
8 HDMI Matrix
with ARC Function
MS-HDM88
SEADA
Страница 1: ...VER 1 0 18Gbps 8x8 HDMI Matrix with ARC Function MS HDM88 SEADA ...
Страница 2: ...ical components that may be damaged by electrical spikes surges electric shock lighting strikes etc Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment 1 Introduction 2 Features 3 Package Contents 4 Specifications 5 Operation Controls and Functions 6 IR Remote 7 IR Cable Pin Assignment 8 EDID Management 9 Web GUI User Guide 10 RS 232 Cont...
Страница 3: ...CP 1 4 compliant Video resolution up to 4K2K 60Hz YUV 4 4 4 on all HDMI ports Support 18Gbps video bandwidth Dolby Vision HDR10 and HLG are supported Support 4K 1080P Down Scaler for each output port HDMI audio pass through up to 7 1CH HD audio LPCM Dolby TrueHD and DTS HD Master Audio Audio de embedded is supported via analog and coax ports ARC CEC and smart EDID management are supported 1U rack ...
Страница 4: ...e 8 Coax Audio RCA 8 L R Audio 3 5mm Stereo Mini jack Control Ports 1 TCP IP RJ45 1 RS 232 D Sub 9 Mechanical Housing Metal Enclosure Color Black Dimensions 440mm W 200mm D 44 5mm H Weight 2 8kg Power Supply Input AC 100 240V 50 60Hz Output DC 12V 5A US EU standard CE FCC UL certified Power Consumption 43W 10 C 45 C 14 F 113 F 20 C 60 C 4 F 140 F Operating Temperature Storage Temperature Relative ...
Страница 5: ...on again to confirm Baud rate setting On the initial OLED display screen press MENU button to enter the Baud rate interface and press UP DOWN button to select the required Baud rate finally press the ENTER button to confirm the setting IP Address Check On the initial OLED display screen press MENU button to enter the IP interface then press UP DOWN button to check the current IP address Pressing t...
Страница 6: ...udio output port connect to an amplifier or speaker via a 3 5mm audio cable Coaxial audio output port connect to audio output device such as audio amplifier via a coaxial cable TCP IP control port connect to PC or router with an RJ45 cable Connect to a PC or control system by D Sub 9 pin cable to transmit RS 232 command GND Connect the housing to the ground DC 12V Connect to 12V 5A power adapter 4...
Страница 7: ...output button firstly and then press input button to select the corresponding input source For example Press Output X X means output button from 1 to 8 including All button Then press Input Y Y means input button from 1 to 8 The Matrix can be selected input and output source by using the IR remote There are two ways to receive the IR remote signal The first way The IR window accepts the IR remote ...
Страница 8: ...g the IR remote is 7 meters and the IR remote is directly faced to the IR receiver head The diagram is shown as below 1 2 3 4 5 6 7 8 1 2 3 4 8 7 6 5 All HDMI Matrix Remote Input Output IR remote of the Matrix Machine Cabinet CONTROL TCP IP DC 12V RS 232 IR EXT OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 L R OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT ...
Страница 9: ...quired EDID and press the ENTER button A prompt copy to input will appear Then press UP DOWN button to select the input port you need to set and press ENTER button again to confirm this operation RS 232 control operation Connect the Matrix to PC with a serial cable then open a Serial Command tool on PC to send ASCII command s edid in x from z to set EDID For details please refer to EDID Setting in...
Страница 10: ...DTS 5 1 4K2K30_444 HD Audio 7 1 4K2K60_420 Stereo Audio 2 0 4K2K60_420 Dolby DTS 5 1 4K2K60_420 HD Audio 7 1 4K2K60_444 Stereo Audio 2 0 4K2K60_444 Dolby DTS 5 1 4K2K60_444 HD Audio 7 1 20 21 22 23 USER1 USER2 Copy from hdmi output 1 Copy from hdmi output 2 24 25 19 4K2K60_444 Stereo Audio 2 0 HDR 4K2K60_444 Dolby DTS 5 1 HDR 4K2K60_444 HD Audio 7 1HDR 26 27 28 29 Copy from hdmi output 5 Copy from...
Страница 11: ...he feedback information as shown below IP 192 168 62 109 in the above figure is the IP Address of the Matrix the IP address is variable depending on what the specific machine returns For the details of ASCII control please refer to 10 RS 232 Control Command Step 3 Input the IP address of the Matrix into your browser on the PC to enter Web GUI page After entering the Web GUI page there will be a Lo...
