3 Step Instruction for
the L.E.D. Lights
Step 1:
The SK-103LE Alarm Module Lights
YELLOW-
Power Test Light (at front left)
• If this light flashes every 15 seconds:
Batteries are good
• If this light flashes and simultaneously
the horn sounds twice:
Batteries need to be replaced
• If this light flashes and simultaneously
the horn sounds twice continually:
There are NO BATTERIES-
horn will continue to chirp until installed
GREEN-
Circuit Test Light (at front right)
• If this light is lit, this indicates an open circuit, and horn will sound if system is “ON”.
A Sensor, Strip or Splitter has been disconnected or a connection is not complete.
Step 2:
Splitter Box & Strip Lights
GREEN- Sensor Port Lights
• If this light is lit, and No Sensor is plugged into the port: Insert a “Shunt Plug”,
and re-set the alarm.
• If this light is lit, and a Sensor is plugged in to that port, the Sensor connected
to the port is disconnected or ajar from the product.
• If this light is dark: The Sensor is connected properly.
Step 3:
Sensor Lights
WHITE-
If this light is not lit, it indicates that the sensor is Not Plugged In
GREEN-
If this light is lit and GREEN, it indicates that the Sensor is connected
to a Splitter Box or Strip, but not connected properly to the product.
RED-
If this light is lit and RED, it indicates that the Sensor is connected properly
to the product, and actively protecting the product.
L.E.D.
Lights
Circuit Test
Power Test
L.E.D. Lights Changes Color
WHITE: Not Connected to a Splitter or Strip
GREEN: Not Connected to Product
RED:
Connected Properly
GREEN- Sensor Port Lights