Aqua Whisper DX Modular 450-1800
Page 6-6
Commissioning
7.
Touch the HP Pump START button.
8.
Slowly increase operating pressure by adjusting
the back pressure regulator valve knob in a
clockwise direction until the product water flow
reaches the System production rate.
a) If the high pressure exceeds 975 psi (67 bar),
an alarm will sound and shut down the System.
b) When production rate is reached, the System
will start monitoring the product water salinity.
Although the system is producing “Product
Water”, the Product Water may not be
“Potable” for up to 30 minutes. The salinity of
the Product Water diminishes gradually, until
it reaches the acceptable level or lower.
PRODUCT SALINITY (RED) simply means that the
dissolved solids in the Product Water have not yet
decreased to acceptable level.
PRODUCT SALINITY (GREEN) simply means that
the dissolved solids in the Product Water have
reached the acceptable level and the Diversion
Valve can be activated.
9.
Activate the Diversion valve when Salinity meter
turns Green.
a). If the tank is not full and the salinity of the
product water drops below the preset salinity
level, the U.V. sterilizer will energize if installed.
b) Feed Pressure, Feed Flow, Operating Pressure,
Brine Flow, Product Flow, and Product Salinity
will be monitored and the System Control
Logic will perform various tasks to maintain
proper functioning of the System.
c). When the tank is full, the System will
stop all operations.
10. Check for:
a) A constant feed water flow.
b) A consistent system pressure.
c) Leaks in the system.
d) Abnormal noises or other occurrences.
11. If any abnormality develops, touch the STOP button
on the Touch Screen. A warning screen will display.
a) Correct the problem then repeat Step 1-10.
12. Proceed to Log System Readings.
3-way Diversion Valve will energize sending
the product water to the potable water outlet.
e) Feed Pressure, Feed Flow, Operating Pressure,
Brine Flow, Product Flow, and Product Salinity
will be monitored and the System Control
Logic will perform various tasks to maintain
proper functioning of the System.
f). When the tank is full, the System will stop
all operations.
5.
Check for:
a) A constant feed water flow.
b) A consistent system pressure.
c) Leaks in the system.
d) Abnormal noises or other occurrences.
6.
If any abnormality develops, a warning/error
screen will display.
a) Stop the System. correct the problem then
repeat Step 1-5.
7
.
Proceed to Log System Readings.
B. MANUAL MODE
The Manual Mode is intended for SRC technicians for
setup and configuration purposes.
NOTE
: The Remote Touch Screen will
be blocked during operation in the
Manual Mode.
CAUTION
: When the System is operated
in the MANUAL Mode Safety features will
still be controlled by the System Logic,
however AUTOMATED features will not
be controlled by the System Logic and
must be controlled by the operator.
1.
Verify the back pressure regulator valve knob is in
fully open position.
2.
From the default screen, touch the SETUP tab.
3.
On the next screen, touch the Acceptable Salinity
Level button.
4.
On the Salinity Level screen, adjust to desired level
(200 to 1000 PPM) then touch the SETUP button.
5.
On the next screen, touch the Manual Mode button.
6.
On the next screen, touch the Booster Pump
START button then wait 5 seconds for booster
pump to stabilize.
Содержание Aqua Whisper DX 1400-2
Страница 2: ......
Страница 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...
Страница 4: ......
Страница 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...
Страница 12: ...Introduction...
Страница 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...
Страница 16: ...Description...
Страница 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...
Страница 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...
Страница 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...
Страница 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...
Страница 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...
Страница 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...
Страница 40: ...Pre installation...
Страница 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...
Страница 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...
Страница 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...
Страница 66: ...Electrical...
Страница 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...
Страница 80: ...Electrical...
Страница 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...
Страница 82: ...Installation...
Страница 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...
Страница 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...
Страница 96: ...Commissioning...
Страница 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...
Страница 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...
Страница 108: ...Operation...
Страница 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...
Страница 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...
Страница 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...
Страница 124: ...Maintenance...
Страница 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...
Страница 146: ...Troubelshooting...
Страница 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...
Страница 168: ...Parts View...
Страница 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...
Страница 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...
Страница 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...
Страница 218: ...Sheet 11 4 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase with Soft Start...
Страница 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...
Страница 220: ...Sheet 11 6 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase with Soft Start...
Страница 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...
Страница 222: ...Sheet 11 8 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase with Soft Start...
Страница 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...
Страница 224: ...Sheet 11 10 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase with Soft Start...
Страница 225: ......