- 52 -
Make sure to test the operation of KS06 after installation to verify that KS06 operates as intended.
Make sure to stop the machine until the test is complete. Unintended function settings may cause a
person to go undetected, resulting in serious injury.
WARNING
Section3 Check and debugging
After installation, the highest level administrator must use the following checklist to verify the
operation, placing a check mark in each of the boxes.
3.1.Installation condition check
□ The machine itself does not prevent the operation of safety functions such as stopping.
□ The hazardous part of a machine cannot be reached without passing through the detection zone of KS06.
□ KS06 can always detect a worker who is working in the hazardous zone.
□ Safety distance has been calculated. Calculated distance: S = mm.
□ The actual distance is equal to or greater than the calculated distance. Actual distance = mm.
□ Reflective objects are not installed in prohibited zones.
□ It can’t be used in flammable or explosive atmosphere.
3.2.Wiring check before power is turned on
□ Power supply unit must be dedicated to KS06. It must have tolerance against total rated current of
devices if it is connected to multiple devices.
□ The power supply unit is a 24V DC unit that conforms to the EMC Directive, Low-voltage Directive,
and output holding specifications.
□ The power supply polarity is not connected in reverse.
□ Emitter/receiver cables are properly connected to the respective emitters/receivers, and the signal cables
are connected correctly.
□ Double insulation or reinforced insulation is used between I/O lines and the hazard potential (dangerous
power supplies, etc.).
□ Loads are not connected to the 24V DC line.
□ OSSDs are not short-circuited to 24V DC line.
□ All lines are not connected to dangerous power source.
□ Specification of emitter and receiver must be the same.
□ When 2 or more sets of KS06 are used, mutual interference prevention measures are taken.
□ AUX can not be used as safety output.
□ Power supply's 0V and the shielding layer must be grounded.
□ Use transmission cables prepared by KELI, and the length of the cables can’t exceed the specified value.
□ Neither connectors nor terminals can be loose.
□ Cables must not be bent, cracked, or damaged. The cables in the connector end should be relaxed to
avoid damaging the connectors.
3.3.Operation check while the machine is stopped
□The diameter is consistent with the detection capability of KS06.
When the test rod enters into the detection zone, KS06 light curtain retains light-shaded state; after
the test rode leaves the detection zone, the light curtain turns into light-passing state.
Move the test rod slowly through the protective field to be tested, as shown in figure
①
, the red
OFF-state indicator on the receiver is on.
Содержание KS06 AOPD Series