- 17 -
1.3 Technical parameters
Sheet 1.4 Technical parameters of CPSII/CQ2
Supply voltage
AC100V
to
230V,50/60HZ
DC24V±10%
Temperature
Operating
:
-10
℃~
55
℃
Storage
:
-40
℃~
70
℃
Humidity
Operating
:
35%RH
~
85%RH
Storage
:
35%RH
~
95%RH
Output
Relay contact output
Output contact capacity
5A,AC250V/DC30V
(
Resistive load)
)
Power consumption
<
15W
Response time
<
18ms
Dielectric strength
AC1500V, no arcing and flashover in 60s
Insulating resistance
>
100MΩ
Performance life of relay
≥1000000 times
IP code
CPS
Ⅱ
:IP54
CQ2:IP20
Safety class
Executed standards
IEC 61496-1(Type 4);IEC 61496-2(Type 4);ISO 13849-1(Cat. 4
、
PL e)
EN 61326-1; ISO 13855
Safety level
Type 4 Category 4 PL e
DCavg
99%
CCF
100
MTTF
D
/PFH
D
(
See parameter table
)
Optical characteristics
Light source
Infrared LED
(
940nm wavelength
)
Beam spacing(mm)
10mm
20mm
30mm
40mm
Detection capability
18mm
28mm
38mm
48mm
No. of beams
12
、
16…72
6
、
8…72
6
、
8…72
4
、
6…72
4
、
6…16
18
、
20…40
Operating range
A
:
0 to 6m
,
B
:
0 to 12m
,
D
:
0 to 20m
E
:
0 to 40m
E
:
0 to 30m
Protection height
Beam spacing × (number of beams-1)
EAA
Within ±2.5° for the emitter and receiver at a detection distance of at least 3m according to IEC 61496-2
Environment
Temperature
Operating
:
-10
℃~
55
℃
Storage
:
-40
℃~
70
℃
Humidity
Operating
:
35%RH
~
85%RH
Storage
:
35%RH
~
95%RH
Enclosure rating
IP65
Resistance to light
interference
Incandescent lamp:
3000 Lux
Fluorescent lamp:
3000 Lux
Sunlight: 10000Lux
Dimensions
52×36×Jmm (J is the length of emitter/receiver)
Electrical characteristics
Supply voltage
KS06
:
DC 12V ± 10%
KS06G
:
DC 24V ± 10%
Response time
KS06
:<
18 ms
KS06G
:<
18 ms
Current consumption Emitter
:<
300 mA
Receiver
:<
100 mA
Output characteristic
KS06
Output 4kHz square wave signal, driving current 10mA
KS06G
PNP
PNP transistor outputs×2 (OSSD is in ON-state when light curtain
is unblocked), load current 300mA max, Residual voltage 3V max.
(except for voltage drop due to cable extension)
NPN
NPN transistor outputs×2 (OSSD is in ON-state when light curtain
is unblocked), load current 300mA max, Residual voltage 3V max
(except for voltage drop due to cable extension)
Sheet 1.5 Technical parameters of KS06G/KS06 AOPD