1. INTRODUCTION

The 

CUBE

 R. NW is a vandal resistant keypad access control unit 

suitable for external applications. The unit accepts up to 500 users 

and provides entry via the use of PIN codes. 

Model 

CUBE

 R. NW is provided with LED backlight. 

2. MAIN TECHNICAL FEATURES

Operating Voltage Range:

12-24 VAC/DC 

Maximum Input Current: 

without heating:  

70mA in standby – 130 mA max 

with heating, 12Vcc: 
with heating, 24Vcc: 

Lock Strike Relay:
Auxiliary Relay:

550mA in standby – 610 mA max 
350mA in standby – 465 mA max 
2A 
2A 

Inputs

 

Main Input

 - BUTTON 1/BL

   N.O., Dry Contact 

 Auxiliary Input 

- BUTTON 2

    

 

N.C., Dry Contact in Monitor Mode 

 N.O., Dry Contact in Input Mode 

Operating Temperature

:

 Keypad Heater Enabled: 

 da –20 °C a 60 °C 

 Keypad Heater Disabled:      da 0 °C a 63 °C 

IP protection degree:

 IP 65 

Dimensions:

 120mm x 76mm x 22mm 

Weight:

 521 g 

Содержание CUBE R. NW

Страница 1: ...ange 12 24 VAC DC Maximum Input Current without heating 70mA in standby 130 mA max with heating 12Vcc with heating 24Vcc Lock Strike Relay Auxiliary Relay 550mA in standby 610 mA max 350mA in standby 465 mA max 2A 2A Inputs Main Input BUTTON 1 BL N O Dry Contact Auxiliary Input BUTTON 2 N C Dry Contact in Monitor Mode N O Dry Contact in Input Mode Operating Temperature Keypad Heater Enabled da 20 ...

Страница 2: ...allation Kit An L Shaped tool is provided for use when tightening the security screw 3 1 Wiring the CUBE R NW The controller is supplied with a 1 m pigtail having a 10 conductor cable To wire the CUBE R NW perform the following steps 1 Prepare the controller cable to the required length 2 Splice the controller pigtail wires to the corresponding devices and cover each connection Refer to the wire c...

Страница 3: ... NW Description Power supply 12 24V Ground BUTTON 1 BL BUTTON BL COM Main relay COM NC N C NO N O BUTTON2 IN Monitor COM Aux Relay COM NC N C NO N O 3 Trim and cover all conductors that are not used Two typical wiring diagrams are shown on the next pages ...

Страница 4: ...CUBE READER NW ENGLISH REV 00 4 3 2 Wiring the Lock to the Relay Optional Varistor ELECTRIC LOCK FAIL SAFE POWER SUPPLY 12V 24V AC DC BUTTON1 BL COM 1 NO 1 ...

Страница 5: ...CUBE READER NW ENGLISH REV 00 5 3 3 Wiring the Auxiliary Input and Output Optional Varistor COMMON POWER SUPPLY 12V 24V AC DC Auxiliary Relay IN MONITOR N C N O COM BUTTON 2 NO 2 NC 2 COM 2 ...

Страница 6: ... granted access when the CUBE R NW is in Normal or Bypass Mode Secure User A Secure User must have a Primary and Secondary Code programmed the two codes must not be the same The Secure User can gain access when the CUBE R NW is in any of its three Modes of Operation In Normal Mode the Secure User must use their Primary Code to gain entry In Secure Mode the Secure User must present both their Prima...

Страница 7: ...ike Relay is programmed for Fail Safe Operation or Fail Secure Operation When the Lock Strike Relay is programmed for Fail Secure Operation the door is locked until the Door Bell Button is pressed When the Lock Strike Relay is programmed for Fail Safe Operation the door is constantly unlocked 3 Secure Mode In secure mode the LED is red Only Secure and Master Users can access the premises during th...

