Section 08
ELECTRICAL SYSTEM
Sub-Section 02
(IGNITION SYSTEM)
08-02-13
DC-CDI Module Verification
STATIC TEST
: CONTINUITY
Multi-Purpose Electronic Module
(MPEM) Verification
STATIC TEST
: CONTINUITY
The multi-purpose electronic module testing must
be done with all wires disconnected from circuit.
Otherwise testing equipement (ohmmeter) could
be damaged.
NOTE :
<
=
less than
>
=
greater than
Holder Relay Verification
STATIC TEST
: CONTINUITY
1. Disconnect the PURPLE
/
BLUE and BLACK
wires coming out from the holder relay.
2. Connect meter leads to above wires and resis-
tance of holding coil should be 104 ohms
(
±
10%).
DYNAMIC TEST
1. Disconnect all 4 wires to the holder relay.
2. Set meter to resistance scale, connect meter
leads to RED
/
BLUE and RED
/
PURPLE wires
(there should be no reading).
3. Jumper DC (battery) voltage
: positive lead to
PURPLE
/
BLUE, negative to BLACK.
4. By energizing the coil, the switch should have
closed, the ohmmeter should read less than 0.5
ohm resistance.
+ Meter Lead
- Meter Lead
Value
RE/PU
BK
2.6 k
Ω
YL/WH
BK
0.380 M
Ω
WH
BK
2.208 M
Ω
BK/OR
BK
infinity
BK/GR
BK
infinity
BK
BK
0.2
Ω
WH/BL
BK
30.38
k
Ω
BK
RE/PU
2.690 k
Ω
BK
YL/WH
0.390 M
Ω
BK
WH
2.2 M
Ω
BK
BK/OR
infinity
BK
BK/GR
infinity
BK
BK
2.69 k
Ω
BK
GY/WH
33.07 k
Ω
+ Meter Lead
- Meter Lead
Value
RE/PU
(male connector)
RE
< 1
Ω
RE/PU
(male connector)
RE/PU
(female connecto)
< 1
Ω
RE/PU
(male connector)
BK
(ring terminal)
> 20 k
Ω
WH/GY
BK
(ring terminal)
> 100 k
Ω
TA/BL
BK
(ring terminal)
> 10 k
Ω
PU/WH
BK
(ring terminal)
> 2 k
Ω
> 2.4
Ω
YL/RE
(female connector)
BK
(ring terminal)
> 10 k
Ω
YL/RE
(male connector)
BK
(ring terminal)
> 50 k
Ω
GY/WH
BK
(ring terminal)
> 9 k
Ω
< 11
Ω
WH/BL
BK
(ring terminal)
> 4.3 k
Ω
< 4.9 k
Ω
WH/BL
PU/WH
> 2.2 k
Ω
< 2.6 k
Ω
BK
(ring terminal)
RE
(ring terminal)
> 10 k
Ω
www.SeaDooManuals.net