TRANSFORMER

FIGURE 1

120V 
QUICK-CONNECT PLUG

INSTALLING SWITCH ON 120V CORD

INSTALLATION OF 120V QUICK-CONNECT PLUG

INSTALLATION AND SAFETY INSTRUCTIONS

HC-342

NOTE: Switch must be mounted a least 1 1/2” away from
any metal parts.

NOTE: When parallel wire (SPT II) is used, the tracer wire
is square shaped or ridged and the non-tracer wire is
round in shape or smooth (seen best when viewed from
wire end).

1. Split 120v cord as illustrated (FIGURE 3). Cut the 

non-tracer (or smooth) wire. Be sure to cut only the
smooth non-tracer wire.

2. Remove the screw from the switch and take the switch

apart.

3. Place the wires in part A (without the wheel) as shown.

Tuck the cut wire down one end on each side of the 
barrier.

4. Press both halves of the switch back together. Note that

the points pierce insulation to make contact with copper
inside wire.

5. Place screw back into center hole and secure in place

with nut.

1. Cut off end of 120v cord cleanly and evenly. CAUTION: Do

not separate wires. Do not remove or damage 
insulation (Figure 2).

2. Press cord, with ridged side to the right (tracer wire),

down and into front of plug.

3. Press cord down onto metal prongs.

4. Slide plug cover over cord and plug until  plug cover is

centered over  plug.

120V SWITCH

TRANSFORMER

120V CORD

120V 
QUICK-
CONNECT
PLUG

SWITCH

POINTS

PART A

SCREW

NUT

NON-TRACER WIRE

TRACER WIRE

COVER

120V
CORD

120V
CORD

FIGURE 2

FIGURE 3

PLUG
(IF APPLICABLE)

WARNING: Be sure the electricity to the wires you are 
working on is shut off; either the fuse removed or the circuit
breaker off.
For this transformer to operate the wattage load must be a
minimum of 60w, but must not exceed 150w.

INSTRUCTIONS FOR INSTALLATION OF THE
AMBIANCE™ ACCENT TRANSFORMER

COVER 
PLATE (C)

FIGURE 4

051904

120V TERMINAL
SCREWS (E)

MOUNTING TAB (B)

12V TERMINAL
SCREWS (G)

TRANSFORMER INSTALLATION

Select the desired location to mount the transformer (A) (not
in contact with insulation & away from oven or any other
source of intense heat including transformer).  Using the two
screws (provided), fasten the transformer and mounting tab to
the mounting surface.  Remove the cover plate (C) from the
transformer body.  Identify the two terminals for the line volt-
age (120V) and the low voltage (12V) side.  This is identified
from both the cover plate (C) and the transformer label (D).

TRANSFORMER
LABEL (D)

TRANSFORMER (A)

FOR PROPER OPERATION OF AN ELECTRONIC 

TRANSFORMER, THE WATTAGE LOAD MUST FALL

WITHIN THE SPECIFIED RANGE. IF THE LOAD DOES NOT 

FALL WITHIN THIS RANGE, THE TRANSFORMER MAY

MALFUNCTION OR LAMPS MIGHT FLICKER. 