Страница 8: ...actory setting for the Normal Secure Code 3838 1 Insert the code Mode LED will flash green 2 Press the key to confirm the Mode change the LED will turn green The CUBE R NW Auxiliary Input can also be used to switch the Mode of Operation from Normal to Secure and vice versa see par 13 5 1 3 Changing from Normal Mode to Bypass Mode To set the Normal Bypass code refer to par 14 1 Insert the code Mode...

Страница 9: ...oximity card or PIN code it is usually located in a convenient location e g Inside the door or at a receptionist s desk The function of the Exit button depends on whether the Lock Strike Relay is programmed for Fail Safe Operation or Fail Secure Operation 1 Fail Secure Operation From the moment the Exit button is pressed the door will be unlocked until the Lock Strike Release Time has passed After...

Страница 10: ...accepts as default a 4 digit sequence and in the same manner the access code for programming functions is of 4 digits default 1234 The number of digits can be increased to 5 6 or 8 digits This modification is made using menu 0 after having entered the programming mode see paragraph 23 ATTENTION this programming must be done at the time of installation because passing from one length to another can...

Страница 11: ...2341 123412 12341234 12 4 Change Normal Secure Code 3838 38383 383838 38383838 13 5 Change Normal Bypass Code 14 6 Change Door Release Time 0004 16 Define Auxiliary Inputs Outputs 2004 15 Enabling the built in keypad heater 3000 20 Changing the backlight and LED behavior 5100 9 7 Enroll Proximity Cards PIN Code or both 17 8 Delete Proximity Cards Or PIN Code 18 9 Code Assignment with Lock relay Au...

Страница 12: ...de The factory default Programming Code is 1234 If a Programming Code is not entered within 5 seconds the QUBE R NW will return to Normal Mode 8 2 To exit the Programming Mode 1 Press twice to exit Programming mode at any time You hear 3 beeps 2 The Door LED will be off and the Mode LED will turn green the QUBE R NW has returned to Normal Mode NOTE Wrong entries may reset the controller back to No...

Страница 13: ...t you wish to select see the following table The third and fourth digits are 0 4 System returns to Transmit Mode you will hear one beep the Door LED will turn off and the Mode LED will turn green WARNING In modes 2 and 3 backlight is actually turned off or dimmed 10 seconds after programming Backlight and LED mode Option number LED active backlight OFF 0 LED active backlight ON default 1 LED and b...

Страница 14: ...ult Open Code will automatically be deleted ready for a new Open Code to be re entered 1 Enter Programming Mode 2 Press 1 to enter Menu 1 The Mode LED will turn red 3 Insert the new Opening Code 4 The CUBE R NW returns to Normal Mode the Door LED will turn off and the Mode LED will turn green NOTE Open Code does not function in Secure Mode Wrong entries will return the controller to Normal Mode Co...

Страница 15: ...Mode LED will turn orange 3 Insert the new Auxiliary Code 4 The CUBE R NW returns to Normal Mode you will hear three beeps The Door LED will turn off and the Mode LED will turn green NOTE Auxiliary Code does not work in Secure Mode and only works when the Auxiliary Mode is 0 1 8 or 9 Code 0000 will erase and deactivate the Auxiliary Code 12 Changing the Programming Code 1 Enter Programming Mode 2 ...

Страница 16: ...ill turn off and the Mode LED will turn green NOTE When the Auxiliary Mode is 1 2 3 or 4 the Auxiliary Input takes priority over the Normal Secure Code 14 Changing the Normal Bypass Code 1 Enter Programming Mode 2 Press 5 to enter Menu 5 the Mode LED will flash orange 3 Insert a 4 digit code with 0 as the last digit for the selection of the by pass mode To cancel the access code to the by pass mod...

Страница 17: ...uts 1 Enter Programming Mode 2 Press 6 to enter Menu 6 the Mode LED will flash green 3 Construct the 4 digit code using the instructions below The system returns to Normal Mode The Door LED will turn off and the Mode LED will turn green GREEN GREEN GREEN Time Settings ...

