- 29 -
Section2 Installation and wiring
Please read the warnings carefully before installing, to avoid faulty installation which may cause
personal injury.
2.1 Installation requirements
WARNING
Make sure that the machine is OFF while installing, failure to do so may resulting in serious injury.
Do not use this sensor for machines that cannot be stopped by electrical control. For example, do
not use it for a pressing machine that uses a full-rotation clutch. Otherwise, the machine may not
stop before a person reaches the hazardous part, resulting in serious injury.
Install the sensor system so that it is not affected by the reflective surface, otherwise, may affect
the normal detecting function, resulting in serious injury.
Do not use KS06 in flammable and explosive environment, otherwise, it may cause explosion.
Make sure that foreign material such as water, oil, or dust does not enter the KS06 or the connector
while the cap is removed.
When using a wireless device such as a mobile phone or a radio transceiver near the product, make
sure to check that the product is not affected by electromagnetic waves generated by the wireless
device and that it can work normally.
If this product is used in an air medium with heavy smoke or fine particles or a corrosive chemical,
it may result in a decline in product quality.
The KS06 cannot protect a person from an object flying from a hazardous zone. Install protective
cover(s) or fence(s).
2.1.1 Detection zone and installation method
WARNING
Install a protective structure so that the hazardous part of a machine can only be reached by passing
through the sensor's detection zone. Install the sensors so that part of the person is always present
in the detection zone when working in a machine's hazardous zones.
If a person is able to step into the hazardous zone of a machine and remain behind the KS06's
detection zone, take some other measures to prevent the machine from being restarted. Failure to
do so may result in serious injury.
Do not use the sensor system with mirrors in a retro-reflective configuration as shown in Fig2.1,
Doing so may hinder the normal detection.
Fig 2.1 Reflector Constitutes a Schematic Diagram of the Transmitting System.