Страница 12: ...ice s OUTPUT port You can select signal source for it Input You can click the drop down menu to select signal source for the corresponding OUTPUT port Presets Name You can name the current scene with maximum length of 12 characters Presets Set You can restore the settings of the last saved audio video matrix switching relationship Presets Save You can save audio video matrix switching relationship...
Страница 13: ... EDID for the User Click the Browse button then select the bin file If you select the wrong EDID file there will be a prompt as shown in the following figure Make sure to select the correct file then you can check the name of the selected file Select User 1 or User 2 then click Upload After successful setting it will prompt as follows Download the EDID File of the Corresponding Input Channel Click...
Страница 14: ... port is connected to the display it shows green otherwise it shows gray Scaler Mode Set the current output resolution mode ARC Turn on off the ARC function Stream Turn on off the output stream 12 20 CEC Page You can perform CEC management on this page Input Control You can control the operation of each input source by clicking the icons on the page Output Control You can control the operation of ...
Страница 15: ... be a prompt as shown in the following figure Click OK to search the IP Address again as shown in the following figure After searching is completed it will switch to the login page the default network setting is completed 13 20 Website www seada co uk E mail sales seada co uk ...
Страница 16: ... the same as Old Password 3 New Password and Confirm Password must be the same Modify Network Setting Modify the IP Mode IP Address Gateway Subnet Mask Telnet Port as required click Save to save the settings then it will come into effect After modification if the IP Mode is Static it will switch to the corresponding IP Address if the IP Mode is DHCP it will automatically search and switch to the I...
Страница 17: ... Browse to select the update file then click Update to complete firmware update Factory Reset You can reset the unit to factory defaults by clicking Reset Reboot You can reboot the unit by clicking Reboot Note After reset reboot it will switch to the login page Then open a Serial Command tool on PC to send ASCII command to control the Matrix ASCII Command Serial port protocol Baud rate 115200 Data...
Страница 18: ... preset z Save switch state between all output port and the input port to preset z z 1 8 save to preset 1 s recall preset z Call saved preset z scenarios z 1 8 recall from preset 1 s clear preset z Clear stored preset z scenarios z 1 8 clear preset 1 r preset z Get preset z information z 1 8 video audio crosspoint Output Setting s in x av out y Set input x to output y x 1 8 y 0 8 0 all input 1 out...
Страница 19: ... Audio 7 1 16 4K2K60_444 Stereo Audio 2 0 17 4K2K60_444 Dolby DTS 5 1 18 4K2K60_444 HD Audio 7 1 19 4K2K60_444 Stereo Audio 2 0 HDR 20 4K2K60_444 Dolby DTS 5 1 HDR 21 4K2K60_444 HD Audio 7 1 HDR 22 User1 23 User2 24 31 copy from hdmi output 1 8 input 1 EDID 1080p Stereo Audio 2 0 all inputs EDID 1080p Stereo Audio 2 0 1080p Stereo Audio 2 0 Audio Setting r edid in x Get EDID status of the input x ...
Страница 20: ... input 1 stop operation s cec in x rew set input x rewind by CEC x 0 8 0 all input input 1 rewind operation s cec in x ff set input x fast forward by CEC x 0 8 0 all input input 1 fast forward operation s cec in x previous set input x previous by CEC x 0 8 0 all input input 1 previous operation s cec in x next set input x next by CEC x 0 8 0 all input input 1 next operation s cec hdmi out y off se...
Страница 21: ... network TCP IP port x 1 65535 Set TCP IP port 8000 s subnet xxx xxx xxx xxx Set network subnet mask Set subnet Mask 255 255 255 0 Please use s net reboot command or repower device to apply new config DHCP on Device can t config subnet mask set DHCP off first r subnet Get network subnet mask Subnet Mask 255 255 255 0 s gateway xxx xxx xxx xxx Set network gateway Set gateway 192 168 1 1 Please use ...
Страница 22: ...12V RS 232 IR EXT OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 L R OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 COAX OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 PC PC DVD or Blu ray Player TV box TV Monitor 2 0 Speakers Amplifier Power Supply The terms HDMI and HDMI High Definition Multimedia interface and the HDMI Logo are trademarks or registered...