Aqua Whisper DX Modular 450-1800
Page 6-1
Commissioning
If the Reverse Osmosis Membrane Element has been
installed, there will be a Reverse Osmosis Membrane
Element Serial Number tag, attached to the High
Pressure Vessel.
If the R.O. Membrane Element Serial Number tag is
missing or does not contain a serial number and date,
then immediately contact the company that sold the
system to you, the installer, or Sea Recovery.
WARNING
! DO NOT attempt to operate
the system without a Reverse Osmosis
Membrane Element installed in the system
otherwise extensive damage will result.
WARNING
! Damage caused to the
system due to operation of the System
without an R.O. Membrane Element
correctly installed is the liability of the
installer and the operator.
6.3 SETUP CONTROLLER
The controller is set by Sea Recovery prior to shipping
based on the features and optional equipment that
shipped with the System at the time of ordering.
Addition of the Fresh Water Flush to the System after it
has shipped from Sea Recovery will require new set up
of the computer logic.
Addition of, removal of, or changes in the length of the
R.O. Membrane / Pressure Vessel Assembly will require
control logic setup. Refer to the NMEA Configuration Guide.
6
COMMISSIONING
COMMISSIONING NOTES
These Commissioning instructions must be carried out
for initial start-up of a NEW system.
Failure to follow these instructions will lead to system
failure and cause damage to components.
6.1 CHECK INSTALLATION
Ensure that the installation has been properly performed.
Do not rely on the installer’s word, do not assume the
System has been installed correctly.
WARNING
: Damage caused to the
system due to operation of an improperly
installed system is the liability of the
installer and the operator.
Check each water connection to the system to ensure
that the installer has properly connected and properly
routed each tube. Improper routing and any blockage
in any line causes damage to the system. Improperly
connected or loose connected lines resulting in leaks
causing damage is the liability of the installer and the
operator, and is not covered by the Sea Recovery warranty.
Do not assume and do not rely on the installer’s word;
check it yourself.
Make sure that the Electrical Power Source, boat’s circuit
breaker to the system, is switched “OFF”.
Open the unit cover and check all electrical and
electronic connections for proper wiring and attachment.
After checking all wiring for correct and tight connection,
close the cover.
Switch the Electrical Power Source, boat’s circuit breaker
to the system, to the “ON” position.
6.2 CHECK RO MEMBRANE
Check to ensure that the Reverse Osmosis Membrane
Elements are installed within the Pressure Vessels.
CAUTION
: Some systems are
shipped WITHOUT the Reverse
Osmosis Membrane Element. This is
to accommodate Boat Builders that
install the system well in advance of
commissioning the System.
Aquawhisper
Содержание Aqua Whisper DX 1400-2
Страница 2: ......
Страница 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...
Страница 4: ......
Страница 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...
Страница 12: ...Introduction...
Страница 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...
Страница 16: ...Description...
Страница 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...
Страница 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...
Страница 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...
Страница 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...
Страница 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...
Страница 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...
Страница 40: ...Pre installation...
Страница 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...
Страница 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...
Страница 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...
Страница 66: ...Electrical...
Страница 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...
Страница 80: ...Electrical...
Страница 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...
Страница 82: ...Installation...
Страница 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...
Страница 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...
Страница 96: ...Commissioning...
Страница 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...
Страница 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...
Страница 108: ...Operation...
Страница 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...
Страница 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...
Страница 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...
Страница 124: ...Maintenance...
Страница 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...
Страница 146: ...Troubelshooting...
Страница 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...
Страница 168: ...Parts View...
Страница 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...
Страница 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...
Страница 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...
Страница 218: ...Sheet 11 4 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase with Soft Start...
Страница 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...
Страница 220: ...Sheet 11 6 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase with Soft Start...
Страница 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...
Страница 222: ...Sheet 11 8 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase with Soft Start...
Страница 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...
Страница 224: ...Sheet 11 10 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase with Soft Start...
Страница 225: ......