Страница 18: ...ell Button N O 01 to 99 Aux Relay Release Time 00 Aux Relay Toggles 3 Normal Secure Tamper Event N C 01 to 99 Aux Relay Release Time 00 Aux Relay activated by Tamper 4 Normal Secure Direct Shunt N O 00 to 99 Shunt time 5 Door Monitor Shunt N C 00 to 99 Maximum Shunt Time 6 Door Monitor Forced Door N C 00 to 99 Forced Delay 7 Door Monitor Door Ajar N C 00 to 99 Ajar Delay 8 LED Ctrl Green Valid cod...

Страница 19: ... 12 second Lock Strike release time 17 Enrolling Primary Secondary Codes Primary Codes Primary Codes can only be enrolled to an empty User Slot i e a slot where there is no existing Primary Code Primary Codes must be unique i e one user Primary Code may not be the same as another user Primary Code Primary Codes cannot be the same as any system codes such as the Normal Secure Code or Open Code User...

Страница 20: ...r Slot number for the user you wish to program is known You can program both Primary and Secondary Codes using the Standard method B The Code Search Method is mainly used when enrolling a users Secondary Code and the User Slot Code is unknown The Code Search method only works if a user s Primary Code is already enrolled but the Secondary Code is not 17 1 Enrolling Primary and Secondary Codes using...

Страница 21: ...econdary Code you will hear a long beep and the controller will return to Normal Mode 4 Enter the 4 digit PIN that you want to assign as the Primary or Secondary Code for this slot number If the PIN that is entered is valid the Mode LED will stop flashing and then the controller is ready for you to enter the next 3 Digit slot number refer to step 3 that you want to assign a code to 5 Press the key...

Страница 22: ...id you will hear RED a long beep and the CUBE R NW will continue to wait for a valid Primary Code 5 Enter the 4 digit PIN Code to be used as the Secondary Code If the Secondary Code is valid the controller will beep three times and return to Normal Mode If the Secondary Code is invalid the controller will make a long beep and then the QUBE R NW will continue to wait for a valid Secondary code to b...

Страница 23: ...Code is invalid you will hear a long beep and the CUBE R NW will return to Normal Mode 18 2 Deleting Primary and Secondary Codes using the Code Search Method 1 Enter Programming Mode 2 Press 8 to enter Menu 8 the Mode LED will turn red 3 Enter the 3 digit User Slot 000 the Door LED will flash orange 4 Enter the 4 digit PIN Code of the Primary Code belonging to the user you want to delete the Mode ...

Страница 24: ...od and the Code Search Method 19 1 Relay Code Assignment using the Standard Method 1 Enter Programming Mode 2 Press 9 to enter Menu 9 the Mode LED will turn green 3 Enter the 3 digit User Slot that you want to assign a code to The Mode LED will flash green 4 Enter the assignment digit for the current User Slot 1 assigns the Lock Strike Relay only 2 assigns the Auxiliary Strike Relay only 3 assigns...

Страница 25: ...Relay 6 If the assignment digit is valid three beeps are heard and the controller returns to Normal mode If the assignment digit is invalid a long beep sounds and the controller waits for another assignment digit to be entered 20 Enabling or Disabling the built in keypad heater The CUBE R NW contains a built in keypad heater When is enabled the keypad heater will activate when the ambient temperat...

Страница 26: ...s the EXIT BUTTON button 3 Apply power to the unit with EXIT button pressed 4 Release the EXIT button 5 Within 15 seconds enter programming mode by pressing twice insert the default programming code see table in paragraph 8 Press 3 to access the programming code modification function Enter the new programming code 6 The CUBE R NW returns to Normal mode the Door LED switches off and the Mode LED tu...

Страница 27: ...Menu 0 3 Press the number corresponding to the desired length of the code 0 4 digits 5 5 digits 6 6 digits 8 free length from 4 to 8 digits in this mode when a code with less than 8 digits is input it must be confirmed by pressing the key Both the LED will flash red 4 Insert the programming code If the Programming Code is valid all memory will be erased you will hear three beeps and the controller...

Отзывы: