Aqua Whisper DX Modular 450-1800
Page 6-5
Commissioning
6.6.3 START THE SYSTEM
A. SEMI-AUTOMATIC MODE
The Semi-Automatic Mode is recommended for users
and owners. These instructions are recommended when
the System is configured with a Tank High Level sensor.
1.
Verify the back pressure regulator valve knob is in
full open position.
2.
Press the Start button on the Main Control Panel or
Remote Control Panel.
a) The System starts monitoring the Tank level,
system pressures, and system water flow.
b) The System starts the booster pump.
c) When the inlet pressure of the high pressure
pump is within 35 psi (2.4 bar) for 20 seconds,
the System starts the high pressure pump.
3.
Verify that the low pressure gauge reading is
within 35 psi (2.4 bar), normal operating range.
4.
Slowly increase operating pressure by adjusting
the back pressure regulator valve knob in a
clockwise direction until the product water flow
reach the System production rate.
a) If the high pressure exceeds 975 psi
(67.2 bar), an alarm will sound and shut
down the System.
b) When the production flow rate is reached,
the System will start monitoring the product
water salinity.
Although the system is producing “Product
Water”, the Product Water may not be “Potable”
for up to 30 minutes. The salinity of the Product
Water diminishes gradually, until it reaches the
acceptable level or lower.
PRODUCT SALINITY (RED) simply means that the
dissolved solids in the Product Water have not yet
decreased to acceptable level.
PRODUCT SALINITY (GREEN) simply means that
the dissolved solids in the Product Water have
reached the acceptable level and the Diversion
Valve can be activated.
c). If the tank is not full and the salinity of the
product water drops below the preset salinity
level, the U.V. sterilizer will energize if installed.
d) If the salinity of the product water is below
the preset salinity level for 5 seconds the
6.6.2 APPLY POWER TO THE SYSTEM
a) Switch the Electrical Power Source, boat or
home’s circuit breaker to the system “ON”.
b) All Operating Screens WILL NOT include the
Automatic Fresh Water Flush components if
the Fresh Water Flush Option is not installed
and the control logic has been informed that
the Fresh Water Flush Option is not installed.
c) After the control logic has initiated itself, the
default screen will appear indicating that the
System is ready to Start.
Aquawhisper
Fig. 6a: Default screen
Figure 6e: Valves positioned for
Media Filter Rinse
Figure 6f: Valves positioned for
Normal Operation
Figure 6d: Valves positioned for
Media Filter Backwash
Содержание Aqua Whisper DX 1400-2
Страница 2: ......
Страница 3: ...Aqua Whisper DX Modular 450 1800 Owner s Manual...
Страница 4: ......
Страница 11: ...Introduction Aqua Whisper DX Modular 450 1800 Section 1 INTRODUCTION...
Страница 12: ...Introduction...
Страница 15: ...Description Aqua Whisper DX Modular 450 1800 Section 2 SYSTEM DESCRIPTION...
Страница 16: ...Description...
Страница 21: ...Aqua Whisper DX Modular 450 1800 Page 2 5 Description COMPLIANCE CERTIFICATES...
Страница 23: ...Aqua Whisper DX Modular 450 1800 Page 2 7 Description...
Страница 25: ...Aqua Whisper DX Modular 450 1800 Page 2 9 Description...
Страница 30: ...Aqua Whisper DX Modular 450 1800 Page 2 14 Description OPTIONAL ACCESSORIES...
Страница 38: ...Aqua Whisper DX Modular 450 1800 Page 2 22 Description This page is intentionally left blank...
Страница 39: ...Aqua Whisper DX Compact 450 1800 Section 3 PRE INSTALLATION NOTES Pre installation...
Страница 40: ...Pre installation...
Страница 56: ...Aqua Whisper DX Modular 450 1800 Page 3 16 Pre installation...
Страница 57: ...Aqua Whisper DX Modular 450 1800 Page 3 17 Pre installation...
Страница 65: ...Aqua Matic Compact 450 1800 Section 4 ELECTRICAL INFORMATION Electrical...
Страница 66: ...Electrical...
Страница 75: ...Aqua Whisper DX Modular 450 1800 Page 4 9 Electrical Electrical Motor Wiring Three Phase...
Страница 80: ...Electrical...
Страница 81: ...Installation Aqua Whisper DX Modular 450 1800 Section 5 INSTALLATION REQUIREMENTS...
Страница 82: ...Installation...
Страница 94: ...Aqua Whisper DX Modular 450 1800 Page 5 12 Installation...
Страница 95: ...Commissioning Aqua Whisper DX Modular 450 1800 Section 6 COMMISSIONING...
Страница 96: ...Commissioning...
Страница 106: ...Aqua Whisper DX Modular 450 1800 Page 6 10 Commissioning...
Страница 107: ...Operation Aqua Whisper DX Modular 450 1800 Section 7 OPERATION...
Страница 108: ...Operation...
Страница 120: ...Aqua Whisper DX Modular 450 1800 Page 7 12 Operation...
Страница 122: ...Aqua Whisper DX Modular 450 1800 Page 7 14 Operation...
Страница 123: ...Aqua Whisper DX Compact 450 1800 Section 8 MAINTENANCE AND REPAIR Maintenance...
Страница 124: ...Maintenance...
Страница 145: ...Troubelshooting Troubelshooting Aqua Whisper DX Modular 450 1800 Section 9 TROUBLESHOOTING...
Страница 146: ...Troubelshooting...
Страница 167: ...Parts View Aqua Whisper DX Modular 450 1800 Section 10 EXPLODED PARTS VIEW...
Страница 168: ...Parts View...
Страница 183: ...Aqua Whisper DX Modular 450 1800 Page 10 15 Parts View...
Страница 191: ...Aqua Whisper DX Modular 450 1800 Page 10 23 Parts View...
Страница 217: ...Sheet 11 3 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase...
Страница 218: ...Sheet 11 4 Aqua Whisper DX Electrical Wiring Diagram 110 120 VAC 50 60 HZ Single Phase with Soft Start...
Страница 219: ...Sheet 11 5 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase...
Страница 220: ...Sheet 11 6 Aqua Whisper DX Electrical Wiring Diagram 208 240 VAC 50 60 HZ Single Phase with Soft Start...
Страница 221: ...Sheet 11 7 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase...
Страница 222: ...Sheet 11 8 Aqua Whisper DX Electrical Wiring Diagram 200 240 VAC 50 60 HZ Three Phase with Soft Start...
Страница 223: ...Sheet 11 9 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase...
Страница 224: ...Sheet 11 10 Aqua Whisper DX Electrical Wiring Diagram 380 460 VAC 50 60 HZ Three Phase with Soft Start...
Страница 225: ......